合成MRI在鉴别头颈部鳞状细胞癌转移性与非转移性淋巴结中的价值:与DWI及主观经验的比较
本研究纳入149枚病理证实的淋巴结(转移58枚、非转移91枚),按7:3分为训练集与独立验证集,基于合成MRI直方图参数、ADC值及淋巴结短长径构建模型。验证集中SyMRI模型、DWI及联合模型AUC分别为0.882、0.755、0.952,联合模型准确率训练集0.905、验证集0.864,诊断效能优于多位放射科医师主观经验(验证集AUC 0.952 vs 0.705~0.845;亚厘米淋巴结AUC 0.878 vs 0.429~0.628,均P<0.001)。
要点
- 联合合成MRI直方图参数、ADC值与淋巴结大小的模型在验证集AUC达0.952,准确率0.864。
- 亚厘米淋巴结中联合模型AUC 0.878,优于主观经验AUC 0.429~0.628(P<0.001)。
- 合成MRI直方图参数单独鉴别转移与非转移淋巴结的验证集AUC为0.882。
核心结论
- 基于合成MRI的直方图参数可用于鉴别头颈部鳞状细胞癌患者的转移性与非转移性颈部淋巴结,与DWI及大小联合时诊断效能最佳。
研究设计与样本
- 共纳入149枚病理证实的淋巴结(转移性58枚、非转移性91枚),按7:3随机分为训练集与独立验证集,获取合成MRI直方图参数、ADC值及淋巴结短长径,采用逻辑回归构建模型并以ROC分析评估诊断效能。
诊断标准与关键数值
- 验证集中SyMRI模型、DWI模型与联合模型的AUC分别为0.882、0.755、0.952。
- 联合模型在训练集与验证集的准确率分别为0.905与0.864。
- 验证集联合模型AUC 0.952 vs 多位放射科医师主观经验AUC 0.705~0.845(P<0.001)。
- 亚厘米淋巴结联合模型AUC 0.878 vs 主观经验AUC 0.429~0.628(P<0.001)。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To explore the role of Synthetic MRI (SyMRI) histogram parameters in differentiating metastatic from non-metastatic cervical lymph nodes (LNs) in head and neck squamous cell carcinoma (HNSCC) patients, and construct a practical model.
METHODS: A total of 149 pathologically confirmed LNs (metastatic LNs: 58, non-metastatic LNs: 91) were included in the study. LNs were stratified and randomly divided into a training set and an independent validation set in a ratio of 7:3. Histogram parameters derived from SyMRI, ADC values, and the short and long diameters of each LN were obtained. Significantly different parameters between metastatic and non-metastatic LNs were selected in the training set, and logistic regression analysis was adopted to construct different models. ROC analysis and AUC were performed to assess the diagnostic performance of different models and subjective analysis.
RESULTS: The AUCs of the three models were 0.882 (SyMRI_model), 0.755 (DWI), and 0.952 (Combined_model) in the validation set. The Combined_model, constructed based on SyMRI, ADC values, and size, had the highest diagnostic potency in both training and validation sets, with an accuracy of 0.905 and 0.864 in the two sets, respectively. The diagnostic performance of the Combined_model was superior to multi-radiologists' subjective experience, not only in LNs from validation set (AUC: 0.952 vs. 0.705 ∼ 0.845) but also in the cohort of sub-centimeter LNs (AUC: 0.878 vs. 0.429 ∼ 0.628) (all P < 0.001).
CONCLUSION: Histogram parameters derived from SyMRI are feasible in discriminating metastatic from non-metastatic cervical LNs in HNSCC, and the diagnostic efficacy is optimal when combined with DWI and size.
引用
- Wei H, Yang F, Li Y, et al. The value of Synthetic MRI in discriminating metastatic and non-metastatic lymph nodes in head and neck squamous cell carcinoma, compared with DWI and subjective experience. Eur J Radiol. 2025. PMID: 40121896. doi:10.1016/j.ejrad.2025.112048
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。