基于低剂量计算机断层扫描的骨密度自动快速预测
本研究纳入551例同时接受低剂量胸部CT(LDCT)和定量CT(QCT)检查的受试者,开发U-net自动分割腰椎并构建深度学习模型预测体积骨密度(vBMD)及分类骨质疏松(OP)和骨量减少(OA)。分割模型平均Dice相似系数0.974;预测vBMD与QCT-derived vBMD的均方根误差8.958 mg/mm3、R2 0.944;检测OP和OA的曲线下面积分别为0.800和0.878,总体准确率94.2%,平均处理时间1.5秒。
要点
- U-net自动分割腰椎与手动分割的平均Dice相似系数为0.974,灵敏度0.964,阳性预测值0.985。
- 预测vBMD与QCT-derived vBMD的均方根误差为8.958 mg/mm3,R2为0.944。
- 检测骨质疏松和骨量减少的曲线下面积分别为0.800和0.878,总体准确率94.2%。
核心结论
- 该预测系统可在LDCT扫描上自动估计vBMD并检测骨质疏松和骨量减少,为骨质疏松筛查提供了很大潜力。
研究设计与样本
- 本研究纳入551例同时接受LDCT和QCT检查的受试者,开发U-net从椎体中部水平的单张2D LDCT切片自动分割腰椎,并构建预测模型估计vBMD用于检测骨质疏松和骨量减少,以QCT-derived vBMD为参考。
诊断标准与关键数值
- 分割模型在测试集上与手动分割的平均Dice相似系数为0.974,灵敏度为0.964,阳性预测值为0.985,Hausdorff距离为3.261。
- 双通道输入预测的vBMD与QCT-derived vBMD的均方根误差为8.958 mg/mm3,R2为0.944。
- 检测骨质疏松的曲线下面积为0.800,检测骨量减少的曲线下面积为0.878,总体准确率为94.2%。
- 系统平均处理时间为1.5秒。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: Low-dose chest CT (LDCT) is commonly employed for the early screening of lung cancer. However, it has rarely been utilized in the assessment of volumetric bone mineral density (vBMD) and the diagnosis of osteoporosis (OP).
PURPOSE: This study investigated the feasibility of using deep learning to establish a system for vBMD prediction and OP classification based on LDCT scans.
METHODS: This study included 551 subjects who underwent both LDCT and QCT examinations. First, the U-net was developed to automatically segment lumbar vertebrae from single 2D LDCT slices near the mid-vertebral level. Then, a prediction model was proposed to estimate vBMD, which was subsequently employed for detecting OP and osteopenia (OA). Specifically, two input modalities were constructed for the prediction model. The performance metrics of the models were calculated and evaluated.
RESULTS: The segmentation model exhibited a strong correlation with manual segmentation, achieving a mean Dice similarity coefficient (DSC) of 0.974, sensitivity of 0.964, positive predictive value (PPV) of 0.985, and Hausdorff distance of 3.261 in the test set. Linear regression and Bland-Altman analysis demonstrated strong agreement between the predicted vBMD from two-channel inputs and QCT-derived vBMD, with a root mean square error of 8.958 mg/mm3 and an R2 of 0.944. The areas under the curve for detecting OP and OA were 0.800 and 0.878, respectively, with an overall accuracy of 94.2%. The average processing time for this system was 1.5 s.
CONCLUSION: This prediction system could automatically estimate vBMD and detect OP and OA on LDCT scans, providing great potential for the osteoporosis screening.
引用
- Zhou K, Xin E, Yang S, et al. Automated Fast Prediction of Bone Mineral Density From Low-dose Computed Tomography. Acad Radiol. 2025. PMID: 40082126. doi:10.1016/j.acra.2025.02.041
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。