冠状动脉CT血管成像中不同狭窄量化方法的阅片者间与阅片者内一致性评估
回顾性纳入2023年一年内临床指征行CCTA且CAD-RADS 2.0评分为3或4的连续患者61例,由5名放射科医生分别用视觉法、直径法和面积法评估最严重冠状动脉狭窄。各法阅片者间一致性均为中等(Krippendorff α 0.42、0.46、0.41),阅片者内一致性中等至较佳(0.67、0.57、0.53);钙化评分高者一致性似有降低趋势。
要点
- 视觉、直径、面积三种狭窄量化方法的阅片者间一致性均为中等,方法间无显著差异。
- 阅片者内一致性视觉法0.67、直径法0.57、面积法0.53,为中等至较佳。
- 高钙化评分狭窄的一致性似有降低趋势,如视觉法非钙化与钙化组0.44 vs 0.2。
核心结论
- CCTA狭窄量化的阅片者间和阅片者内一致性总体为中等,视觉法与客观测量法之间无显著差异;钙化评分较高的狭窄一致性似有降低趋势。
研究设计与样本
- 回顾性研究,纳入2023年一年内临床指征行CCTA且CAD-RADS 2.0评分为3或4的连续患者61例(平均年龄65±10岁,18名女性),由5名放射科医生(其中3名心脏影像亚专科)独立评估最严重冠状动脉狭窄。
诊断标准与关键数值
- 视觉法、直径法、面积法百分比狭窄的阅片者间Krippendorff α分别为0.42、0.46、0.41;一名亚专科放射科医生的阅片者内α分别为0.67、0.57、0.53;视觉法阅片者间一致性非钙化狭窄(CACS=0)0.44 vs 钙化狭窄(CACS≥100)0.2。
局限性
- 本研究为回顾性研究。
- 高钙化评分狭窄的一致性降低仅为趋势观察。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To assess the inter- and intrareader agreement among different subjective and objective measurement methods to grade coronary artery stenosis in coronary CT angiography (CCTA).
METHODS: In this retrospective study, consecutive patients of a one-year cohort who received a clinically indicated CCTA in 2023 and had a CAD-RADS2.0 score of 3 or 4 were included. Five different radiologists (three subspecialized in cardiac imaging) independently graded the most severe coronary artery stenosis using different measurement methods: visual stenosis grading and objective stenosis grading measuring stenosis diameter and area. Interreader agreement of percentage stenosis were calculated for each measurement method and stratified by the coronary calcium score (CACS) using Krippendorf α. Intrareader assessment was performed for one subspecialized radiologist.
RESULTS: A total of 61 patients were included (mean age, 65 ± 10 years; 18 women). Interreader agreements for percentage stenoses as determined visually and as measured by diameter and area were moderate independent of measurement method (0.42, 0.46, 0.41 for visual, diameter and area percentage stenoses, respectively) and did not depend on subspecialization. Intrareader agreement was moderate to substantial with values of 0.67, 0.57 and 0.53 for visual, diameter and area percentage stenoses. There was a trend towards lower inter- and intrareader agreement for stenoses with high CACS (e.g. for visual grading: 0.44 vs. 0.2 for interreader agreement between non-calcified stenoses (CACS = 0) and calcified stenoses (CACS ≥ 100)).
CONCLUSION: Inter- and intrareader agreement for stenosis quantification in coronary CT angiography was overall moderate and did not differ significantly among visual and objective measurement methods. A trend towards lower agreement was observed for stenoses with higher CACS.
引用
- Rovetto C, Niemann T, Almeida G, et al. Assessment of inter- and intrareader agreement among different stenosis quantification methods in coronary CT angiography. Eur J Radiol. 2025. PMID: 40127592. doi:10.1016/j.ejrad.2025.112059
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。