指南与共识腹部技术与安全US

SIAD与AFEF关于超声弹性成像临床实践实施的最佳实践立场文件

SIAD (Societé d'Imagerie Abdominale et Digestive) and AFEF (Association Française pour l'Etude du Foie) best practice position paper on the implementation of ultrasound elastography in clinical practice.
指南 / 共识 · Diagn Interv Imaging · 2025-04-09

该立场文件由法国腹部与消化影像学会(SIAD)和法国肝病研究协会(AFEF)组织放射学与肝病学专家,采用在线Delphi方法制定共识,共识阈值≥80%参与者同意。文件针对测量推荐、影响结果与可靠性的因素以及超声弹性成像结果标准化报告提出推荐,旨在提高评估可靠性。

要点

  • 超声弹性成像结果准确性与可靠性可受操作者相关和患者相关多种因素显著影响。
  • 共识推荐涵盖测量方法及影响结果与可靠性的因素。
  • 共识推荐涵盖超声弹性成像结果的标准化报告。

核心结论

  • 该立场文件为临床医生提供全面且易于获取的指南,概述最佳实践和标准化方案以提高超声弹性成像评估的可靠性。

研究设计与样本

  • 法国放射学与肝病学国家共识专家组,由SIAD和AFEF召集,采用在线Delphi方法(包括在线小组讨论和条目准备)制定立场声明,≥80%参与者同意即达成共识。

诊断标准与关键数值

  • 共识达成标准为≥80%的参与者同意特定推荐。
  • 推荐领域包括测量推荐及影响结果与可靠性的因素。
  • 推荐领域包括超声弹性成像结果的标准化报告指南。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: The diagnosis of liver fibrosis is critical in managing chronic liver diseases. The EASL guidelines now recognize ultrasound elastography as a valuable, non-invasive method for assessing liver fibrosis. However, there is a lack of uniform use and reporting of the technique. The purpose of this position paper was to provide guidance on using ultrasound elastography techniques and interpreting results in clinical practice.

MATERIALS AND METHODS: A French national consensus panel of experts in radiology and hepatology, convened by SIAD (Société d'Imagerie Abdominale et Digestive) and AFEF (Association Française pour l'Etude du Foie), developed a position statement paper on best practices in ultrasound elastography. They were established using an online Delphi methodology that included an online panel discussion and item preparation. Consensus was achieved when ≥ 80 % of the participants agreed with a specific recommendation.

RESULTS: The accuracy and reliability of ultrasound elastography results could be significantly affected by a variety of operator-related and patient-related factors. Standard recommendations have been established in two areas, including recommendations for measurements and factors affecting results and reliability, and guidelines for standardized reporting of ultrasound elastography results.

CONCLUSION: This position paper is a comprehensive and accessible guide for clinicians that outlines best practices and standardized protocols to improve the reliability of ultrasound elastography assessments.

来源:Diagn Interv Imaging,查看原文。版权归原作者所有。

引用

  1. Parlati L, Aubé C, Lewin M, et al. SIAD (Societé d'Imagerie Abdominale et Digestive) and AFEF (Association Française pour l'Etude du Foie) best practice position paper on the implementation of ultrasound elastography in clinical practice. Diagn Interv Imaging. 2025. PMID: 40210513. doi:10.1016/j.diii.2025.03.010

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。