文献速递神经外周血管MR

利用生成对抗深度学习网络从乙酰唑胺给药前动脉自旋标记合成烟雾病脑血管反应性影像

Using generative adversarial deep learning networks to synthesize cerebrovascular reactivity imaging from pre-acetazolamide arterial spin labeling in moyamoya disease.
PubMed 文献 · Neuroradiology · 2025-04-04

本研究纳入203例烟雾病患者的3248幅乙酰唑胺给药前后动脉自旋标记脑血流量图像,以2640幅训练像素到像素生成对抗网络、608幅测试,由给药前图像合成脑血管反应性图;合成图与参考图的结构相似指数在测试集为0.943±0.020、空间相关系数为0.987±0.011,低反应区Dice相似系数为0.593±0.128,结论认为在乙酰唑胺激发不可行时合成脑血管反应性图可能是有用的替代方法。

要点

  • 合成脑血管反应性图与参考图结构相似指数达0.943±0.020,空间相关系数达0.987±0.011。
  • 低反应区自动分割的Dice相似系数为0.593±0.128,一致性中等。
  • 单层面判读一致性Cohen Kappa在测试集为0.813,半球层面为0.730。

核心结论

  • 作者认为,无需乙酰唑胺激发、由基线动脉自旋标记经生成对抗网络合成的脑血管反应性图,在乙酰唑胺激发不可行的临床应用中可能是有用的替代方法。

研究设计与样本

  • 本研究为方法学研究,纳入203例烟雾病病例,共3248幅乙酰唑胺给药前后动脉自旋标记脑血流量图像,并据此生成参考脑血管反应性图。
  • 其中2640幅用于训练由生成器和判别器组成的像素到像素生成对抗网络,其余608幅作为测试集。
  • 训练后将测试集的给药前脑血流量图输入训练好的模型以合成脑血管反应性图,并与参考图比较。

关键影像表现/征象

  • 原文未报告影像征象。

诊断标准与关键数值

  • 训练集与测试集合成脑血管反应性图的平均结构相似指数分别为0.943±0.019和0.943±0.020。
  • 训练集与测试集合成脑血管反应性图的平均空间相关系数分别为0.988±0.009和0.987±0.011。
  • 训练集与测试集合成脑血管反应性图的平均均方根误差分别为0.077±0.015和0.079±0.018。
  • 测试集低脑血管反应性区域的平均Dice相似系数为0.593±0.128。
  • 单层面判读脑血管反应性状态的Cohen Kappa在训练集为0.896、测试集为0.813,半球层面在训练集为0.781、测试集为0.730。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Cerebrovascular reactivity (CVR) assesses vascular health in various brain conditions, but CVR measurement requires a challenge to cerebral perfusion such as the administration of acetazolamide(ACZ), thus limiting widespread use. We determined whether generative adversarial networks (GANs) can create CVR images from baseline pre-ACZ arterial spin labeling (ASL) MRI.

METHODS: This study included 203 Moyamoya cases with a total of 3248 pre- and post-ACZ ASL Cerebral Blood Flow (CBF) images. Reference CVRs were generated from these CBF slices. From this set, 2640 slices were used to train a Pixel-to-Pixel GAN consisting of a generator and discriminator network, with the remaining 608 slices reserved as a testing set. Following training, the pre-ACZ CBF in the testing set was introduced to the trained model to generate synthesized CVR. The quality of the synthesized CVR was evaluated with structural similarity index(SSI), spatial correlation coefficient(SCC), and the root mean squared error(RMSE), compared with reference CVR. The segmentations of the low CVR regions were compared using the Dice similarity coefficient (DSC). Reference and synthesized CVRs in single-slice and individual-hemisphere settings were reviewed to assess CVR status, with Cohen's Kappa measuring consistency.

RESULTS: The mean SSIs of the CVR of training and testing sets were 0.943 ± 0.019 and 0.943 ± 0.020. The mean SCCs of the CVR of training and testing sets were 0.988 ± 0.009 and 0.987 ± 0.011. The mean RMSEs of the CVR are 0.077 ± 0.015 and 0.079 ± 0.018. Mean DSC of low CVR area of testing sets was 0.593 ± 0.128. Visual interpretation yielded Cohen's Kappa values of 0.896 and 0.813 for the training and testing sets in the single-slice setting, and 0.781 and 0.730 in the individual-hemisphere setting.

CONCLUSIONS: Synthesized CVR by GANs from baseline ASL without challenge may be a useful alternative in detecting vascular deficits in clinical applications when ACZ challenge is not feasible.

来源:Neuroradiology,查看原文。版权归原作者所有。

引用

  1. Zhu G, Jiang B, Chen H, et al. Using generative adversarial deep learning networks to synthesize cerebrovascular reactivity imaging from pre-acetazolamide arterial spin labeling in moyamoya disease. Neuroradiology. 2025. PMID: 40183965. doi:10.1007/s00234-025-03605-1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。