疑似卵巢肿块建议行MRI检查者:基于非增强MRI序列预测恶性的深度学习模型评估
回顾性纳入526例经组织病理学证实的卵巢肿块患者(良性327例、恶性199例),构建训练集367例与验证集159例,基于T1WI、T2WI、DWI评估四种深度学习模型区分良恶性的效能。四种模型AUC为0.8091至0.8572,准确率81.1%至85.5%;ResNet50敏感度最高(78.3%)、阴性预测值最高(87.3%),ConvNeXt特异度和阳性预测值达100%。模型优于低年资放射科医师(准确率69.2%),略低于高年资医师(86.2%),提示基于非增强MRI的深度学习模型有辅助诊断潜力。
要点
- 四种深度学习模型基于非增强MRI区分卵巢肿瘤良恶性,AUC 0.8091–0.8572,准确率81.1%–85.5%。
- ResNet50敏感度78.3%、阴性预测值87.3%最高;ConvNeXt特异度和阳性预测值达100%。
- 模型准确率高于低年资医师(69.2%),略低于高年资医师(86.2%)。
核心结论
- 四种深度学习模型基于非增强MRI能有效区分卵巢肿瘤良恶性,效能优于低年资放射科医师、略低于高年资医师;ResNet50预测性能最佳,GhostNet以更少参数实现高准确率;基于非增强MRI的深度学习模型有辅助诊断潜力。
研究设计与样本
- 回顾性研究纳入526例因疑似卵巢肿块建议行MRI并经组织病理学证实的患者(良性327例、恶性199例),构建训练集367例和验证集159例,基于T1WI、T2WI、DWI图像评估ConvNeXt、FBNet、GhostNet、ResNet50四种深度学习模型的诊断性能,并由两名不同经验水平的放射科医师独立判读验证集全部原始非增强MRI图像。
诊断标准与关键数值
- 四种深度学习模型预测恶性肿瘤的AUC为0.8091至0.8572,准确率为81.1%至85.5%;ResNet50敏感度78.3%、阴性预测值87.3%均为最高,ConvNeXt特异度和阳性预测值达100%;高年资放射科医师准确率86.2%,低年资放射科医师准确率69.2%。
临床应用与阅片要点
- 原文结论指出基于非增强MRI的深度学习模型有辅助诊断潜力;模型准确率高于低年资放射科医师(69.2%)、略低于高年资医师(86.2%),ResNet50预测性能最佳,GhostNet以更少参数实现高准确率。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: We aims to assessed and compare four deep learning(DL) models using non-contrast-enhanced magnetic resonance imaging(MRI) to differentiate benign from malignant ovarian tumors, considering diagnostic efficacy and associated development costs.
METHODS: 526 patients (327 benign lesions vs 199 malignant lesions) who were recommended for MRI due to suspected ovarian masses, confirmed with histopathology, were included in this retrospective study. A training cohort (n=367) and a validation cohort (n=159) were constructed. Based on the images of T1-weighted imaging (T1WI), T2-weighted imaging (T2WI), diffusion-weighted imaging (DWI), we evaluated the diagnostic performance of four DL models (ConvNeXt, FBNet, GhostNet, ResNet50) in distinguishing between benign and malignant ovarian tumors. Two radiologists with varying levels of experience independently reviewed all original non-contrast-enhanced MR images from the validation cohort to determine if each case was benign or malignant. The area under the receiver operating characteristic curve (AUC), confusion matrices, accuracy, sensitivity, specificity, positive predictive value(PPV) and negative predictive value(NPV) were used to compare performance.
RESULTS: The study of 526 ovarian mass patients (ages 1-92) evaluated four DL models for predicting malignant tumors, with AUCs ranging from 0.8091 to 0.8572 and accuracy between 81.1% and 85.5%. An experienced radiologist achieved 86.2% accuracy, slightly surpassing the DL models, while a less experienced radiologist had 69.2% accuracy. Resnet50 had the highest sensitivity (78.3%) and NPV (87.3%), while ConvNeXt excelled in specificity and PPV (100%). GhostNet and FBNet are more parameter-efficient than other models.
CONCLUSION: The four DL models effectively distinguished between benign and malignant ovarian tumors using non-contrast MRI. These models outperformed less experienced radiologists and were slightly less accurate than experienced ones. ResNet50 had the best predictive performance, while GhostNet was highly accurate with fewer parameters. Our study indicates that DL models based on non-contrast-enhanced MRI have the potential to assist in diagnosis.
引用
- Jiang M, Kong C, Lu S, et al. Ovarian masses suggested for MRI examination: assessment of deep learning models based on non-contrast-enhanced MRI sequences for predicting malignancy. Abdom Radiol (NY). 2025. PMID: 40116887. doi:10.1007/s00261-025-04891-2
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。