文献速递头颈技术与安全MR

基于MRI的Node-RADS预测头颈部鳞状细胞癌转移性淋巴结受累的准确性

Accuracy of MRI-based Node-RADS in predicting metastatic lymph node involvement in Head and Neck Squamous Cell Carcinoma.
PubMed 文献 · Eur J Radiol · 2025-03-15

本研究回顾性分析42例头颈部鳞状细胞癌患者的术前MRI与淋巴结清扫病理,由两名放射科医师独立采用Node-RADS评分(4分和5分视为阳性)并与术后组织病理对照。在评估的118枚淋巴结中,Node-RADS诊断转移性淋巴结的敏感度为61.54%、特异度为89.69%、总体准确率为87.29%。作者认为Node-RADS具有高特异度和准确率,是有望标准化术前影像评估的工具,但需进一步研究验证。

要点

  • Node-RADS以4分和5分为阳性时,诊断转移性淋巴结的敏感度为61.54%、特异度为89.69%、总体准确率为87.29%。
  • 淋巴结坏死、边缘不规则和形状与组织病理结果显著相关(p < 0.0001)。
  • 118枚淋巴结中26枚(22.03%)为转移(N+),8枚(7.78%)为ENE+。

核心结论

  • Node-RADS在识别头颈部鳞状细胞癌转移性淋巴结方面表现出高特异度和准确率,是有望标准化术前影像评估的工具,但需进一步研究验证其应用并改进与先进影像技术的整合以提高诊断精度。

研究设计与样本

  • 回顾性分析42例接受术前MRI和淋巴结清扫的头颈部鳞状细胞癌患者,两名放射科医师独立采用Node-RADS系统评估MRI,并与术后组织病理学结果对照。

关键影像表现/征象

  • 评估的118枚淋巴结中26枚(22.03%)为转移(N+),8枚(7.78%)为ENE+。
  • 淋巴结坏死、边缘不规则和形状与组织病理学结果显著相关(p < 0.0001)。
  • 不规则/边界不清的边缘也用于评估EN+的检测。

诊断标准与关键数值

  • Node-RADS评分4分和5分视为阳性。
  • Node-RADS诊断转移性淋巴结的敏感度为61.54%、特异度为89.69%、PPV为76.19%、NPV为89.69%、总体准确率为87.29%。

临床应用与阅片要点

  • 作者认为Node-RADS是有望标准化术前影像评估的工具,但需进一步研究验证其应用。

局限性

  • 原文结论指出需进一步研究验证其应用并改进与先进影像技术的整合以提高诊断精度。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: This study aimed to assess the accuracy of the Node-RADS scoring system in assessing metastatic lymph node (LN) involvement in patients with head and neck squamous cell carcinoma (HNSCC), a critical factor for treatment planning and prognosis.

MATERIALS AND METHODS: A retrospective analysis was conducted on 42 HNSCC patients who underwent preoperative MRI and lymph node dissection. Two radiologists independently evaluated the MRI scans using the Node-RADS system, and the results were compared with postoperative histopathological findings. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and overall accuracy of Node-RADS were calculated, considering LNs with Node-RADS scores of 4 and 5 as positive. LN features such as size, texture, necrosis, border irregularity, and shape were analyzed for their correlation with metastatic involvement. Irregular/ill-defined borders were also evaluated for the detection of Extranodal extension (ENE+).

RESULTS: Out of 118 LNs assessed, 26 (22.03 %) were metastatic (N+), and 8 (7.78 %) were ENE+. Node-RADS demonstrated a sensitivity of 61.54 %, specificity of 89.69 %, PPV of 76.19 %, NPV of 89.69 %, and an overall accuracy of 87.29 %. Significant correlations were observed between LN characteristics like necrosis, border irregularity, shape, and histopathological results (p < 0.0001).

CONCLUSION: The Node-RADS system exhibited high specificity and accuracy in identifying metastatic LNs in HNSCC patients, making it a promising tool for standardizing preoperative imaging assessments. However, further studies are needed to validate its application and improve its integration with advanced imaging techniques for enhanced diagnostic precision.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Lorusso G, Villanova I, Greco S, et al. Accuracy of MRI-based Node-RADS in predicting metastatic lymph node involvement in Head and Neck Squamous Cell Carcinoma. Eur J Radiol. 2025. PMID: 40117957. doi:10.1016/j.ejrad.2025.112051

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。