文献速递骨肌MRUS

MRI与超声诊断腓骨肌腱撕裂的诊断准确性:系统评价与Meta分析

Diagnostic accuracy of MRI and US for peroneal tendon tears: a systematic review and meta-analysis.
PubMed 文献 · Eur Radiol · 2025-03-04

该系统评价与Meta分析纳入12项研究,评估MRI和超声诊断腓骨短肌腱和长肌腱撕裂的准确性。汇总数据显示,超声对腓骨短肌腱撕裂的敏感度高于MRI(93% vs 73%),两者特异度相近;对腓骨长肌腱,超声敏感度和特异度均高(94%和94%),MRI特异度高(91%)但敏感度低(60%)。所有研究均存在高偏倚风险,结果异质性大,无法得出某一模态优劣的肯定结论。

要点

  • 超声对腓骨短肌腱撕裂的汇总敏感度93%,高于MRI的73%,两者特异度相近(85% vs 88%)。
  • 超声对腓骨长肌腱撕裂的汇总敏感度94%、特异度94%,MRI敏感度仅60%、特异度91%。
  • 纳入研究均存在高偏倚风险,结果异质性大,尚不能肯定任一模态的优劣。

核心结论

  • 超声对腓骨肌腱撕裂表现为敏感且特异,MRI表现为特异但不敏感;但文献稀缺且结果异质性大,无法得出任一模态优劣的肯定结论。

研究设计与样本

  • 系统评价与Meta分析,检索Scopus、EMBASE和PubMed,纳入12项研究(8项仅MRI、3项仅超声、1项两者均含),采用QUADAS-2工具进行系统评价,使用双变量随机效应模型计算汇总诊断准确性。

诊断标准与关键数值

  • 腓骨短肌腱撕裂:超声汇总敏感度93%(95%CI:75%,98%),MRI汇总敏感度73%(95%CI:56%,87%);超声汇总特异度85%(95%CI:55%,96%),MRI汇总特异度88%(95%CI:70%,95%)。
  • 腓骨长肌腱撕裂:超声汇总敏感度94%(95%CI:71%,99%),汇总特异度94%(95%CI:79%,98%);MRI汇总敏感度60%(95%CI:35%,85%),汇总特异度91%(95%CI:76%,97%)。

临床应用与阅片要点

  • 对于腓骨短肌腱撕裂,超声汇总敏感度高于MRI(超声93% vs MRI 73%),两者特异度相近(超声85% vs MRI 88%)。
  • 对于腓骨长肌腱撕裂,超声汇总敏感度和特异度均高(94%和94%),MRI特异度91%但敏感度60%。
  • 所有纳入研究均存在高偏倚风险,仅1项研究满足4项偏倚风险标准中至少2项,结果异质性大,解释汇总数据时需谨慎。

局限性

  • 所有纳入研究均存在高偏倚风险,仅1项研究满足4项偏倚风险标准中至少2项。
  • MRI和超声的报告准确性数据均存在异质性。
  • 文献稀缺且结果异质性大,无法得出任一模态优劣的肯定结论。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: The diagnostic accuracy of US and MRI for identifying peroneal tendon tears is unknown. The aim of this study is to determine the accuracy of these modalities for the diagnosis of peroneal tendon tears.

MATERIALS AND METHODS: Studies on diagnostic accuracy of MRI or US for peroneus brevis (PB) and/or longus pathology were searched in Scopus, EMBASE, and PubMed. Systematic review was performed using the QUADAS-2 tool. Pooled diagnostic accuracy of MRI and US were calculated by using a bivariate random-effects model.

RESULTS: Twelve studies were included for analysis. Eight studies reported on MRI, three reported on US, and one study included both. Studies were all at a high risk of bias, with only one study satisfying at least two of the four risk-of-bias criteria. Reported accuracy data was heterogeneous for both MRI and US. For PB tear, US showed higher pooled sensitivity than MRI (US: 93%; 95% CI: 75%, 98%; MRI: 73%; 95% CI: 56%, 87%); and similar pooled specificity to MRI (US: 85%; 95% CI: 55%, 96%; MRI: 88%; 95% CI: 70%, 95%) For peroneus longus, US had high pooled sensitivity (94%; 95% CI: 71%, 99%) and specificity (94%; 95% CI: 79%, 98%), whereas MRI was similarly specific (91%; 95% CI: 76%, 97%) but less sensitive (60%; 95% CI: 35%, 85%).

CONCLUSION: US was observed to be sensitive and specific for peroneal tendon tears, while MRI was found to be specific but insensitive. The scarcity of literature addressing this question and the heterogeneity of the results precluded any confident conclusion of the superiority/inferiority of either modality.

KEY POINTS: Question Peroneal tendon tears are a common cause of lateral ankle pain, but the accuracy of MRI and US for identifying these tears is unknown. Finding Pooled data shows US to be both sensitive and specific and MRI to be specific and insensitive for peroneal tendon tears; however, the literature is scarce, at risk of bias, and results are inconsistent. Clinical relevance MRI and US are commonly utilized to assess lateral ankle pain. Though pooled-data suggests that US may be more sensitive, confident conclusion of the diagnostic accuracy of these modalities is limited by the level-of and quality-of the available evidence.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Ghandour S, Mercer RW, Strahan JA, et al. Diagnostic accuracy of MRI and US for peroneal tendon tears: a systematic review and meta-analysis. Eur Radiol. 2025. PMID: 40035861. doi:10.1007/s00330-025-11472-w

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。