文献速递外周血管介入CT

优化下肢CT血管成像:个体化与固定触发后延迟在团注跟踪中的前瞻性研究

Optimizing lower extremity CT angiography: A prospective study of individualized vs. fixed post-trigger delays in bolus tracking.
PubMed 文献 · Eur J Radiol · 2025-02-25

前瞻性研究纳入65例下肢流出道CTA患者,比较固定触发延迟(30例,10秒)与个体化触发后延迟(35例,2–23秒,均值8.7±4.0秒)的对比剂充盈和诊断质量。个体化组在胫后动脉和足背动脉的CT值更高,主观图像质量评级更优。

要点

  • 个体化触发后延迟可提高下肢远端动脉(胫后动脉、足背动脉)的对比剂充盈。
  • 个体化组主观图像质量「优秀」或「良好」的比例高于固定延迟组。
  • 两组在人口学特征和辐射剂量方面无差异。

核心结论

  • 个体化触发后延迟通过改善外周动脉的血管充盈并提高下肢流出道CTA的主观图像质量,从而提升诊断质量。

研究设计与样本

  • 前瞻性研究,纳入65例患者(平均年龄71±14岁,39名男性),个体化组35例、固定组30例;两组CT协议、对比剂应用和图像重建相同;参考标准为客观图像质量(平均对比剂CT值,HU)和主观图像质量(5点Likert量表),评估6条血管:腹主动脉、髂总动脉、股浅动脉、腘动脉、胫后动脉和足背动脉;客观图像质量由1名评估者评估,主观图像质量由2名评估者评估。

关键影像表现/征象

  • 个体化组胫后动脉CT值为479±140 HU,固定组为379±106 HU(p=0.009)。
  • 个体化组足背动脉CT值为477±191 HU,固定组为346±137 HU(p=0.009)。

诊断标准与关键数值

  • 个体化触发后延迟范围为2至23秒(均值8.7±4.0秒),固定组为10秒。
  • 主观图像质量采用5点Likert量表评估。
  • 评估者1评为「优秀」或「良好」的比例:个体化组97% vs 固定组57%(p<0.001)。
  • 评估者2评为「优秀」或「良好」的比例:个体化组89% vs 固定组53%(p=0.002)。

临床应用与阅片要点

  • 采用个体化触发后延迟可改善下肢流出道CTA中外周动脉的对比剂充盈和主观图像质量。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To compare the contrast media opacification and diagnostic quality in lower-extremity runoff CT angiography (CTA) between bolus-tracking using conventional fixed trigger delay and patient-specific individualized post-trigger delay.

METHODS: In this prospective study, lower-extremity runoff CTA was performed in two cohorts, using either fixed or individualized trigger delay. Both cohorts had identical CT protocols, contrast media applications, and image reconstructions. Objective image quality (mean contrast opacification in HU), and subjective image quality (5-point Likert-scale), were assessed in six vessels: abdominal aorta (AA), common iliac artery (CIA), superficial femoral artery (SFA), popliteal artery (PA), posterior tibial artery (PTA), and dorsalis pedis artery (DPA) by one rater for objective and two raters for subjective image quality. Objective image quality was analyzed using Student t-tests, while subjective ratings were compared with Fisher's exact test.

RESULTS: Overall, 65 patients were included (mean age: 71 ± 14; 39 men), 35 in the individualized cohort and 30 in the fixed cohort. No differences were found between the groups regarding demographics or radiation exposure. Individualized trigger delay ranged from 2 to 23 s (mean: 8.7 ± 4.0 s) and was 10 s in the fixed cohort. The individualized cohort showed higher opacification in the peripheral arteries (PTA: 479 ± 140 HU vs. 379 ± 106 HU; p = 0.009; DPA: 477 ± 191 HU vs. 346 ± 137 HU; p = 0.009). Overall subjective "image quality" was rated higher in the individualized group ("excellent" or "good" in Rater 1: 97 % vs. 57 %; p < 0.001; and Rater 2: 89 % vs. 53 %; p = 0.002).

CONCLUSION: Individualized post-trigger delay enhances diagnostic quality, by improving vessel opacification in peripheral arteries and increasing subjective image quality in lower extremity runoff CTA.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Nas L, Hoppe BF, Stüber AT, et al. Optimizing lower extremity CT angiography: A prospective study of individualized vs. fixed post-trigger delays in bolus tracking. Eur J Radiol. 2025. PMID: 40022840. doi:10.1016/j.ejrad.2025.112009

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。