基于深度学习的超分辨率重建对Agatston评分的影响
连续纳入111例接受心脏CT(含用于Agatston评分的不增强CT)的患者,用滤波反投影(FBP)和三种强度的DLSRR重建四类非增强CT图像。DLSRR显著降低图像噪声并提升SNR、CNR和ERS,对Agatston评分和CAC体积无显著影响,FBP与DLSRR的CAC-DRS分类一致率为93%,但观察到部分重新分类。
要点
- DLSRR显著降低图像噪声并提升SNR、CNR和ERS,强度越高降噪与SNR/CNR改善越明显。
- DLSRR对Agatston评分和CAC体积无显著影响(p=0.952和0.901)。
- FBP与DLSRR的CAC-DRS分类一致率为93%,但存在部分重新分类,临床应谨慎使用DLSRR。
核心结论
- DLSRR通过降低噪声和增强锐度显著改善图像质量,且不显著改变Agatston评分或CAC体积;与FBP的CAC-DRS分类一致率高,但观察到部分重新分类。
研究设计与样本
- 连续纳入接受心脏CT(含用于Agatston评分的不增强CT)的患者111例,用FBP和三种强度DLSRR重建四类非增强CT图像并进行比较。
关键影像表现/征象
- DLSRR显著降低图像噪声(p < 0.001),且强度越高降噪效果越强(p < 0.01)。
- DLSRR显著提升主动脉SNR和CNR(p < 0.001),强度越高提升越明显(p < 0.01)。
- DLSRR较FBP显著增强冠状动脉钙化边缘上升斜率(ERS)(p < 0.001),但三种DLSRR强度间无显著差异(p = 0.90-0.98)。
诊断标准与关键数值
- Agatston评分和CAC体积不受DLSRR显著影响(p = 0.952和0.901)。
- 基于CAC-DRS将患者分为四个风险等级,FBP与DLSRR的CAC-DRS分类一致率为93%。
临床应用与阅片要点
- DLSRR可改善非增强心脏CT图像质量,但Agatston评分和CAC体积与FBP相比无显著改变。
- 由于存在部分CAC-DRS重新分类,DLSRR在临床使用时应谨慎。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To evaluate the impact of deep learning-based super-resolution reconstruction (DLSRR) on image quality and Agatston score.
METHODS: Consecutive patients who underwent cardiac CT, including unenhanced CT for Agatston scoring, were enrolled. Four types of non-contrast CT images were reconstructed using filtered back projection (FBP) and three strengths of DLSRR. Image quality was assessed by measuring image noise, signal-to-noise ratio (SNR) of the aorta, contrast-to-noise ratio (CNR), and edge rise slope (ERS) of coronary artery calcium (CAC). Agatston score and CAC volume were also measured. These results were compared among the four CT datasets. Patients were categorized into four risk levels based on the Coronary Artery Calcium Data and Reporting System (CAC-DRS), and the concordance rate between FBP and DLSRR classifications was evaluated.
RESULTS: For the 111 patients enrolled, DLSRR significantly reduced image noise (p < 0.001) and improved SNR and CNR (p < 0.001), with stronger effects at higher DLSRR strengths (p < 0.01). ERS was significantly enhanced using DLSRR compared with FBP (p < 0.001), whereas there was no significant difference among the three strengths of DLSRR (p = 0.90-0.98). Agatston score and CAC volume were not significantly affected by DLSRR (p = 0.952 and 0.901, respectively). The concordance rate of CAC-DRS classification between FBP and DLSRR was 93%.
CONCLUSION: DLSRR significantly improves image quality by reducing noise and enhancing sharpness without significantly altering Agatston scores or CAC volumes. The concordance rate of CAC-DRS classification with FBP was high, although some reclassifications were observed.
KEY POINTS: Question The utility of deep learning-based super-resolution reconstruction (DLSRR) in coronary CT angiography is well known, but its impact on the Agatston score remains unclear. Findings DLSRR significantly improved image quality without altering the Agatston scores, but some reclassifications of Coronary Artery Calcium Data and Reporting System (CAC-DRS) were observed. Clinical relevance DLSRR should be cautiously used in clinical settings owing to the occurrence of some cases of CAC-DRS reclassification.
引用
- Morikawa T, Tanabe Y, Suekuni H, et al. Influence of deep learning-based super-resolution reconstruction on Agatston score. Eur Radiol. 2025. PMID: 40108013. doi:10.1007/s00330-025-11506-3
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。