基于深度学习利用动态对比增强MRI数据生成DSC MRI参数图
该研究独立分析既往收集的64例含脑肿瘤与非肿瘤参与者的数据,设计条件生成对抗网络(cGAN)从DCE MRI数据合成DSC衍生参数图。合成参数图与真实DSC图的中位参数值和分布相似,肿瘤区域合成参数与真实值呈线性相关,且DCE衍生图可显示真实DSC图中磁敏感伪影遮挡的区域,提示单剂量对比剂即可获得两类参数图的潜力。
要点
- cGAN合成的DSC参数图在无脑肿瘤对照者中分布与真实值相似,在肿瘤区域与真实值线性相关。
- DCE衍生DSC图可显示真实DSC图中因磁敏感伪影不可见的区域。
- 研究提示单剂量对比剂下从DCE MRI同时获得DSC与DCE参数图的潜力。
核心结论
- DSC衍生参数图可由DCE MRI数据合成,包括易受磁敏感伪影影响的区域,提示单剂量对比剂即可获得DSC与DCE两类参数图的潜力。
研究设计与样本
- 对既往研究收集数据行独立分析,数据库含64例有或无脑肿瘤的参与者,参考参数图来自DCE MRI后进行的DSC MRI,设计并训练条件生成对抗网络(cGAN)从DCE MRI数据生成合成DSC衍生图。
关键影像表现/征象
- 无脑肿瘤对照者中,合成参数的分布与真实值相似。
- 脑肿瘤患者肿瘤区域,合成参数与真实值呈线性相关。
- 真实DSC图中因磁敏感伪影不可见的区域,在DCE衍生DSC图中可显示。
诊断标准与关键数值
- 合成图与真实图的中位参数值和分布采用线性回归与Bland-Altman图比较。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND AND PURPOSE: Perfusion and perfusion-related parameter maps obtained by using DSC MRI and dynamic contrast-enhanced (DCE) MRI are both useful for clinical diagnosis and research. However, using both DSC and DCE MRI in the same scan session requires 2 doses of gadolinium contrast agent. The objective was to develop deep learning-based methods to synthesize DSC-derived parameter maps from DCE MRI data.
MATERIALS AND METHODS: Independent analysis of data collected in previous studies was performed. The database contained 64 participants, including patients with and without brain tumors. The reference parameter maps were measured from DSC MRI performed after DCE MRI. A conditional generative adversarial network (cGAN) was designed and trained to generate synthetic DSC-derived maps from DCE MRI data. The median parameter values and distributions between synthetic and real maps were compared by using linear regression and Bland-Altman plots.
RESULTS: Using cGAN, realistic DSC parameter maps could be synthesized from DCE MRI data. For controls without brain tumors, the synthesized parameters had distributions similar to the ground truth values. For patients with brain tumors, the synthesized parameters in the tumor region correlated linearly with the ground truth values. In addition, areas not visible due to susceptibility artifacts in real DSC maps could be visualized by using DCE-derived DSC maps.
CONCLUSIONS: DSC-derived parameter maps could be synthesized by using DCE MRI data, including susceptibility-artifact-prone regions. This shows the potential to obtain both DSC and DCE parameter maps from DCE MRI by using a single dose of contrast agent.
引用
- Pei H, Lyu Y, Lambrecht S, et al. Deep Learning-Based Generation of DSC MRI Parameter Maps Using Dynamic Contrast-Enhanced MRI Data. AJNR Am J Neuroradiol. 2025. PMID: 40194853. doi:10.3174/ajnr.A8768
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。