定量肺超声与婴儿成功拔管的关联
本前瞻性观察研究纳入接受有创通气的新生儿,用掌上超声仪行肺超声检查,按拔管成功与否及胎龄(<28周和≥28周)分组,采集拔管前半小时和拔管后2小时的肺超声征象与评分。拔管前后肺超声评分预测撤机失败的敏感度分别为83.3%和94.6%,特异度分别为83.3%和97.3%。结论认为肺超声评分可预测不同呼吸疾病新生儿的撤机失败,掌上便携超声仪行肺超声可行。
要点
- 拔管后2小时肺超声评分预测撤机失败的敏感度94.6%、特异度97.3%。
- 拔管前半小时肺超声评分预测撤机失败的敏感度83.3%、特异度83.3%。
- 胎龄<28周与≥28周组肺超声评分均可预测撤机失败。
核心结论
- 肺超声可基于肺超声评分预测不同呼吸疾病新生儿的撤机失败,无论胎龄是否存在差异。
- 使用掌上手持便携式超声仪行肺超声是可行的。
研究设计与样本
- 前瞻性观察研究,纳入接受有创通气的住院新生儿,排除因非呼吸系统疾病需机械通气等不符合入组条件的新生儿。
- 所有纳入新生儿均使用掌上超声仪行肺超声检查,拔管后分为成功组与失败组。
- 另按胎龄分为<28周组和≥28周组,采集拔管前半小时和拔管后2小时的肺超声主要征象与评分数据并比较超声评分。
诊断标准与关键数值
- 以拔管前肺超声评分预测撤机失败:敏感度83.3%,特异度83.3%(95% CI,0.823-0.986;P < .05)。
- 以拔管后肺超声评分预测撤机失败:敏感度94.6%,特异度97.3%(95% CI,0.819-0.995;P < .05)。
- 胎龄<28周组:拔管前后敏感度均为84.6%,特异度分别为77.8%和88.9%(拔管前95% CI,0.653-1.013;P < .001;拔管后95% CI,0.652-1.023;P < .001)。
- 胎龄≥28周组:拔管前后敏感度均为80.0%,特异度分别为96.9%和98.5%(拔管前95% CI,0.724-1.051;P < .001;拔管后95% CI,0.777-1.051;P < .001)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: The aim is to evaluate the value of lung ultrasound (LUS) in the weaning of neonates from ventilators.
METHODS: This prospective observational study included hospitalized neonates who underwent invasive ventilation (excluding neonates ineligible for enrollment, eg, neonates with nonrespiratory conditions requiring mechanical ventilation). All the included neonates underwent LUS using a palm-sized ultrasound machine. After extubation, the neonates were divided into success and failure groups. Additionally, the neonates were divided into 2 groups according to gestational age (GA, <28 weeks and ≥28 weeks). Data on the main LUS signs and scores half an hour before and 2 hours after extubation were collected, and ultrasound scores were compared.
RESULTS: When LUS scores before and after extubation were used to predict weaning failure, the sensitivities were 83.3 and 94.6% (95% CI, 0.823-0.986; P < .05), and the specificities were 83.3 and 97.3% (95% CI, 0.819-0.995; P < .05), respectively. After grouping, for the <28-week group, the sensitivity was 84.6% both before and after extubation, and the specificities were 77.8 and 88.9%, respectively (before extubation: 95% CI, 0.653-1.013; P < .001; after extubation: 95% CI, 0.652-1.023; P < .001). In the ≥28-week group, the sensitivity was 80.0% both before and after extubation, and the specificities were 96.9 and 98.5%, respectively (before extubation: 95% CI, 0.724-1.051; P < .001; after extubation: 95% CI, 0.777-1.051; P < .001).
CONCLUSIONS: LUS can predict weaning failure in neonates with different respiratory diseases on the basis of LUS scores, with or without differences in GA. The use of palm-sized handheld portable ultrasound machines for LUS is feasible.
引用
- Xie YM, Yan CM, Zhao X, et al. Associations Between Quantitative Lung Ultrasound and Successful Extubation in Infants. J Ultrasound Med. 2025. PMID: 40285664. doi:10.1002/jum.16715
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。