文献速递心血管CT

不同斑块类型及其与冠状动脉周围脂肪组织体积和衰减值的关联:基于冠状动脉CT血管成像的评估

Different plaque types and its association with the volume and attenuation of pericoronary adipose tissue as assessed by coronary computed tomography angiography.
PubMed 文献 · Clin Radiol · 2025-01-15

本研究纳入321例稳定型冠心病患者,基于CCTA测量斑块周围、所在节段及近段冠状动脉的PCAT体积与CT衰减值,比较不同斑块类型间的差异。共分析552个病变,钙化斑块与非钙化斑块的斑块周围PCAT体积及衰减值存在显著差异,且以斑块周围测量差异尤为明显。

要点

  • 非钙化斑块周围PCAT衰减值高于钙化斑块(-73.00 HU vs -85.00 HU,P<0.05)。
  • 钙化斑块斑块周围PCAT体积大于非钙化斑块(291.98 mm³ vs 206.54 mm³,P<0.05)。
  • 斑块周围PCAT测量差异较所在节段及近段冠状动脉更显著。

核心结论

  • 不同斑块类型间PCAT体积和衰减值存在显著差异,且斑块周围测量的差异尤为显著。

研究设计与样本

  • 回顾性纳入2022年5月至2023年3月行CCTA的321例稳定型冠心病患者,使用半自动软件测量斑块周围、所在节段及近段冠状动脉的PCAT体积和CT衰减值。

临床应用与阅片要点

  • 测量斑块周围PCAT体积和衰减值时需注意斑块类型对数值的影响。
  • 两位放射科医生测量PCAT体积和衰减值的组内相关系数均>0.80,一致性极好。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To explore the relationship between different plaque types and pericoronary adipose tissue (PCAT) volume and attenuation values in patients with stable coronary artery disease (CAD) based on coronary computed tomographic angiography (CCTA).

MATERIALS AND METHODS: Three hundred twenty one patients with stable CAD who underwent CCTA from May 2022 to March 2023 were enrolled. Using semi-automatic software, PCAT volumes and CT attenuation values were measured around the plaque and in the segment and proximal coronary artery where the plaque was located. To compare whether there was a statistical difference in PCAT volume and attenuation values among different plaque types in the periplaque, the segment, and proximal coronary artery in which the plaque was positioned.

RESULTS: In total, 552 lesions were included, with 299 calcified plaques (CPs), 174 noncalcified plaques (NCPs), and 79 mixed plaques (MPs). There were excellent agreements between the two radiologists regarding the measured PCAT volumes and attenuation values (all interclass correlation coefficients values > 0.80). The periplaque PCAT volume was larger in CPs and MPs than in NCPs (291.98[213.25,381.03] mm3 vs. 261.00[173.25,377.85] mm3 vs. 206.54[139.72,284.07] mm3, P < 0.05), and the PCAT attenuation values around the plaque and the segment in which the plaque was positioned were higher in NCPs and MPs compared with CPs (-73.00[-79.00,-68.00] HU vs. -76.00[-79.00,-71.00] HU vs. -85.00[-92.00,-80.00] HU, -81.72 ± 0.70 HU vs. -80.73 ± 1.03 HU vs. -84.31 ± 0.49 HU; P < 0.05).

CONCLUSION: PCAT volume and attenuation values differed significantly among different plaque types, and the differences are particularly significant in measurements around the plaque.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Sun Q, Jing M, Xi H, et al. Different plaque types and its association with the volume and attenuation of pericoronary adipose tissue as assessed by coronary computed tomography angiography. Clin Radiol. 2025. PMID: 40069975. doi:10.1016/j.crad.2025.106814

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。