多发性硬化患者中应用生成对抗网络从64毫特斯拉低场强MRI合成多序列3特斯拉图像
本研究纳入两个机构的多发性硬化成人患者,采用配对的64毫特斯拉与3特斯拉MRI数据,开发生成对抗网络架构LowGAN,将低场强图像转换为高场强质量图像。与低场强输入图像相比,LowGAN合成的高场强图像视觉质量更高,T1加权和FLAIR的结构相似性指数更高,皮层体积与3特斯拉测量无显著差异,白质病灶分割Dice评分提高。
要点
- LowGAN可将64毫特斯拉低场强脑MRI合成为高场强质量图像,T1加权结构相似性指数0.87 vs 0.82(P < .001)。
- FLAIR结构相似性指数0.88 vs 0.85(P < .001),合成图像视觉质量更高。
- 白质病灶分割Dice评分0.32 vs 0.28(P < .001),LowGAN优于原始64毫特斯拉图像。
核心结论
- 将LowGAN超分辨率应用于超低场强MRI,与标准超低场强图像相比提高了图像质量。
研究设计与样本
- 观察性研究,开发并评估生成对抗网络架构LowGAN,使用两个机构多发性硬化成人患者的配对64毫特斯拉与3特斯拉MRI数据,主要组50例(中位年龄47岁,IQR 38-56岁;38例女性),验证组13例(中位年龄41岁,IQR 35-53岁;11例女性),采集T1加权、T2加权和FLAIR序列。
关键影像表现/征象
- 与低场强输入图像相比,LowGAN合成的高场强图像视觉质量更高。
- T1加权结构相似性指数0.87 vs 0.82(P < .001),FLAIR结构相似性指数0.88 vs 0.85(P < .001)。
- LowGAN输出的皮层体积与3特斯拉测量无显著差异(483.6 cm3 vs 482.1 cm3;P = .99)。
诊断标准与关键数值
- 图像质量以结构相似性指数评估,T1加权LowGAN合成图像0.87 vs 低场强输入0.82(P < .001),FLAIR 0.88 vs 0.85(P < .001)。
- 白质病灶分割以Dice评分评估,LowGAN 0.32 vs 原始64毫特斯拉图像0.28(P < .001)。
- 皮层体积LowGAN输出483.6 cm3 vs 3特斯拉测量482.1 cm3(P = .99)。
临床应用与阅片要点
- LowGAN超分辨率可提高超低场强MRI图像质量,合成图像在结构相似性和病灶分割方面优于原始低场强图像。
- 皮层体积测量与3特斯拉无显著差异,白质病灶分割Dice评分仍较低(0.32 vs 0.28)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Background Portable low-field-strength (64-mT) MRI scanners show promise for increasing access to neuroimaging for clinical and research purposes; however, these devices produce lower-quality images than conventional high-field-strength scanners. Purpose To develop and evaluate a deep learning architecture to generate high-field-strength quality brain images from low-field-strength inputs using paired data from patients with multiple sclerosis (MS) who underwent MRI at 64 mT and 3 T. Materials and Methods Adults with MS at two institutions were scanned using portable 64-mT and standard 3-T scanners, with T1-weighted, T2-weighted, and fluid-attenuated inversion recovery (FLAIR) acquisitions as part of an observational study (October 2020 to January 2022); a second validation group (January 2023 to January 2024) was also included. Using paired data, a generative adversarial network architecture for low- to high-field-strength image translation, called LowGAN, was developed. Synthetic images were evaluated with respect to image quality (eg, structural similarity index), brain morphometry, and white matter lesions. Nonparametric Wilcoxon tests were used for comparison of image quality and morphometry, and Dice scores were used for comparison of lesion segmentations. Results A total of 50 participants (median age, 47 years [IQR, 38-56 years]; 38 female) were included in the main group, and 13 participants were included in the validation group (median age, 41 years [IQR 35-53 years]; 11 female). Compared with low-field-strength input images, LowGAN synthetic high-field-strength images were visually higher in quality and showed higher structural similarity index relative to actual high-field-strength images for T1-weighted (0.87 vs 0.82; P < .001) and FLAIR (0.88 vs 0.85; P < .001) contrasts. Cerebral cortex volumes in LowGAN outputs did not differ significantly from 3-T measurements (483.6 cm3 vs 482.1 cm3; P = .99). For white matter lesions, LowGAN increased lesion segmentation Dice scores relative to 3-T imaging when compared with native 64-mT images (0.32 vs 0.28; P < .001). Conclusion Application of LowGAN super-resolution to ultralow-field-strength MRI improved image quality compared with standard-of-care ultralow-field-strength images. © RSNA, 2025 Supplemental material is available for this article. See also the editorial by Wang and Zaharchuk in this issue.
引用
- Lucas A, Arnold TC, Okar SV, et al. Multisequence 3-T Image Synthesis from 64-mT Low-Field-Strength MRI Using Generative Adversarial Networks in Multiple Sclerosis. Radiology. 2025. PMID: 40261176. doi:10.1148/radiol.233529