文献速递神经外周血管CT

非狭窄性颈动脉斑块影像评估在不明来源栓塞性卒中中的应用

Imaging of non-stenotic carotid plaque for embolic stroke of undetermined source.
PubMed 文献 · Eur J Radiol · 2025-04-05

回顾性纳入2020年6月至2022年6月81例单侧前循环不明来源栓塞性卒中(ESUS)患者,用CTA评估双侧颈动脉非狭窄性斑块(NSCP)的患病率及斑块特征。结果示同侧颈动脉NSCP发生率显著高于对侧(76.5% vs 60.5%,P=0.028),斑块内低密度区(aOR=6.449,95%CI 1.818-22.878)和较大斑块厚度(aOR=2.476,95%CI 1.14-5.38)与ESUS显著相关。

要点

  • 单侧前循环ESUS患者同侧颈动脉NSCP发生率显著高于对侧(76.5% vs 60.5%)。
  • 斑块内低密度区与ESUS显著相关(aOR=6.449,95%CI 1.818-22.878)。
  • 较大斑块厚度与ESUS显著相关(aOR=2.476,95%CI 1.14-5.38)。

核心结论

  • ESUS患者卒中同侧NSCP患病率更高且斑块特征更复杂,较大斑块厚度和斑块内低密度区与ESUS显著相关,这些斑块可能是ESUS的重要栓塞来源。

研究设计与样本

  • 回顾性研究,纳入2020年6月至2022年6月81例单侧前循环ESUS患者,采用CTA评估双侧颈动脉,以单侧前循环ESUS为参照分析NSCP及斑块特征与同侧卒中的关系。

关键影像表现/征象

  • 同侧颈动脉NSCP发生率76.5%,对侧60.5%,同侧显著高于对侧(P=0.028)。
  • 斑块类型、斑块厚度、斑块厚度>3 mm及斑块内局灶性低密度区在两侧颈动脉斑块间差异均有统计学意义(均P<0.05)。

诊断标准与关键数值

  • 多因素logistic回归显示斑块内低密度区与ESUS显著相关(aOR=6.449,95%CI 1.818-22.878)。
  • 多因素logistic回归显示较大斑块厚度与ESUS显著相关(aOR=2.476,95%CI 1.14-5.38)。

临床应用与阅片要点

  • 对单侧前循环ESUS患者行CTA评估时,除狭窄程度外应关注同侧颈动脉NSCP的存在。
  • 阅片时注意评估斑块厚度(尤其>3 mm)、斑块类型、斑块不规则、溃疡及斑块内低密度区等特征。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Ischemic stroke is a significant cause of death and disability. Embolic Stroke of Undetermined Source (ESUS) accounts for a large proportion of acute ischemic strokes. A clear etiology is crucial for the treatment and prevention of stroke. The pathogenic mechanism of non-stenotic carotid plaque (NSCP) in ESUS is not yet fully understood. This study used computed tomographic angiography (CTA) to assess the correlation between NSCP and ESUS.

METHOD: Eighty-one patients with unilateral anterior circulation ESUS were retrospectively enrolled between June 2020 and June 2022. The prevalence of NSCP, degree of stenosis, plaque thickness, plaque type, plaque irregularity, plaque ulceration, focal areas of hypodensity within the plaque, and positive remodeling were evaluated in both carotid arteries on CTA. Univariate and multivariate logistic regression were used to determine the relationship between NSCP, plaque characteristics, and ipsilateral stroke.

RESULTS: Among 81 patients with unilateral anterior circulation ESUS, the incidence of NCSP was significantly higher in the ipsilateral carotid artery than in the contralateral side (76.5 % vs. 60.5 %, P = 0.028). Plaque type, plaque thickness, plaque thickness >3 mm, and focal areas of hypodensity within the plaque were remarkably different between two sides of carotid plaques (all P < 0.05). In addition, multifactorial logistic regression showed that intraplaque hypodensity (aOR = 6.449 [95 % CI, 1.818-22.878]) and greater plaque thickness (aOR = 2.476 [95 % CI, 1.14-5.38]) were significantly associated with ESUS.

CONCLUSIONS: The prevalence of NSCP ipsilateral to stroke is higher in ESUS patients, and more complex plaque features were found on the ipsilateral side. Greater plaque thickness and hypodensity within the plaque were significantly associated with ESUS, and these plaques may be an important embolization source of ESUS.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Li T, Liu H, Wang L, et al. Imaging of non-stenotic carotid plaque for embolic stroke of undetermined source. Eur J Radiol. 2025. PMID: 40209482. doi:10.1016/j.ejrad.2025.112097

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。