文献速递神经儿科影像MR

评估一种用于视网膜出血的新型MR成像生物标志物

Evaluating a novel MR imaging biomarker for retinal hemorrhage.
PubMed 文献 · Pediatr Radiol · 2025-04-22

这项回顾性单中心研究纳入70例经眼科医师确认的视网膜出血患儿和74例良性大头畸形患儿,由两名儿科神经放射科医师盲法评估轴位脂肪抑制T2加权快速自旋回波MR图像上眶脂肪内高信号环。 adjudication后,视网膜出血组67/70例(96%)至少一眼可见高信号环,良性大头畸形组3/74例(4%)可见(P < 0.0001);作者认为高信号环可能有助于虐待性头部外伤后视网膜出血的检测。

要点

  • 眶脂肪内高信号环在经眼科确认的视网膜出血患儿中出现频率高(67/70,96%)。
  • 良性大头畸形对照组仅3/74(4%)可见高信号环,组间差异有统计学意义(P < 0.0001)。
  • 高信号环不是MR成像伪影,也不是婴幼儿的正常发育表现。

核心结论

  • 眶脂肪内高信号环在经眼科确认的视网膜出血患儿中出现频率高,且不是MR成像伪影或婴幼儿正常发育表现,可能有助于虐待性头部外伤后视网膜出血的检测。

研究设计与样本

  • 回顾性单中心研究,纳入2011年7月至2019年12月年龄>6周至<3岁、经眼科医师确认的视网膜出血病例70例,以及同期年龄>6周至<3岁良性大头畸形参考患者74例,均行完整脑部MR成像;由两名对分组不知情的儿科神经放射科医师阅片,随机抽取部分图像重复判读。

关键影像表现/征象

  • 轴位脂肪抑制T2加权快速自旋回波MR图像上,眶脂肪内可见高信号环。
  • adjudication后,视网膜出血组67/70例(96%)至少一眼可见高信号环。
  • 良性大头畸形组3/74例(4%)可见高信号环(P < 0.0001)。
  • 按影像上可见视网膜出血分层及按磁场强度分层后,结果相似。

诊断标准与关键数值

  • 以眼科医师确认的视网膜出血为参考标准,高信号环在视网膜出血患儿中的出现频率为67/70(96%),在良性大头畸形对照组为3/74(4%)(P < 0.0001)。
  • 阅片者内信度和阅片者间信度均高(所有κ ≥ 0.86),重复判读的一致率≥93%。

临床应用与阅片要点

  • 在儿童脑部MR轴位脂肪抑制T2加权快速自旋回波图像上,可观察眶脂肪内高信号环这一征象。
  • 作者认为高信号环可能有助于虐待性头部外伤后视网膜出血的检测。

局限性

  • 本研究为回顾性单中心研究。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Dilated fundus examination is the clinical reference standard for retinal hemorrhage diagnosis. Obtaining a timely examination may be challenging in emergent and inpatient settings, and retinal hemorrhage may go undetected. An imaging biomarker is therefore desirable.

OBJECTIVE: To evaluate the frequency of ringlets of hyperintensity in orbital fat on axial fat-suppressed T2-weighted fast spin echo MR images in children with ophthalmologically-confirmed retinal hemorrhage and in a comparison group of children with benign macrocrania.

MATERIALS AND METHODS: This retrospective single-center study included cases aged > 6 weeks- < 3 years with ophthalmologist-confirmed retinal hemorrhage from 07/2011-12/2019 who underwent full brain MR imaging and reference patients aged > 6 weeks- < 3 years with benign macrocrania who underwent brain MR imaging during the same period. Images were reviewed by two pediatric neuroradiologists blinded to patient group; a subset was randomly selected for duplicate reads. Descriptive data were tabulated for each reviewer and adjudicated results.

RESULTS: After adjudication, ringlets were observed in at least one eye in 67/70 retinal hemorrhage cases (96%) and 3/74 benign macrocrania patients (4%; P < 0.0001). Similar results were observed upon stratification by presence of visible retinal hemorrhage on imaging, and by magnet strength. Intrarater reliability and interrater reliability were high (all κ ≥ 0.86), with concordance rates ≥ 93% across duplicate reads.

CONCLUSION: Ringlets of hyperintensity are present at high frequency in children with confirmed retinal hemorrhage and are neither an MR imaging artifact, nor a normal developmental finding in infants and young children. As such, they may aid in retinal hemorrhage detection following abusive head trauma.

来源:Pediatr Radiol,查看原文。版权归原作者所有。

引用

  1. Linabery AM, Halvorson KG, Patel SR, et al. Evaluating a novel MR imaging biomarker for retinal hemorrhage. Pediatr Radiol. 2025. PMID: 40261342. doi:10.1007/s00247-025-06236-z

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。