去噪扩散概率模型模拟脊柱肿瘤增强脊柱MRI:一项多中心研究
研究纳入两家医院1195例连续脊柱肿瘤患者的增强MRI,用去噪扩散概率模型(DDPM)从平扫脊柱MRI序列生成虚拟T1增强序列,并与基线模型pix2pix及三种先进模型比较。外部测试集中生成图像总体敏感度94%、错误发现率2%,病灶大小与信号强度比与参考图像无差异,生成图像CNR高于参考图像(9.241 vs. 4.021,P<0.001)。
要点
- DDPM可从平扫T1、T2及T2脂肪抑制序列生成虚拟T1增强图像。
- 外部测试集中生成图像总体敏感度94%、错误发现率2%。
- 生成图像病灶大小及信号强度比与参考图像无差异。
核心结论
- 所提出的DDPM在肿瘤患者脊柱MRI检查中显示出作为钆对比剂替代方案的潜力。
研究设计与样本
- 多中心研究,共纳入1195例连续脊柱肿瘤患者,训练集809例(49±17岁,男437例)、内部测试集203例(50±16岁,男105例)、外部测试集183例(52±16岁,男94例);输入为T1加权、T2加权及T2脂肪抑制图像,输出为T1CE图像。
诊断标准与关键数值
- 外部测试集均方误差0.0038±0.0065,结构相似性指数0.78±0.10。
- 由一名放射科医师阅读生成图像,总体敏感度94%、错误发现率2%。
- 参考图像与生成图像之间病灶大小及信号强度比无差异。
- 生成图像CNR高于参考图像(9.241 vs. 4.021,P<0.001)。
临床应用与阅片要点
- 生成虚拟T1CE图像可用于标记所有可见强化病灶。
- 作者认为DDPM在肿瘤患者脊柱MRI检查中可能作为钆对比剂的替代方案。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: To generate virtual T1 contrast-enhanced (T1CE) sequences from plain spinal MRI sequences using the denoising diffusion probabilistic model (DDPM) and to compare its performance against one baseline model pix2pix and three advanced models.
METHODS: A total of 1195 consecutive spinal tumor patients who underwent contrast-enhanced MRI at two hospitals were divided into a training set (n = 809, 49 ± 17 years, 437 men), an internal test set (n = 203, 50 ± 16 years, 105 men), and an external test set (n = 183, 52 ± 16 years, 94 men). Input sequences were T1- and T2-weighted images, and T2 fat-saturation images. The output was T1CE images. In the test set, one radiologist read the virtual images and marked all visible enhancing lesions. Results were evaluated using sensitivity (SE) and false discovery rate (FDR). We compared differences in lesion size and enhancement degree between reference and virtual images, and calculated signal-to-noise (SNR) and contrast-to-noise ratios (CNR) for image quality assessment.
RESULTS: In the external test set, the mean squared error was 0.0038±0.0065, and structural similarity index 0.78±0.10. Upon evaluation by the reader, the overall SE of the generated T1CE images was 94% with FDR 2%. There was no difference in lesion size or signal intensity ratio between the reference and generated images. The CNR was higher in the generated images than the reference images (9.241 vs. 4.021; P<0.001).
CONCLUSION: The proposed DDPM demonstrates potential as an alternative to gadolinium contrast in spinal MRI examinations of oncologic patients.
引用
- Wang C, Zhang S, Xu J, et al. Denoising Diffusion Probabilistic Model to Simulate Contrast-enhanced spinal MRI of Spinal Tumors: A Multi-Center Study. Acad Radiol. 2025. PMID: 40023741. doi:10.1016/j.acra.2025.02.024
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。