回顾性研究纳入2023年9月至11月接受CT引导下微弹簧圈定位并后续行电视辅助胸腔镜手术切除的118例患者,比较千叶针组(75例)与套管针组(43例)的安全性和有效性。两组定位成功率无显著差异(97.3% vs 100%,p=0.533),气胸发生率无显著差异(16% vs 18.6%,p=0.914),套管针组肺实质出血发生率较高(25.3% vs 41.9%,p=0.098),多因素回归显示套管针是肺实质出血的危险因素(p=0.035),穿刺深度较长是气胸(p=0.027)和肺实质出血(p=0.006)的危险因素。

要点

  • 千叶针与套管针定位成功率无显著差异(97.3% vs 100%,p=0.533)。
  • 套管针组肺实质出血发生率41.9%,千叶针组25.3%(p=0.098),套管针为肺实质出血危险因素(p=0.035)。
  • 穿刺深度较长是气胸(p=0.027)和肺实质出血(p=0.006)的危险因素。

核心结论

  • 千叶针与套管针在术前CT引导下肺结节定位的有效性无显著差异,两者成功率均高且气胸发生率相当,但套管针与较高的肺实质出血发生率相关。

研究设计与样本

  • 回顾性研究,纳入2023年9月至11月接受CT引导下微弹簧圈定位并后续行电视辅助胸腔镜手术切除的118例患者,分为千叶针组(n=75)和套管针组(n=43),采用单因素和多因素logistic回归分析技术失败和并发症的潜在危险因素。

诊断标准与关键数值

  • 定位成功率:千叶针组97.3%,套管针组100%,两组无显著差异(p=0.533)。
  • 气胸发生率:千叶针组16%,套管针组18.6%(p=0.914)。
  • 肺实质出血发生率:千叶针组25.3%,套管针组41.9%(p=0.098)。
  • 多因素logistic回归:穿刺深度较长是气胸的危险因素(p=0.027),穿刺深度较长是肺实质出血的危险因素(p=0.006),套管针是肺实质出血的危险因素(p=0.035)。

临床应用与阅片要点

  • 原文结论指出千叶针与套管针定位有效性无显著差异,两者成功率均高且气胸发生率相当,但套管针与较高的肺实质出血发生率相关。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To compare the relative safety and efficacy of the Chiba needle and the Trocar needle in CT-guided microcoil localization of pulmonary nodules.

METHODS: A retrospective study was conducted on 118 patients who underwent CT-guided microcoil localization and subsequent video-assisted thoracoscopic surgery (VATS) resection from September to November 2023. Patients were divided into the Chiba needle group (n = 75) and the Trocar needle group (n = 43). Characteristics of patients, lesions, procedures, and surgeries were statistically analyzed. Univariate and multivariate logistic regression analyses were used to determine potential risk factors for technical failure and complications.

RESULTS: The success rate of localization was 97.3 % for the Chiba needle group and 100 % for the Trocar needle group, with no significant difference (p = 0.533). Complications included pneumothorax in 16 % of the Chiba group and 18.6 % of the Trocar group (p = 0.914), and parenchymal hemorrhage in 25.3 % and 41.9 % respectively (p = 0.098). There were no significant differences in puncture depth, procedure duration, or interval between procedure and surgery. Multivariate logistic regression analyses identified longer puncture depth as a risk factor both for pneumothorax (p = 0.027) and parenchymal hemorrhage (p = 0.006), while the Trocar needle was identified as a risk factor for parenchymal hemorrhage (p = 0.035).

CONCLUSION: This study found no significant difference in the effectiveness of Chiba and Trocar needles for preoperative CT-guided lung nodule localization. Both needles showed high success rates and comparable pneumothorax profiles. However, the Trocar needle was found associated with a higher incidence of parenchymal hemorrhage.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Zeng Y, Xu L, Liu T, et al. Preoperative CT-guided lung nodule localization: Comparison of Chiba needle and Trocar needle. Eur J Radiol. 2025. PMID: 40112355. doi:10.1016/j.ejrad.2025.112053

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。