文献速递心血管MR

修复后法洛四联症成人无对比剂4D与2D相位对比MRI血流评估的比较

Non-enhanced MRI flow evaluation using 4D versus 2D phase-contrast in repaired Tetralogy of Fallot adults.
PubMed 文献 · Eur Radiol · 2025-04-17

单中心回顾性研究纳入26例修复后法洛四联症成人,比较无对比剂4D-PC与2D-PC血流定量。4D扫描平均13分钟,非4D部分47分钟。4D对肺动脉反流分数和反流体积存在系统性低估(反流分数-10±15%,p=0.02;反流体积-13±18 mL,p=0.02),但肺动脉和主动脉反流分数一致性强度高(CCC分别为0.75和0.91)。结论认为无对比剂4D-PC血流MRI似乎是可靠的定量方法,但可能低估肺动脉反流。

要点

  • 4D-PC对肺动脉反流分数和反流体积存在系统性低估,报告时需注意。
  • 肺动脉反流分数一致性CCC=0.75,主动脉CCC=0.91,整体一致性强度高。
  • 4D扫描平均13分钟,非4D部分47分钟,可减少扫描时间。

核心结论

  • 无对比剂4D-PC血流MRI似乎是修复后法洛四联症患者可靠的定量血流方法,但可能低估肺动脉反流。

研究设计与样本

  • 单中心回顾性研究,2021至2023年纳入26例修复后法洛四联症成人,随访MRI方案包含无对比剂4D-PC和2D-PC,比较主动脉和肺动脉血流定量,采用Student t检验和Lin一致性相关系数(CCC),并设第二观察者。

诊断标准与关键数值

  • 肺动脉反流分数4D较2D系统性低估-10±15%(p=0.02)。
  • 肺动脉反流体积4D较2D系统性低估-13±18 mL(p=0.02)。
  • 肺动脉反流分数一致性CCC=0.75(95%CI 0.58-0.86,p<0.001)。
  • 主动脉反流分数一致性CCC=0.91(95%CI 0.81-0.95,p<0.001)。
  • 观察者间一致性整体强度高。

临床应用与阅片要点

  • 4D-PC扫描平均时间13分钟,非4D部分47分钟。
  • 4D-PC无需对比剂,可减少脑部钆暴露并缩短扫描时间。
  • 作者认为4D-MR是准确且多用途的心脏检查工具,可能改善患者舒适度。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To describe the reliability of quantitative MRI analysis of flows using 4D-PC (Phase Contrast) compared to 2D-PC flow, without contrast agents.

MATERIALS AND METHODS: The study was conducted at one centre in a retrospective manner from 2021 to 2023. Eligible patients were adults with repaired Tetralogy of Fallot (rToF) whose follow-up MRI protocol included 4D-PC and 2D-PC, without contrast agent. Assessment involved quantitative measurement of aortic and pulmonary flows on both 4D and 2D. Student's T was used for comparisons of means and Lin's concordance correlation coefficient agreement (CCC). A 2nd observer was hired.

RESULTS: Twenty-six patients were included (50% men, median age of 27 [20; 34]). Scanning mean time was 13 min for 4D and 47 min for non-4D part. Systematic underestimation in pulmonary regurgitation fraction (-10 ± 15%, p = 0.02) and backward volume (-13 ± 18 mL, p = 0.02) was found. Agreement on regurgitant fraction was strong for pulmonary (CCC = 0.75 [0.58-0.86], p < 0.001) and aortic (CCC = 0.91 [0.81-0.95], p < 0.001). Inter-observer showed overall strong results.

CONCLUSION: Non-enhanced 4D-PC flow MRI seems to be a reliable method of quantitative flow in rToF patients, but it may underestimate pulmonary regurgitation.

KEY POINTS: Question 4D-MRI stands out as an innovative tool for evaluating flows in adults with repaired Tetralogy of Fallot during follow-up. Findings 4D phase-contrast imaging without the use of contrast agents exhibits robust results and high reproducibility. Clinical relevance 4D-MR is presented as an accurate and versatile tool of cardiac exploration that could improve patient comfort. Minimizing brain gadolinium exposure and reducing scanning time are key objectives of non-enhanced 4D-MR.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Champollion JAF, Senage T, Marteau L, et al. Non-enhanced MRI flow evaluation using 4D versus 2D phase-contrast in repaired Tetralogy of Fallot adults. Eur Radiol. 2025. PMID: 40244407. doi:10.1007/s00330-025-11542-z

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。