文献速递心血管外周血管CTDSA

基于深度学习现场计算CT衍生血流储备分数与冠状动脉CT血管成像对冠心病治疗管理及结局的比较

CT-derived fractional flow reserve on therapeutic management and outcomes compared with coronary CT angiography in coronary artery disease.
PubMed 文献 · Br J Radiol · 2025-01-01

单中心前瞻性随机研究纳入461例疑似冠心病患者,比较CT-FFR联合CCTA与单纯CCTA对侵入性冠状动脉造影效率和2年主要不良心血管事件的影响。CT-FFR联合CCTA组非阻塞性病变ICA率低于单纯CCTA组(14.7% vs 34.0%,P=.047),血运重建与ICA比值更高(73.5% vs 50.9%,P=.036);2年MACE发生率两组无显著差异(5.9% vs 10.0%,P=.095)。

要点

  • CT-FFR联合CCTA较单纯CCTA降低非阻塞性病变ICA率(14.7% vs 34.0%,P=.047)。
  • CT-FFR联合CCTA组血运重建与ICA比值高于单纯CCTA组(73.5% vs 50.9%,P=.036)。
  • 2年MACE发生率两组无显著差异(5.9% vs 10.0%,P=.095)。

核心结论

  • 基于深度学习现场计算的CT-FFR较单纯CCTA提高了ICA利用效率,且2年MACE发生率相似且较低。

研究设计与样本

  • 单中心前瞻性研究,纳入2021年6月至2021年9月本院连续疑似冠心病患者461例,随机分为CT-FFR联合CCTA组与单纯CCTA组。

诊断标准与关键数值

  • 非阻塞性病变定义为ICA示狭窄<50%,90天内CT-FFR联合CCTA组非阻塞性病变ICA率为14.7%,单纯CCTA组为34.0%(P=.047)。
  • 90天内血运重建与ICA比值CT-FFR联合CCTA组为73.5%,单纯CCTA组为50.9%(P=.036)。
  • 中段狭窄(25%-69%)患者中两组ICA效率各项指标均无显著差异(所有P>.05)。
  • 中位随访23(22-24)个月,MACE在CT-FFR联合CCTA组观察11例、单纯CCTA组24例(5.9% vs 10.0%,P=.095)。

临床应用与阅片要点

  • 作者结论认为基于深度学习现场计算的CT-FFR较单纯CCTA在治疗管理方面更优。
  • 作者结论认为CT-FFR联合CCTA提高了ICA利用效率,且MACE发生率与单纯CCTA相似且较低。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To determine the value of on-site deep learning-based CT-derived fractional flow reserve (CT-FFR) for therapeutic management and adverse clinical outcomes in patients suspected of coronary artery disease (CAD) compared with coronary CT angiography (CCTA) alone.

METHODS: This single-centre prospective study included consecutive patients suspected of CAD between June 2021 and September 2021 at our hospital. Four hundred and sixty-one patients were randomized into either CT-FFR+CCTA or CCTA-alone group. The first endpoint was the invasive coronary angiography (ICA) efficiency, defined as the ICA with nonobstructive disease (stenosis <50%) and the ratio of revascularization to ICA (REV-to-ICA ratio) within 90 days. The second endpoint was the incidence of major adverse cardiaovascular events (MACE) at 2 years.

RESULTS: A total of 461 patients (267 [57.9%] men; median age, 64 [55-69]) were included. At 90 days, the rate of ICA with nonobstructive disease in the CT-FFR+CCTA group was lower than in the CCTA group (14.7% vs 34.0%, P=.047). The REV-to-ICA ratio in the CT-FFR+CCTA group was significantly higher than in the CCTA group (73.5% vs. 50.9%, P=.036). No significant difference in ICA efficiency was found in intermediate stenosis (25%-69%) between the 2 groups (all P>.05). After a median follow-up of 23 (22-24) months, MACE were observed in 11 patients in the CT-FFR+CCTA group and 24 in the CCTA group (5.9% vs 10.0%, P=.095).

CONCLUSIONS: The on-site deep learning-based CT-FFR improved the efficiency of ICA utilization with a similarly low rate of MACE compared with CCTA alone.

ADVANCES IN KNOWLEDGE: The on-site deep learning-based CT-FFR was superior to CCTA for therapeutic management.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Qian Y, Chen M, Hu C, et al. CT-derived fractional flow reserve on therapeutic management and outcomes compared with coronary CT angiography in coronary artery disease. Br J Radiol. 2025. PMID: 40107975. doi:10.1093/bjr/tqaf055

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。