超声辅助开放血脑屏障的吲哚菁绿光声与荧光成像监测
研究采用BALB/c小鼠模型,在聚焦超声联合微泡开放血脑屏障后,以吲哚菁绿作为双模态造影剂进行光声与荧光成像,评估屏障开放与关闭动态;光声成像在聚焦超声后1小时内监测可靠,荧光成像在24小时检测外渗更有效,荧光强度与钆增强MRI强相关,血脑屏障关闭呈指数衰减模型、半关闭时间约81分钟,开放程度与微泡剂量成正比。
要点
- 光声成像在聚焦超声后1小时内可可靠监测血脑屏障开放。
- 荧光成像在24小时检测吲哚菁绿外渗更有效。
- 荧光强度与钆增强MRI强相关,血脑屏障半关闭时间约81分钟。
核心结论
- 基于吲哚菁绿的光声与荧光成像为监测聚焦超声诱导的血脑屏障开放提供了非侵入、成本效益好的MRI替代方案,两种技术提供互补的时间窗口,提高血脑屏障通透性评估精度。
研究设计与样本
- BALB/c小鼠接受不同剂量微泡的聚焦超声介导血脑屏障开放并给予吲哚菁绿,于聚焦超声后不同时间点行光声与荧光成像,以钆增强MRI作为血脑屏障通透性评估的金标准,分析微泡剂量与注射时机对血脑屏障关闭动力学的影响。
关键影像表现/征象
- 光声成像在聚焦超声后第一个小时内提供可靠的血脑屏障监测。
- 荧光成像在24小时检测吲哚菁绿外渗更有效。
- 荧光强度与MRI对比增强之间观察到强相关。
- 血脑屏障关闭遵循指数衰减模型,半关闭时间约81分钟。
- 血脑屏障开放程度与给予的微泡剂量成正比。
诊断标准与关键数值
- 以钆增强MRI作为血脑屏障通透性评估的金标准。
- 荧光强度与MRI对比增强强相关。
- 血脑屏障关闭呈指数衰减模型,半关闭时间约81分钟。
临床应用与阅片要点
- 光声成像适用于聚焦超声后1小时内评估血脑屏障开放。
- 荧光成像适用于24小时检测吲哚菁绿外渗。
- 血脑屏障开放程度与微泡剂量成正比,半关闭时间约81分钟可用于判断关闭时程。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: The blood-brain barrier (BBB) is a selectively permeable membrane that restricts drug delivery to the central nervous system. Focused ultrasound (FUS) combined with microbubbles (MBs) is a promising technique to transiently open the BBB, enabling therapeutic delivery. However, real-time monitoring of BBB permeability changes remains challenging. This study investigated the use of indocyanine green (ICG) as a bi-modal contrast agent for photoacoustic and fluorescence imaging to assess BBB opening and closure dynamics.
METHODS: BALB/c mice underwent FUS-mediated BBB opening with different doses of MBs and ICG administration. Photoacoustic and fluorescence imaging were performed at various time points post-FUS to evaluate ICG extravasation dynamics. Magnetic resonance imaging (MRI) with gadolinium contrast was used as the gold standard for BBB permeability assessment. The effect of MB dose and injection timing on BBB closure kinetics was analyzed.
RESULTS: Photoacoustic imaging provided reliable BBB monitoring within the first hour post-FUS, whereas fluorescence imaging was more effective at detecting ICG extravasation at 24 h. A strong correlation was observed between fluorescence intensity and MRI-based contrast enhancement, confirming BBB opening dynamics. BBB closure followed an exponential decay model, with a half-closure time of approximately 81 min. The degree of BBB opening was proportional to the MB dose administered.
CONCLUSION: ICG-based photoacoustic and fluorescence imaging provide a non-invasive and cost-effective alternative to MRI for monitoring FUS-induced BBB opening. These techniques offer complementary temporal windows for assessment, improving the precision of BBB permeability evaluation in preclinical and potentially clinical applications.
引用
- Ador T, Fournié M, Rigollet S, et al. Ultrasound-Assisted Blood-Brain Barrier Opening Monitoring by Photoacoustic and Fluorescence Imaging Using Indocyanine Green. Ultrasound Med Biol. 2025. PMID: 40155229. doi:10.1016/j.ultrasmedbio.2025.02.016
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。