文献速递神经头颈CTDR

X线摄影、X线断层融合与CT对眶内金属异物筛查的比较

A Comparison of Radiography, X-Ray Tomosynthesis, and CT for Intraorbital Metallic Foreign Body Screening.
PubMed 文献 · J Am Coll Radiol · 2025-01-01

本研究用半仿体模型比较数字X线摄影(DR)、数字断层融合(DT)和CT检测眶内金属异物的效能。CT的ROC曲线下面积(AUC)为0.90,优于DT的0.79和DR的0.78(P < .05),差异主要来自钢质碎片;0.8 mg及以下的钢碎片DT和DR均未检出,而CT可检出最小0.4 mg的钢碎片。

要点

  • CT检测眶内金属异物的AUC为0.90,优于DT的0.79和DR的0.78(P < .05)。
  • 钢碎片0.8 mg及以下时DT和DR未检出,CT可检出最小0.4 mg的钢碎片。
  • CT与DT、DR的效能差异主要归因于钢质碎片的检出差异。

核心结论

  • 在半仿体模型中,CT检测眶内金属异物的效能优于DT和DR,差异主要来自钢质碎片的检出;由于钢常具有铁磁性,这一区别对MRI前眶部筛查的成像方式选择有意义。

研究设计与样本

  • 体外半仿体研究:制作铝、钢和钴粘结碳化钨碎片,嵌入置于人颅骨模型双侧眼眶的葡萄中,并浸于水浴形成半仿体;采集DR、DT和CT图像,由6名有经验的放射科医师阅片并对检出眶内金属异物的信心评分;采用ROC分析和多阅片者多病例方差分析比较各成像方式。

关键影像表现/征象

  • 钢碎片质量0.8 mg及以下时,DT和DR均未检出,CT可检出最小0.4 mg的钢碎片。

诊断标准与关键数值

  • CT、DT、DR检测眶内金属异物的AUC分别为0.90、0.79、0.78;两两比较显示CT优于DT和DR(P < .05)。
  • 按金属类型分层后,仅钢碎片在各成像方式间观察到显著的检出效能差异。

临床应用与阅片要点

  • 由于钢常具有铁磁性,CT与DT/DR在钢碎片检出上的差异对MRI前眶部筛查的成像方式选择有意义。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: Before MRI examination, patients are often screened for intraorbital metallic foreign bodies (IMFBs) via questioning, clinical record review, and imaging when appropriate. This work compares the screening performance of digital radiography (DR), digital tomosynthesis (DT), and CT in detecting IMFBs composed of various metals and identifies their limits of detection.

METHODS: Fragments of aluminum, steel, and cobalt-cemented tungsten carbide were produced. A human skull model, with metal fragments embedded in grapes placed in each orbit, was submerged in a water bath to create a semi-anthropomorphic phantom. Phantom orbit images were acquired with DR, DT, and CT. Six experienced radiologists reviewed images and scored their confidence in detecting IMFBs. Receiver operating characteristic analysis was performed and a multireader, multicase analysis of variance was used to compare the modalities.

RESULTS: Performance comparison across modalities yielded area under the receiver operating characteristic curve values of 0.90, 0.79, and 0.78 for CT, DT, and DR, respectively. Pairwise comparison revealed that CT was superior to both DT and DR (P < .05). When stratified by metal type, a significant performance difference among modalities was only observed for steel. Steel fragments of mass 0.8 mg and smaller were not detected using DT or DR, but even the smallest steel fragments of 0.4 mg were detectable with CT.

CONCLUSION: CT outperformed DT and DR in detecting IMFBs using a semi-anthropomorphic phantom. This performance difference is largely attributed to differences in detection of steel fragments. Since steel is often ferromagnetic, this distinction is relevant for imaging modality selection for orbit screening before MRI.

来源:J Am Coll Radiol,查看原文。版权归原作者所有。

引用

  1. Brunnquell CL, Vasconcelos AG, Hoff MN, et al. A Comparison of Radiography, X-Ray Tomosynthesis, and CT for Intraorbital Metallic Foreign Body Screening. J Am Coll Radiol. 2025. PMID: 40044318. doi:10.1016/j.jacr.2024.12.002

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。