机器学习影像组学预测胶质瘤H3K27M突变:系统综述与Meta分析
本系统综述与Meta分析共纳入15项研究,评估机器学习模型基于MRI影像组学预测胶质瘤H3K27M突变的诊断性能。汇总AUC为0.87(95%CI 0.77-0.97),敏感度92%(95%CI 83%-96%),特异度89%(95%CI 86%-91%)。深度学习模型敏感度不优于机器学习(P=0.6),但机器学习模型汇总特异度显著更高(P<0.01)。
要点
- 机器学习MRI影像组学模型预测胶质瘤H3K27M突变汇总AUC为0.87(95%CI 0.77-0.97)。
- 汇总敏感度92%(95%CI 83%-96%),汇总特异度89%(95%CI 86%-91%)。
- 深度学习模型敏感度不优于机器学习(P=0.6),机器学习汇总特异度显著更高(P<0.01)。
核心结论
- 机器学习MRI影像组学模型在预测胶质瘤H3K27M突变方面具有较好的诊断性能。
研究设计与样本
- 系统综述与Meta分析,于2024年9月16日检索PubMed、Embase、Scopus和Web of Science,最终纳入15项研究,使用R软件进行Meta分析、敏感性分析和Meta回归。
诊断标准与关键数值
- 汇总AUC为0.87(95%CI 0.77-0.97),汇总敏感度92%(95%CI 83%-96%),汇总特异度89%(95%CI 86%-91%)。
- 诊断比值比为78.1(95%CI 33.3-183.5)。
- SROC曲线AUC为0.921,估计敏感度为0.898,假阳性率为0.126。
临床应用与阅片要点
- 作者认为基于机器学习的MRI影像组学模型在预测胶质瘤H3K27M突变方面具有较好的诊断性能。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: Noninvasive prediction and identification of the H3K27M mutation play an important role in optimizing therapeutic strategies and improving outcomes in gliomas. In this systematic review and meta-analysis, we aimed to evaluate the performance of machine learning (ML)-based models in predicting H3K27M mutation in gliomas.
METHODS: Literature records were retrieved on September 16th, 2024, in PubMed, Embase, Scopus, and Web of Science. Records were screened according to the eligibility criteria, and the data from the included studies were extracted. The meta-analysis, sensitivity analysis, and meta-regression were conducted using R software.
RESULTS: A total of 15 studies were included in our study. Our meta-analysis demonstrated a pooled AUC, sensitivity, and specificity of 0.87 (95% CI: 0.77-0.97), 92% (95% CI: 83%-96%), and 89% (95% CI: 86%-91%)), respectively. The subgroup meta-analysis revealed that despite the higher sensitivity of the deep learning (DL) models, the sensitivity is not superior to ML (P = 0.6). In contrast, the ML-based pooled specificity was significantly higher (P < 0.01). The meta-analysis revealed a 78.1 (95% CI: 33.3 - 183.5). The SROC curve indicated an AUC of 0.921, and the estimated sensitivity is 0.898 concurrent with the false positive rate of 0.126, which indicates high sensitivity with a low false positive rate.
CONCLUSION: Our systematic review and meta-analysis demonstrated that ML-based magnetic resonance imaging (MRI) radiomics models are associated with promising diagnostic performance in predicting H3K27M mutation in gliomas.
引用
- Hajikarimloo B, Tos SM, Kooshki A, et al. Machine learning radiomics for H3K27M mutation prediction in gliomas: A systematic review and meta-analysis. Neuroradiology. 2025. PMID: 40163098. doi:10.1007/s00234-025-03597-y
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。