文献速递泌尿生殖MR

探索多参数定量磁共振成像在避免PI-RADS 3-4患者不必要活检中的价值

Exploring the value of multiparametric quantitative magnetic resonance imaging in avoiding unnecessary biopsy in patients with PI-RADS 3-4.
PubMed 文献 · Abdom Radiol (NY) · 2025-03-26

本研究纳入96例PI-RADS v2.1评分3-4分且经病理证实的患者,评估APTw MRI、DKI和ADC对临床显著前列腺癌(csPCa)的诊断效能。联合模型AUC为0.851(95%CI: 0.767, 0.934),显著高于各单一参数(P < 0.05),在漏诊csPCa与避免不必要活检间取得最佳平衡(Youden=0.615)。

要点

  • APTw、DKI和ADC联合模型诊断csPCa的AUC为0.851,高于各单一序列。
  • 联合模型在漏诊csPCa与避免不必要活检间取得最佳平衡(Youden=0.615)。
  • 各单一参数中APT的AUC最高(0.730),MK最低(0.610)。

核心结论

  • 包含APTw-MRI、DKI和ADC的新型诊断模型对PI-RADS 3-4病灶的活检必要性分层提供增量诊断价值。

研究设计与样本

  • 研究纳入96例按PI-RADS v2.1评分为3-4分且经病理证实的参与者。
  • 由两名放射科医师和一名资深放射科医师获取APT、ADC、MD和MK值的均值。
  • 采用单因素和多因素logistic回归分析筛选参数,ROC分析评估模型性能,Delong检验比较模型间AUC。

诊断标准与关键数值

  • APT诊断csPCa的AUC为0.730(95%CI: 0.626, 0.834)。
  • MD诊断csPCa的AUC为0.682(95%CI: 0.562, 0.802)。
  • MK诊断csPCa的AUC为0.610(95%CI: 0.482, 0.739)。
  • ADC诊断csPCa的AUC为0.706(95%CI: 0.593, 0.819)。
  • 联合模型诊断csPCa的AUC为0.851(95%CI: 0.767, 0.934),显著高于其他模型(P < 0.05),Youden指数为0.615。

临床应用与阅片要点

  • 联合模型在PI-RADS 3-4患者中提供增量诊断价值,用于分层活检必要性。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To validate the performance of three multiparametric quantitative sequences, including amide proton transfer-weighted (APTw) MRI, diffusion kurtosis imaging (DKI) and apparent diffusion coefficient (ADC), in the enhancement of biopsy decision-making in patients with Prostate Imaging-Reporting and Data System (PI-RADS) core of 3-4.

MATERIALS AND METHODS: A total of 96 participants who scored as PI-RADS 3-4 according to PI-RADS v2.1 and pathologically confirmed were enrolled. The mean of APT, ADC, mean diffusivity (MD) and mean kurtosis (MK) values were acquired by two radiologists and a senior radiologist. The univariate and multivariate logistic regression analyses were performed for parameters selection. Receiver operating characteristic (ROC) analysis was employed to assess the performance of models. The Delong test was applied to compare the area under the ROC curves (AUCs) between models. The proportion of unnecessary biopsies avoided (specificity) and csPCa missed (1-sensitivity) were calculated for each model.

RESULTS: In this PI-RADS 3-4 cohort, the AUCs for the diagnosis of csPCa were 0.730 (95%CI: 0.626, 0.834), 0.682(95%CI: 0.562, 0.802), 0.610(95%CI: 0.482, 0.739) and 0.706(95%CI: 0.593, 0.819) for APT, MD, MK and ADC values, respectively. The combined model yielded the significantly higher AUC of 0.851 (95%CI: 0.767, 0.934) (P < 0.05), and achieved a best trade-off between missing csPCa and avoiding unnecessary biopsy than other models (Youden = 0.615).

CONCLUSION: A novel diagnostic model incorporating APTw-MRI, DKI and ADC has been shown to provide incremental diagnostic value in stratifying biopsy necessity for patients with PI-RADS 3-4 lesions.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Gong Z, Jiang F, Liu Z, et al. Exploring the value of multiparametric quantitative magnetic resonance imaging in avoiding unnecessary biopsy in patients with PI-RADS 3-4. Abdom Radiol (NY). 2025. PMID: 40137950. doi:10.1007/s00261-025-04901-3

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。