大血管闭塞卒中患者多时相CTA侧支循环评估的阅片者间与阅片者内一致性研究

Assessment of collaterals on multiphase CTA in stroke patients with a large vessel occlusion: an interrater and intrarater agreement study.
PubMed 文献 · Neuroradiology · 2025-04-10

本研究由2名初级和2名高级评分者(分别来自卒中神经病学、诊断性神经放射学和介入神经放射学)对60例急性缺血性卒中患者的多时相CT血管成像进行侧支循环评估,采用以对侧半球为参照的3级评分(差:<50%侧支;中等:≥50%但<100%;好:100%),计算Fleiss kappa评估一致性。结果显示总体阅片者间一致性为中等,诊断性神经放射学医师间一致性更高;将评分二分为「差/中等 vs. 好」和「差 vs. 中等/好」可大幅提高各专科间一致性,后者更明显;阅片者内总体一致性为中等至基本一致,二分化后改善。结论提示该全局侧支评分经二分化后或可可靠用于临床实践。

要点

  • 多时相CTA全局侧支3级评分总体阅片者间一致性为中等,诊断性神经放射学医师间更高。
  • 二分为「差 vs. 中等/好」时各专科间一致性提升最明显,优于「差/中等 vs. 好」。
  • 阅片者内一致性为中等至基本一致,二分化后改善;作者认为二分化后或可可靠用于临床。

核心结论

  • 多时相CTA全局侧支3级评分的阅片者间与阅片者内一致性均为中等,将评分二分化后一致性改善,作者认为该评分经二分化后或可可靠用于临床实践。

研究设计与样本

  • 一致性研究,由2名初级和2名高级评分者(分别来自卒中神经病学、诊断性神经放射学和介入神经放射学)评估60例急性缺血性卒中患者的多时相CT血管成像,以对侧半球为参照,采用Fleiss kappa评估全局评分及多种二分法的一致性。

诊断标准与关键数值

  • 侧支循环3级评分标准:差为侧支<50%,中等为侧支≥50%但<100%,好为侧支100%,均以对侧半球为参照;总体阅片者间一致性为中等;二分为「差/中等 vs. 好」和「差 vs. 中等/好」后一致性大幅提高,后者更明显;阅片者内总体一致性为中等至基本一致,二分化后改善。

临床应用与阅片要点

  • 作者认为该全局侧支评分经二分化后或可可靠用于临床实践,尤其在「差 vs. 中等/好」二分法下各专科间一致性提升最明显。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: The assessment of collateral circulation is an important prognostic factor in patients with stroke due to large vessel occlusion. The results of a recent trial suggested that collateral status could even be used for thrombectomy decision making in patients with late window acute ischemic stroke. However, the reliability of collateral assessment is uncertain. We sought to assess the interrater and intrarater agreement of collateral assessment using multiphase CT angiography.

METHODS: Two junior and two senior raters in stroke neurology, diagnostic neuroradiology, and interventional neuroradiology evaluated 60 multiphase CT scans of acute ischemic stroke and scored the presence of collaterals as follows: poor (< 50% collaterals), moderate (≥ 50% but < 100% collaterals), and good (100% collaterals), using the contralateral hemisphere for reference. Agreement was assessed through Fleiss kappa scoring for the global scale and for various dichotomizations.

RESULTS: The overall interrater agreement for the assessment of collaterals on Multiphase CTA was moderate, with higher agreement found among diagnostic neuroradiologists. Dichotomizing the agreement scale into "poor/moderate vs. good" and "poor vs. moderate/good" greatly increased the interrater agreement among all specialties, especially in the latter scenario. Similarly, global intrarater agreement of CTA collateral images was determined to be moderate to substantial, with improvement after dichotomization.

CONCLUSION: Interrater and intrarater agreement for the global collateral scale was modest, with improvement after dichotomization. Our work suggests that this scale can be reliably used in clinical practice after dichotomization.

来源:Neuroradiology,查看原文。版权归原作者所有。

引用

  1. Ramamurthy J, Bebedjian R, Dowlatshahi D, et al. Assessment of collaterals on multiphase CTA in stroke patients with a large vessel occlusion: an interrater and intrarater agreement study. Neuroradiology. 2025. PMID: 40208268. doi:10.1007/s00234-025-03609-x

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。