文献速递儿科影像泌尿生殖技术与安全CT

分团注射对比剂联合双能CT扫描技术在儿童CT尿路成像中的应用价值

Application value of split-bolus contrast injection combined with dual-energy CT scanning technology in pediatric CTU imaging.
PubMed 文献 · Eur J Radiol · 2025-01-24

前瞻性纳入128例0-17岁儿童随机分三组:A组为高螺距单团注四期扫描,B组为双能分团注射(50%+50%,间隔37-43秒)两期扫描,C组为双能分团注射(65%+35%,间隔37-43秒)两期扫描,B、C组由皮质髓质期经碘减影获得虚拟平扫图像。结果显示分团注射联合双能CT可提升儿童CTU图像质量并降低辐射剂量。

要点

  • B组和C组虚拟平扫图像评分低于A组真实平扫,差异无统计学意义(P>0.05)。
  • 皮质期图像主观评价B组优于C组、C组优于A组(P<0.05)。
  • 辐射剂量B组低于C组、C组低于A组(P<0.05),BMI与有效辐射剂量相关(r=0.62,P<0.01)。

核心结论

  • 分团注射对比剂联合双能CT可提升儿童CTU图像质量并降低辐射剂量。

研究设计与样本

  • 前瞻性随机对照研究,纳入128例0-17岁儿童,随机分为A、B、C三组;A组采用高螺距单团注四期扫描,B组双能分团注射(50%+50%,间隔37-43秒)两期扫描,C组双能分团注射(65%+35%,间隔37-43秒)两期扫描,B、C组由皮质髓质期经碘减影获得虚拟平扫图像。

诊断标准与关键数值

  • A组皮质期与B、C组皮质髓质期的肾皮质、竖脊肌CT值及SD值排序为B组>C组>A组(P<0.05)。
  • A组皮质期与B、C组皮质髓质期(皮质)的皮质CNR和SNR排序为C组>B组>A组(P<0.05)。
  • A组髓质期与B、C组皮质髓质期(髓质)的髓质CNR和SNR排序为A组>C组>B组(P<0.05)。
  • B、C组虚拟平扫图像评分低于A组真实平扫图像(P>0.05)。
  • 皮质髓质期和排泄期图像主观评价排序为B组>C组>A组(P<0.05)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To explore the clinical value of combining split-bolus contrast injection with dual-energy CT(DECT) scanning technology in pediatric computed tomography urography (CTU) imaging.

METHODS: A total of 128 children aged 0-17 years were prospectively selected and randomly assigned to three groups: A, B, and C. For Group A, a high-pitch flash mode was employed, where a single bolus of contrast agent was followed by four-phase scanning (noncontrast, cortex, medulla, and excretory phases). In Group B, a dual-energy scanning mode was used with a split-bolus injection technique (50 % of the contrast agent was administered initially, followed by the remaining 50 % after 37-43 s), and the children underwent two-phase scanning (corticomedullary and excretory phases). In Group C, dual-energy scanning was similarly used with a split-bolus injection technique (65 % contrast agent was administered initially, followed by the remaining 35 % after 37-43 s), along with two-phase scanning (corticomedullary and excretory phases). Virtual noncontrast (VNC) images were obtained from the corticomedullary phase images using iodine subtraction techniques for Groups B and C. The image quality and radiation dose across the groups were compared and analysed.

RESULTS: When the CT values of the renal cortex, erector spinae muscles, and standard deviation (SD) values were compared between Group A's cortical phase and Groups B and C's corticomedullary phases, the order was Group B > Group C > Group A (P < 0.05). The comparison of the cortical CNR and SNR between Group A's cortical phase and Groups B's and C's corticomedullary phases (cortices) revealed that Group C > Group B > Group A (P < 0.05). The comparison of the medullary CNR and SNR between Group A's medullary phase and Groups B and C's corticomedullary phases (medulla) showed that Group A > Group C > Group B (P < 0.05). The scores for the VNC images in Groups B and C were lower than those for the true noncontrast (TNC) images in Group A (P > 0.05). In the subjective evaluations of the corticomedullary and excretory phase images, Group B > Group C > Group A (P < 0.05). The comparison of radiation doses revealed that Group B < Group C < Group A (P < 0.05). A significant correlation was found between BMI and the effective radiation dose (P < 0.01), with a correlation coefficient of 0.62.

CONCLUSION: The combination of split-bolus contrast injection and DECT enhances image quality in pediatric CTU while reducing radiation dosage.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Chen H, Deng Z, Tan T, et al. Application value of split-bolus contrast injection combined with dual-energy CT scanning technology in pediatric CTU imaging. Eur J Radiol. 2025. PMID: 39874617. doi:10.1016/j.ejrad.2025.111949

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。