文献速递骨肌MR

腓骨肌腱病变患者术中表现与MRI观察的关联:一项盲法回顾性病例对照观察研究

Association of intra-operative findings with MRI observations in patients with peroneal tendon pathology: a blinded retrospective case-control observational study.
PubMed 文献 · Skeletal Radiol · 2025-03-22

本研究将因腓骨肌腱撕裂行手术清创患者的术前MRI与匹配的内踝疼痛对照组MRI配对,由三名肌骨放射科医师盲法随机阅片,评估MRI对腓骨肌腱撕裂的准确性及观察者间/内信度。结果显示MRI对腓骨短肌腱撕裂诊断价值较高(共识敏感度84%、特异度92%、准确率88%),但对腓骨长肌腱撕裂敏感度较低(共识36%);上腓骨支持带撕裂在病例组占55.9%、对照组无一例,诊断效能最强。

要点

  • MRI对腓骨短肌腱撕裂诊断准确率较高,共识敏感度84%、特异度92%、准确率88%。
  • MRI对腓骨长肌腱撕裂敏感度低,共识仅36%,特异度91%、准确率79%。
  • 上腓骨支持带撕裂见于55.9%病例、对照组0例,为最具诊断价值的次要征象。

核心结论

  • MRI是评估腓骨短肌腱撕裂的有价值工具,但对腓骨长肌腱撕裂的检测敏感度可能较低。
  • 不同放射科医师间诊断准确率相似,但敏感度/特异度存在差异。
  • 无单个放射科医师的准确率高于共识诊断,作者认为诊断不确定时多学科会诊可能有价值。

研究设计与样本

  • 盲法回顾性病例对照观察研究,将因腓骨肌腱撕裂行手术清创患者的术前MRI与匹配的内踝疼痛对照组MRI配对。
  • 随机顺序的MRI由三名肌骨放射科医师独立阅片,记录腓骨肌腱结构异常及伴随形态学异常。
  • 以手术诊断为参考标准,分析共识MRI表现与手术诊断的关联。
  • 采用加权Cohen's kappa和Fleiss' kappa系数描述观察者间及观察者内一致性。

关键影像表现/征象

  • 上腓骨支持带撕裂在病例组中占55.9%,对照组中无一例出现。
  • 原文报告多种次要MR表现与腓骨肌腱撕裂存在关联。

诊断标准与关键数值

  • 腓骨短肌腱撕裂:单个读者敏感度58%–87%、特异度78%–97%、准确率79%–87%;共识敏感度84%、特异度92%、准确率88%。
  • 腓骨长肌腱撕裂:单个读者敏感度14%–57%、特异度76%–94%、准确率72%–79%;共识敏感度36%、特异度91%、准确率79%。
  • 上腓骨支持带撕裂在病例组出现率55.9%,对照组0%,为最具诊断效能的MRI表现。

临床应用与阅片要点

  • 阅片时应系统评估腓骨短肌腱和腓骨长肌腱,注意后者撕裂的MRI敏感度较低。
  • 上腓骨支持带撕裂对鉴别腓骨肌腱病变具有较高提示价值,病例组出现率55.9%而对照组无一例。
  • 作者认为诊断不确定时,多放射科医师会诊可能有助于提高诊断准确性。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: Assess the accuracy of MRI for peroneal tendon tears, evaluate inter/intra-rater reliability among musculoskeletal radiologists, and identify MRI findings that may be associated with tendon tears.

MATERIALS AND METHODS: Preoperative MRIs of patients who underwent surgical debridement of peroneal tendon tears were paired with MRIs of a matched control group with medial ankle pain. Randomized MRIs were reviewed by three musculoskeletal radiologists, recording the presence of structural abnormalities of the peroneal tendons and associated morphological abnormalities. Consensus MRI findings were analyzed for associations with surgical diagnoses. Weighted Cohen's and Fleiss' kappa coefficients were used to describe inter/intra-rater agreement.

RESULTS: For peroneus brevis tear, individual sensitivities ranged from 58 to 87%, specificities ranged from 78 to 97%, and accuracies ranged from 79 to 87%, while consensus showed 84% sensitivity, 92% specificity, and 88% accuracy. For peroneus longus tear, individual sensitivities ranged from 14 to 57%, specificities ranged from 76 to 94%, and accuracies ranged from 72 to 79%, while consensus showed 36% sensitivity, 91% specificity, and 79% accuracy. Associations were detected between peroneal tendon tears and numerous secondary MR findings. Tearing of the superior peroneal retinaculum was most diagnostically powerful, present in 55.9% of cases and in none of the controls.

CONCLUSION: MRI is a valuable tool for assessing for peroneus brevis tears but may be less sensitive for detecting peroneus longus tears. Diagnostic accuracy is similar between radiologists, but there is variability in sensitivity/specificity. No individual radiologist achieved a higher accuracy than that obtained through consensus. This may imply value in additional opinions from multiple radiologists when there is diagnostic uncertainty.

来源:Skeletal Radiol,查看原文。版权归原作者所有。

引用

  1. Stewart ZE, Ghandour S, Mercer RW, et al. Association of intra-operative findings with MRI observations in patients with peroneal tendon pathology: a blinded retrospective case-control observational study. Skeletal Radiol. 2025. PMID: 40119883. doi:10.1007/s00256-025-04915-4

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。