ANAIS研究临床结果:急性缺血性卒中患者使用ANA装置联合支架取栓器进行机械取栓
ANAIS研究是一项前瞻性单臂多中心研究,评估ANA漏斗导管联合支架取栓器在急性缺血性卒中患者中的性能。主要终点为3次取栓内无补救治疗下成功再灌注(eTICI 2b50-3),意向治疗(ITT)人群达70%(30/43),符合方案(PP)人群达81%(26/32)。24小时症状性颅内出血和严重器械不良事件均为0/43。漏斗部署于ICA C1段时主要终点低于C2/C3段和C4及以上段,持续抽吸时主要终点高于仅末端抽吸。
要点
- 主要终点3次内无补救成功再灌注ITT 70%、PP 81%,首过eTICI 2c-3为ITT 44%、PP 56%。
- 漏斗部署于C1段时主要终点(ITT 36%、PP 57%)低于C2/C3段(ITT 89%、PP 100%)及C4以上段(ITT 71%、PP 77%)。
- 从取栓操作开始持续抽吸时主要终点(ITT 81%、PP 92%)高于仅末端抽吸(ITT 36%、PP 50%)。
核心结论
- ANA漏斗导管联合支架取栓器获得高再灌注率和首过成功率,安全性良好;漏斗部署于ICA C1段以上且取栓时持续抽吸时成功再灌注更优。
研究设计与样本
- 前瞻性、单臂、多中心研究,3个中心共治疗43例前循环卒中行机械取栓患者,由独立影像核心实验室盲法评估结局。
诊断标准与关键数值
- 主要终点为3次取栓内无补救治疗下成功再灌注(expanded TICI 2b50-3),ITT人群70%(30/43),PP人群81%(26/32);首过expanded TICI 2c-3率ITT 44%(19/43),PP 56%(18/32);安全性终点为症状性颅内出血和严重器械不良事件,24小时均为0/43。
临床应用与阅片要点
- 作者结论提示漏斗部署于ICA C1段以上(C2/C3或C4及以上)时成功再灌注优于C1段,且从取栓操作开始持续抽吸优于仅末端抽吸。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND AND PURPOSE: The ANA thrombectomy system is a funnel catheter comprising a self-expanding coated funnel that works in conjunction with a standard stent retriever and is designed to locally restrict flow and reduce clot fragmentation. The ANAIS Study to Confirm the Safety and Performance of the ANA 5F Advanced Neurovascular Access investigated the performance of the ANA funnel catheter in patients with stroke.
MATERIALS AND METHODS: Mechanical thrombectomy using the ANA device in combination with a stent retriever in subjects with acute ischemic stroke. This is a prospective, single-arm, multicenter study with blinded outcome assessment by an independent imaging Core Lab. Patients with anterior circulation stroke undergoing mechanical thrombectomy were eligible. The primary end point was successful reperfusion (expanded TICI 2b50-3) within 3 passes without rescue therapy. The safety end point combined symptomatic intracranial hemorrhage and severe adverse device effect.
RESULTS: Forty-three subjects were treated in 3 centers: mean age, 70.5 (SD, 13.1) years, 44.2% (19/43) women; median admission NIHSS score, 16.0 (range, 12.5-19.5). The primary end point was achieved in 70% (30/43) and 81% (26/32) in the intention-to-treat (ITT) and per-protocol (PP) populations, respectively. The rates of first pass expanded TICI 2c-3 were 44% (19/43) and 56% (18/32) in the ITT and PP populations, respectively. There were no severe adverse device effects/symptomatic ICH at 24 hours (0/43). When the funnel was deployed in the C1 segment of the internal carotid artery (Bouthillier Classification), the primary end point (ITT, 36%; PP, 57%) was lower than when deployed in the C2/C3 segments (ITT, 89%; PP, 100%; P < .01), or in the C4 or above segments (ITT, 71%; PP, 77%; P < .05). The primary end point was higher when continuous aspiration was applied from initiation of the retrieval maneuver (ITT, 81%; PP, 92%) compared with end-aspiration only (ITT, 36%; PP, 50%, P < .01).
CONCLUSIONS: The ANA funnel catheter achieved high rates of reperfusion and first pass success, with a good safety profile. Successful reperfusion was superior when the funnel was deployed above the C1 segment of the ICA and clot retrieval was performed under continuous aspiration.
引用
- Tomasello A, Zamarro J, Terceño M, et al. Clinical Results of the ANAIS Study: Mechanical Thrombectomy Using the ANA Device in Combination with a Stent Retriever in Subjects with Acute Ischemic Stroke. AJNR Am J Neuroradiol. 2025. PMID: 40037699. doi:10.3174/ajnr.A8556
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。