文献速递神经MR

正常压力脑积水基于MRI的脑脊液流动参考值系统综述与荟萃分析:揭示诊断不一致性

Systematic review and meta-analysis of MRI-based cerebrospinal fluid flow reference values in normal pressure hydrocephalus: unveiling diagnostic inconsistencies.
PubMed 文献 · Neuroradiology · 2025-04-23

该系统综述与荟萃分析遵循PRISMA指南,通过PubMed检索纳入报告特发性正常压力脑积水(iNPH)患者脑脊液流动参数(每搏输出量、收缩期峰值流速、舒张期峰值流速、平均流量)的定量研究,采用随机效应模型合并数据并以I²统计量评估异质性。结果显示每搏输出量与收缩期峰值流速在研究间存在显著变异,而平均流量在iNPH患者中较对照组持续升高(效应量0.143 ml/s;95%CI 0.131-0.155 ml/s),可能成为可靠的诊断标志物。

要点

  • 平均流量在iNPH患者中较对照组持续升高(效应量0.143 ml/s;95%CI 0.131-0.155 ml/s),可能作为可靠诊断标志物。
  • 每搏输出量与收缩期峰值流速在研究间存在显著变异,可能源于MRI方案、设备与患者人群差异。
  • 作者指出需标准化MRI协议以提高脑脊液流动测量的诊断准确性。

核心结论

  • 平均流量似乎是诊断iNPH最可靠的参数,因其在研究间具有一致性;每搏输出量与收缩期峰值流速的显著变异凸显了标准化MRI协议的必要性。

研究设计与样本

  • 系统综述与荟萃分析,遵循PRISMA指南,通过PubMed综合检索纳入报告iNPH患者定量脑脊液流动参数(每搏输出量、收缩期峰值流速、舒张期峰值流速、平均流量)的研究,采用随机效应模型合并数据,以I²统计量评估异质性。

诊断标准与关键数值

  • 平均流量在iNPH患者中较对照组持续升高,效应量0.143 ml/s(95%CI 0.131-0.155 ml/s)。
  • 每搏输出量与收缩期峰值流速在研究间存在显著变异,可能由MRI协议、设备与患者人群差异驱动。

临床应用与阅片要点

  • 作者认为平均流量似乎是诊断iNPH最可靠的参数,因其在研究间具有一致性。
  • 作者指出每搏输出量与收缩期峰值流速的显著变异凸显了标准化MRI协议以提高脑脊液流动测量诊断准确性的必要性。

局限性

  • 每搏输出量与收缩期峰值流速存在显著变异,可能由MRI协议、设备与患者人群差异驱动。
  • 作者指出未来研究应优先制定统一影像协议以减少异质性并提高iNPH诊断可靠性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: The primary aim of this meta-analysis is to assess the consistency and reliability of MRI-based cerebrospinal fluid (CSF) flow reference values in the diagnosis of Idiopathic Normal Pressure Hydrocephalus (iNPH). The research seeks to identify the sources of variability in CSF flow measurements and evaluate which parameters offer the most reliable diagnostic value.

METHODS: A systematic review and meta-analysis were conducted following PRISMA guidelines. Relevant studies were identified through a comprehensive search in PubMed. The inclusion criteria focused on studies reporting quantitative CSF flow parameters such as Stroke Volume (SV), Peak Systolic Velocity (PSV), Peak Diastolic Velocity (PDV), and Mean Flow (MF) in iNPH patients. Data were synthesized using a random-effects model, and heterogeneity was assessed using the I2 statistic.

RESULTS: The analysis revealed significant variability in SV and PSV across studies, likely driven by differences in MRI protocols, equipment, and patient populations. MF, however, consistently showed elevated values in iNPH patients compared to controls (effect size: 0.143 ml/s; 95% CI: 0.131-0.155 ml/s), suggesting its potential as a reliable diagnostic marker for iNPH.

CONCLUSION: MF appears to be the most reliable parameter for diagnosing iNPH, given its consistency across studies. However, the substantial variability in SV and PSV underscores the need for standardized MRI protocols to improve the diagnostic accuracy of CSF flow measurements. Future research should prioritize the development of unified imaging protocols to reduce heterogeneity and enhance diagnostic reliability in iNPH.

来源:Neuroradiology,查看原文。版权归原作者所有。

引用

  1. Navarro-Ballester A. Systematic review and meta-analysis of MRI-based cerebrospinal fluid flow reference values in normal pressure hydrocephalus: unveiling diagnostic inconsistencies. Neuroradiology. 2025. PMID: 40266315. doi:10.1007/s00234-025-03617-x

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。