文献速递胸部CT

Lung-RADS的阅片者间一致性:系统综述与Meta分析

Interreader Agreement of Lung-RADS: A Systematic Review and Meta-Analysis.
PubMed 文献 · AJR Am J Roentgenol · 2025-06-18

该系统综述与Meta分析纳入11项研究(1470例患者)评估Lung-RADS分类的阅片者间一致性,汇总κ=0.72(95%CI 0.57-0.82),属于实质性一致;另纳入5项研究(617例患者)评估结节大小测量的ICC=0.97(95%CI 0.90-0.99),属于几乎完全一致。结节测量方法、结节类型分布、辐射剂量和Lung-RADS版本均与一致性显著相关。

要点

  • Lung-RADS分类的汇总阅片者间一致性为κ=0.72(95%CI 0.57-0.82),属实质性一致。
  • 结节大小测量的汇总ICC=0.97(95%CI 0.90-0.99),属几乎完全一致。
  • CAD半自动体积测量、实性结节比例高、标准剂量CT及Lung-RADS 1.1版对应更高一致性。

核心结论

  • 结果支持Lung-RADS的总体可靠性,同时提示CAD辅助、培训及结节类型特征标准化方法有助于进一步促进其可重复应用。

研究设计与样本

  • 系统综述与Meta分析,检索Embase、PubMed和Cochrane数据库截至2024年6月18日发表的原始研究,采用随机效应模型计算汇总κ系数和ICC,并用Meta回归探索异质性来源。

诊断标准与关键数值

  • Lung-RADS分类的汇总阅片者间一致性κ=0.72(95%CI 0.57-0.82)。
  • 结节大小测量的汇总ICC=0.97(95%CI 0.90-0.99)。
  • 按结节测量方法分层:CAD半自动体积测量κ=0.95、CAD半自动直径测量κ=0.91、手动直径测量κ=0.66(p=.005)。
  • 按结节类型分布分层:100%实性结节κ=0.85、30-99%实性结节κ=0.76、少于30%实性结节κ=0.55(p<.001)。
  • 按辐射剂量分层:标准剂量CT ICC=0.97、低剂量CT ICC=0.96、超低剂量CT ICC=0.59(p<.001);按版本分层:Lung-RADS 1.1 ICC=0.99、Lung-RADS 1.0 ICC=0.93(p=.02)。

临床应用与阅片要点

  • 采用CAD半自动体积测量、标准剂量CT及Lung-RADS 1.1版时阅片者间一致性更高。
  • 实性结节比例低的病例及手动直径测量时一致性较低,报告时需注意。
  • 作者认为CAD辅助、培训及结节类型特征标准化方法可进一步促进Lung-RADS的可重复应用。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND. Lung-RADS has shown variable interreader agreement in the literature, in part related to a broad range of factors that may influence the consistency of its implementation. OBJECTIVE. The purpose of this study was to assess the interreader agreement of Lung-RADS and to investigate factors influencing the system's variability. EVIDENCE ACQUISITION. The Embase, PubMed, and Cochrane databases were searched for original research studies published through June 18, 2024, that reported the interreader agreement of Lung-RADS on chest CT. Random-effects models were used to calculate pooled kappa coefficients for Lung-RADS categorization and pooled intraclass correlation coefficients (ICCs) for nodule size measurements. Potential sources of heterogeneity were explored using metaregression analyses. EVIDENCE SYNTHESIS. The analysis included 11 studies (1470 patients) for Lung-RADS categorization and five studies (617 patients) for nodule size measurement. Interreader agreement for Lung-RADS categorization was substantial (κ = 0.72 [95% CI, 0.57-0.82]), and that for nodule size measurement was almost perfect (ICC = 0.97 [95% CI, 0.90-0.99]). Interreader agreement for Lung-RADS categorization was significantly associated with the method of nodule measurement (p = .005), with pooled kappa coefficients of 0.95, 0.91, and 0.66 for studies using computer-aided detection (CAD)-based semiautomated volume measurements, CAD-based semiautomated diameter measurements, and manual diameter measurements, respectively. Interreader agreement for Lung-RADS categorization was also significantly associated with studies' nodule type distribution (p < .001), with pooled kappa coefficients of 0.85, 0.76, and 0.55 for studies evaluating 100% solid nodules, 30-99% solid nodules, and fewer than 30% solid nodules, respectively. Interreader agreement for nodule size measurement was significantly associated with radiation dose (p < .001), with pooled ICCs of 0.97, 0.96, and 0.59 for studies that used standard-dose CT, low-dose CT, and ultralow-dose CT, respectively. Interreader agreement for nodule size measurement was also significantly associated with the Lung-RADS version that was used (p = .02), with pooled ICCs of 0.99 and 0.93 for studies using Lung-RADS 1.1 and Lung-RADS 1.0, respectively. CONCLUSION. Although they support the overall reliability of Lung-RADS, the findings indicate roles for CAD assistance as well as training and standardized approaches for nodule type characterization to further promote reproducible application. CLINICAL IMPACT. Consistent nodule assessments will be critical for Lung-RADS to optimally impact patient management and outcomes.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。

引用

  1. Hwang J, Kim PH, You S, et al. Interreader Agreement of Lung-RADS: A Systematic Review and Meta-Analysis. AJR Am J Roentgenol. 2025. PMID: 40202356. doi:10.2214/AJR.25.32681

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。