磁共振成像衍生的母体与胎儿参数与肩难产的相关性:匹配病例对照研究

Association of magnetic resonance imaging-derived maternal and fetal parameters with shoulder dystocia: matched case-control study.
PubMed 文献 · Ultrasound Obstet Gynecol · 2025-03-27

回顾性单中心匹配病例对照研究纳入1843例,肩难产63例(3.4%),匹配后病例组36例、对照组72例。MRI测量的胎儿体积、肩部皮肤间距及母体骨盆径线与肩难产相关,胎儿体积、肩部皮肤间距、双顶径、矢状出口径及最大横径为独立预测因子。

要点

  • 肩难产组胎儿体积及肩部皮肤间距高于对照组,母体产科结合径、矢状出口径、尾骨骨盆出口及最大横径低于对照组。
  • 胎儿体积、肩部皮肤间距、双顶径、矢状出口径及最大横径为肩难产的独立预测因子。
  • 非显著性肩难产者仅肩部皮肤间距显著增大、产科结合径显著降低;显著性肩难产者仅矢状出口径与最大横径显著降低。

核心结论

  • MRI衍生的胎儿大小、胎儿肩部测量及母体骨盆测量与肩难产相关,未来研究可将这些测量纳入可靠的预测模型。

研究设计与样本

  • 回顾性单中心病例对照研究,2015年1月至2022年12月,纳入1843例,肩难产63例(3.4%),按1:2匹配后病例组36例、对照组72例;由一名经验丰富和一名经验不足的医师盲法测量MRI参数,采用组内相关系数评估观察者间信度,统计显著性设为P<0.05。

关键影像表现/征象

  • 肩难产组胎儿体积高于对照组(P=0.023)。
  • 肩难产组肩部皮肤间距高于对照组(P=0.003)。
  • 肩难产组产科结合径低于对照组(P=0.021)。
  • 肩难产组矢状出口径低于对照组(P=0.004)。
  • 肩难产组尾骨骨盆出口低于对照组(P=0.045),最大横径低于对照组(P=0.001)。

诊断标准与关键数值

  • 肩难产定义依据皇家学院(Royal College)妇产科医师学会标准,显著性肩难产定义为McRoberts手法或耻骨上加压未能解决的肩难产。
  • 逻辑回归模型显示胎儿体积、肩部皮肤间距、双顶径、矢状出口径及最大横径为肩难产的独立预测因子。
  • 经验不足的读片者重复测量时,关注指标的信度为中等至优秀。

临床应用与阅片要点

  • 非显著性肩难产者仅肩部皮肤间距显著大于对照组、产科结合径显著低于对照组。
  • 显著性肩难产者仅矢状出口径和最大横径显著低于对照组。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To assess the association of fetal body measurements and maternal pelvic measurements obtained using magnetic resonance imaging (MRI) with the incidence of shoulder dystocia.

METHODS: This was a retrospective, single-center, case-control study conducted between January 2015 and December 2022. Patients whose delivery was complicated by shoulder dystocia and who underwent fetal MRI in the third trimester were included in the case group. Patients without shoulder dystocia who were delivered normally and who also underwent fetal MRI in the third trimester were included in the control group. Cases of multiple pregnancy, planned or emergency Cesarean delivery, fetal malformation or those with incomplete MRI examination were excluded. The case group was matched with the control group in a 1:2 ratio according to maternal age, maternal body mass index, gestational diabetes mellitus, diabetes mellitus Type 1 or 2, gestational age at MRI examination, gestational age at birth and birth weight. Shoulder dystocia was defined as per the Royal College of Obstetricians and Gynecologists and significant shoulder dystocia was defined as shoulder dystocia that was not resolved by the McRoberts' maneuver or suprapubic pressure. The following fetal and maternal measurements were quantified on MRI in both groups by two readers (one experienced and one inexperienced physician) who were blinded to the obstetric outcomes: fetal body volume (FBV), shoulder skin-to-skin distance, interhumeral distance, biparietal diameter (BPD), head circumference, obstetric conjugate (OC), sagittal outlet diameter (SOD), coccygeal pelvic outlet (CPO) and maximal transverse diameter (MTD). A stepwise backward logistic regression that included all measurements was performed. The inter-rater reliability of the measurements was estimated using interclass correlation coefficient (ICC). Statistical significance was set at P < 0.05.

RESULTS: Among the 1843 patients included in the study, there were 63 (3.4%) cases of shoulder dystocia. After matching, the case group comprised 36 patients and the control group comprised 72 patients. Patients who had shoulder dystocia, compared to those without, had higher FBV (P = 0.023), higher shoulder skin-to-skin distance (P = 0.003), lower OC (P = 0.021), lower SOD (P = 0.004), lower CPO (P = 0.045) and lower MTD (P = 0.001) in comparison with those without. The logistic regression model showed that FBV, shoulder skin-to-skin distance, BPD, SOD and MTD were independent predictors of shoulder dystocia. The measurements of interest had moderate to excellent reliability when repeated by an inexperienced reader. In those who had non-significant shoulder dystocia, only shoulder skin-to-skin distance was significantly greater and OC was significantly lower in comparison with the control group, whereas in those who had significant shoulder dystocia, only SOD and MTD were significantly lower in comparison with the control group.

CONCLUSIONS: MRI-derived fetal size, fetal shoulder measurements and maternal pelvimetry are associated with shoulder dystocia. Future studies could incorporate these measurements into a reliable predictive model for shoulder dystocia. © 2025 International Society of Ultrasound in Obstetrics and Gynecology.

来源:Ultrasound Obstet Gynecol,查看原文。版权归原作者所有。