文献速递头颈神经CT

在尸体头骨中评估超高分辨率CT与锥形束CT及高分辨率CT对镫骨成像质量的比较

Evaluation of Stapes Image Quality with Ultra-High-Resolution CT in Comparison with Conebeam CT and High-Resolution CT in Cadaveric Heads.
PubMed 文献 · AJNR Am J Neuroradiol · 2025-09-02

研究用11例颞骨标本,以微型CT为参考,比较高分辨率CT、超高分辨率CT(含或不含深度学习重建)及锥形束CT对镫骨的成像质量。超高分辨率CT主观图像质量优于锥形束CT,客观测量与锥形束CT相当,但辐射剂量为锥形束CT的4倍;高分辨率CT表现最差。

要点

  • 超高分辨率CT主观评分优于锥形束CT,客观测量与微型CT无显著差异。
  • 高分辨率CT客观测量多数与微型CT有差异,表现最差。
  • 超高分辨率CT辐射剂量为锥形束CT的4倍。

核心结论

  • 超高分辨率CT(含或不含深度学习重建)提供与锥形束CT相当的客观图像分析,同时主观图像质量更优,但以更高辐射剂量为代价;锥形束CT和超高分辨率CT在客观和主观分析上均优于高分辨率CT。

研究设计与样本

  • 研究论文,11例颞骨标本,采用高分辨率CT、超高分辨率CT(含或不含深度学习重建)及锥形束CT成像,以微型CT为参考标准。

诊断标准与关键数值

  • 全局图像质量评分均低于微型CT(P ≤ .01);超高分辨率CT含或不含深度学习重建评分第二好(P > .99),均优于锥形束CT(两者P = .01);锥形束CT优于高分辨率CT(P = .01)。
  • 高分辨率CT与微型CT之间多数测量有差异(P ≤ .02);超高分辨率CT含或不含深度学习重建、锥形束CT与微型CT之间无差异(P > .06)。
  • 超高分辨率CT含深度学习重建的空气噪声值与锥形束CT无差异(P = .49);高分辨率CT和超高分辨率CT不含深度学习重建的噪声值高于超高分辨率CT含深度学习重建(P ≤ .001)。
  • 高分辨率CT和超高分辨率CT含或不含深度学习重建的有效辐射剂量均为1.23 ± 0.11(1.13-1.35)mSv,为锥形束CT(0.35 ± 0 mSv)的4倍(P ≤ .01)。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Conventional CT imaging techniques are ineffective in adequately depicting the stapes. The purpose of this study was to evaluate the ability of high-resolution (HR), ultra-high-resolution (UHR) with and without deep learning reconstruction (DLR), and conebeam (CB)-CT scanners to image the stapes by using micro-CT as a reference.

MATERIALS AND METHODS: Eleven temporal bone specimens were imaged by using all imaging modalities. Subjective image analysis was performed by grading image quality on a Likert scale, and objective image analysis was performed by taking various measurements of the stapes superstructure and footplate. Image noise and radiation dose were also recorded.

RESULTS: The global image quality scores were all worse than micro-CT (P ≤ .01). UHR-CT with and without DLR had the second-best global image quality scores (P > .99), which were both better than CB-CT (P = .01 for both). CB-CT had a better global image quality score than HR-CT (P = .01). Most of the measurements differed between HR-CT and micro-CT (P ≤ .02), but not between UHR-CT with and without DLR, CB-CT, and micro-CT (P > .06). The air noise value of UHR-CT with DLR was not different from CB-CT (P = .49), but HR-CT and UHR-CT without DLR exhibited higher values than UHR-CT with DLR (P ≤ .001). HR-CT and UHR-CT with and without DLR yielded the same effective radiation dose values of 1.23 ± 0.11 (1.13-1.35) mSv, which was 4 times higher than that of CB-CT (0.35 ± 0 mSv, P ≤ .01).

CONCLUSIONS: UHR-CT with and without DLR offers comparable objective image analysis to CB-CT while providing superior subjective image quality. However, this is achieved at the cost of a higher radiation dose. Both CB-CT and UHR-CT with and without DLR are more effective than HR-CT in objective and subjective image analysis.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Puel U, Boukhzer S, Doyen M, et al. Evaluation of Stapes Image Quality with Ultra-High-Resolution CT in Comparison with Conebeam CT and High-Resolution CT in Cadaveric Heads. AJNR Am J Neuroradiol. 2025. PMID: 40127966. doi:10.3174/ajnr.A8748

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。