指南与共识腹部MR

胰腺囊肿的平均直径与单次最大直径同囊肿体积的关联及其对筛查指南分类的影响

Association of Average Cyst Diameter Versus Single Maximum Diameter of Pancreatic Cysts to Cyst Volume and Impact on Screening Guideline Classification.
指南 / 共识 · J Am Coll Radiol · 2025-01-01

回顾性纳入2017年MRCP上胰腺囊肿<3 cm的连续患者86例,比较单次最大直径与平均囊肿直径对分割囊肿体积的关联,并按现行筛查指南分别分类。平均囊肿直径与分割体积的相关性优于单次最大直径,采用平均直径使28%患者被归入随访策略较宽松的组。

要点

  • 平均囊肿直径较单次最大直径更准确反映分割囊肿体积(r=0.88 vs r=0.73)。
  • 采用平均囊肿直径按现行筛查指南分类,86例中24例(28%)被归入随访策略较宽松的组。
  • 测量者间一致性极好(r=0.99)。

核心结论

  • 平均囊肿直径较单次最大直径更准确地反映分割囊肿体积。
  • 在现行筛查指南中采用平均囊肿直径使28%患者被重新归入较低风险筛查组,总体上可减少后续 surveillance imaging。

研究设计与样本

  • 回顾性识别2017年MRCP上胰腺囊肿<3 cm的连续患者。
  • 在冠状位MRCP上测量囊肿单次最大直径及垂直短轴直径,取两者平均值作为平均囊肿直径。
  • 将基于单次最大直径和平均囊肿直径计算的体积近似值与分割囊肿体积比较。
  • 按现行筛查指南分别以平均囊肿直径与单次最大直径对患者分类。
  • 采用组内相关系数评估测量者间一致性,Williams检验比较组间相关系数。

诊断标准与关键数值

  • 纳入86个囊肿,单次最大直径均值15.4 ± 7.3 mm,平均囊肿直径均值12.6 ± 6.1 mm。
  • 分割囊肿体积均值1,521 ± 1,983 mm3。
  • 基于平均囊肿直径计算的体积与分割囊肿体积相关性(r=0.88)优于单次最大直径(r=0.73,P < .0001)。
  • 囊肿直径测量的测量者间一致性极好(r=0.99)。

临床应用与阅片要点

  • 阅片测量胰腺囊肿时,可同时记录单次最大直径与平均囊肿直径,后者与分割体积相关性更好。
  • 按现行筛查指南分类时,采用平均囊肿直径可使部分患者归入随访策略较宽松的组。

局限性

  • 原文为回顾性识别2017年连续患者。
  • 作者在讨论中指出平均囊肿直径在现有筛查指南中的应用使28%患者被重新归入较低风险筛查组。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To compare the association of single maximum diameter and average cyst diameter of pancreatic cysts measured on magnetic resonance cholangiopancreatography (MRCP) with segmented cyst volume and secondarily evaluate the effect of average cyst diameter on screening guideline classification.

METHODS: Consecutive patients with pancreatic cysts < 3 cm on MRCP in 2017 were retrospectively identified. The single maximum diameter and perpendicular short axis diameter of pancreatic cysts obtained on coronal MRCP were measured and their average was taken to determine average cyst diameter. Calculated volume approximations based on single maximum diameter and average cyst diameter were compared with segmented cyst volume. Subsequently, patients were classified based on average cyst diameter versus single maximum diameter according to a currently used screening guideline. Intraclass correlation was used to assess interobserver agreement. Williams's test was used to compare between-group correlation coefficients.

RESULTS: The mean value of single maximum diameters and average cyst diameter of the 86 included cysts were 15.4 ± 7.3 mm and 12.6 ± 6.1 mm, respectively. The mean volume of segmented cysts was 1,521 ± 1,983 mm3. Interreader agreement for measurement of cyst diameters was excellent (r = 0.99). The volume calculated based on the average cyst diameter correlated better to segmented cyst volume (r = 0.88) than single maximum diameter (r = 0.73, P < .0001). Of 86 patients, 24 (28%) were classified to a less stringent follow-up strategy by using average cyst diameter.

DISCUSSION: The average cyst diameter more accurately reflects the segmented cyst volume than a single maximum diameter. Utilization of average cyst diameter in existing screening guidelines reclassified 28% of patients into lower-risk screening groups, which would reduce subsequent surveillance imaging overall.

来源:J Am Coll Radiol,查看原文。版权归原作者所有。

引用

  1. Babapour S, Bezuidenhout AF, Handler M, et al. Association of Average Cyst Diameter Versus Single Maximum Diameter of Pancreatic Cysts to Cyst Volume and Impact on Screening Guideline Classification. J Am Coll Radiol. 2025. PMID: 40044311. doi:10.1016/j.jacr.2024.12.005

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。