文献速递腹部CTMRUS

光子计数CT衍生肝脂肪分数定量:一项临床验证研究

Photon-counting CT-derived Quantification of Hepatic Fat Fraction: A Clinical Validation Study.
PubMed 文献 · Radiology · 2025-01-01

这项前瞻性观察性临床研究在178名已知或疑似肝病患者中评估光子计数CT(PCCT)在增强扫描上定量肝脂肪分数的准确性,并与MRI质子密度脂肪分数(PDFF)、瞬时弹性成像受控衰减参数(CAP)和病理组织学分级进行验证。PCCT与MRI PDFF一致性极好(ICC 0.91),与组织学(ρ=0.65)和CAP(ρ=0.45)分级中度相关;基于Youden指数,区分有无脂肪变性的最佳PCCT脂肪分数阈值为4.8%,敏感度81%、特异度71%。

要点

  • PCCT虚拟平扫图像使用三物质分解算法可定量肝脂肪分数,与MRI PDFF一致性极好(ICC 0.91)。
  • PCCT区分有无脂肪变性的最佳阈值为4.8%,敏感度81%、特异度71%。
  • PCCT脂肪变分级与组织学(ρ=0.65)和CAP(ρ=0.45)呈中度相关。

核心结论

  • 在标准临床环境中,PCCT可准确估算肝脂肪分数,与MRI PDFF参考标准测量结果相比表现良好。

研究设计与样本

  • 前瞻性观察性临床研究,纳入178名已知或疑似肝病患者,于2022年2月至2024年1月接受PCCT检查;其中27人接受肝活检,26人接受CAP测量,125人接受MRI PDFF测量;PCCT采用虚拟平扫图像和针对脂肪、肝组织、碘的三物质分解算法。

诊断标准与关键数值

  • PCCT与MRI PDFF的组内相关系数为0.91(95%CI:0.87,0.94);在有纤维化参与者中ICC为0.84(95%CI:0.63,0.93),无纤维化参与者中ICC为0.92(95%CI:0.88,0.94);PCCT脂肪变分级与组织学分级Spearman ρ=0.65,与CAP分级ρ=0.45;基于Youden指数,区分有无脂肪变性的最佳PCCT脂肪分数阈值为4.8%,敏感度81%(38/47),特异度71%(55/78)。

临床应用与阅片要点

  • 作者指出PCCT在标准临床环境中可准确估算肝脂肪分数,与MRI PDFF参考标准相比表现良好。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background Steatosis is a critical health problem, creating a growing need for opportunistic screening. Early detection may allow for effective treatment and prevention of further liver complications. Purpose To evaluate photon-counting CT (PCCT) fat quantification on contrast-enhanced scans and validate the results against fat quantification via histopathologic assessment, controlled attenuation parameter (CAP) from transient elastography, and MRI proton density fat fraction (PDFF). Materials and Methods In this prospective, observational clinical study, PCCT-derived fat fraction quantification was assessed in participants with known or suspected liver disease. Participants underwent PCCT between February 2022 and January 2024. Participants also underwent biopsy, US with CAP measurement, or MRI with a PDFF sequence for hepatic fat fraction quantification. Liver fat fraction was measured on virtual noncontrast PCCT images using spectral processing software with a three-material decomposition algorithm for fat, liver tissue, and iodine. Steatosis was graded for each modality. Correlation between PCCT-based steatosis grades and biopsy- and CAP-based grades was assessed with the Spearman correlation coefficient. Agreement between PCCT and MRI PDFF measurements was assessed with the intraclass correlation coefficient. Receiver operating characteristic curve analysis was conducted to determine the optimal PCCT fat fraction threshold for distinguishing between participants with and those without steatosis. Results The study included 178 participants, of whom 27 (mean age, 60.7 years ± 15.2 [SD]; 18 male participants) underwent liver biopsy, 26 (mean age, 60.0 years ± 18.3; 15 male participants) underwent CAP measurement, and 125 (mean age, 61.2 years ± 13.1; 70 male participants) underwent MRI PDFF measurement. There was excellent agreement between PCCT and MRI PDFF assessment of liver fat fraction (intraclass correlation coefficient, 0.91 [95% CI: 0.87, 0.94]). In stratified analysis, the intraclass correlation coefficient was 0.84 (95% CI: 0.63, 0.93) in participants with known fibrosis and 0.92 (95% CI: 0.88, 0.94) in participants without fibrosis. There was moderate correlation of PCCT-based steatosis grade with histologic (ρ = 0.65) and CAP-based (ρ = 0.45) steatosis grade. Based on the Youden index, the PCCT fat fraction threshold that best discriminated between participants with and those without steatosis was 4.8%, with a maximum achievable sensitivity of 81% (38 of 47) and a specificity of 71% (55 of 78). Conclusion PCCT in a standard clinical setting allowed for accurate estimation of liver fat fraction compared with MRI PDFF-based reference standard measurements. © RSNA, 2025 See also the editorial by Kartalis and Grigoriadis in this issue.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Dell T, Mesropyan N, Layer Y, et al. Photon-counting CT-derived Quantification of Hepatic Fat Fraction: A Clinical Validation Study. Radiology. 2025. PMID: 40100026. doi:10.1148/radiol.241677

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。