文献速递骨肌技术与安全MR

用于全身MRI中稳健骨髓分割的先进自动化模型

Advanced Automated Model for Robust Bone Marrow Segmentation in Whole-body MRI.
PubMed 文献 · Acad Radiol · 2025-01-22

本研究基于8个中心、多厂商多协议的210例单克隆浆细胞疾病患者全身MRI数据,建立nnU-Net骨髓分割模型(先进分割模型),在测试集I和II上平均Dice评分分别为0.89±0.13和0.88±0.11,显著高于既往基础模型(p<0.05),对骨髓瘤相关病变、伪影或低图像质量病例也能精确分割。

要点

  • 先进模型在测试集I平均Dice为0.89±0.13、测试集II为0.88±0.11,均显著高于基础模型(p<0.05)。
  • 单骨骨髓空间Dice在测试集I为0.77–0.96、测试集II为0.81–0.95。
  • 骨髓瘤相关病变、伪影或低图像质量骨髓仍可被精确分割。

核心结论

  • 先进模型在多中心异质采集的全身MRI上,即使存在严重病变,也能实现可靠的自动化骨髓分割。

研究设计与样本

  • 研究纳入8个中心、多厂商、多协议、不同场强的207例单克隆浆细胞疾病患者共210例全身MRI;训练集为来自中心1的186例T1加权全身MRI,测试集I为中心2的12例,测试集II为中心3–8的9例。

关键影像表现/征象

  • 先进模型对脊柱、骨盆、肱骨和股骨各骨髓空间进行分割,测试集I单骨Dice为0.77–0.96,测试集II为0.81–0.95。
  • 骨髓受骨髓瘤相关病变、伪影或低图像质量影响时,先进模型仍能精确分割。
  • 文中包含示例病例,展示在肿瘤负荷广泛的T1加权全身MRI上的分割性能。

诊断标准与关键数值

  • 先进模型在测试集I的平均Dice评分为0.89±0.13,测试集II为0.88±0.11。
  • 先进模型Dice评分显著高于既往基础模型(p<0.05),比较采用Wilcoxon符号秩检验。

临床应用与阅片要点

  • 先进模型可用于多中心异质采集的全身MRI,对骨髓瘤相关病变、伪影或低图像质量病例仍能可靠分割,有助于阅片时骨髓评估。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: To establish an advanced automated bone marrow (BM) segmentation model on whole-body (WB-)MRI in monoclonal plasma cell disorders (MPCD), and to demonstrate its robust performance on multicenter datasets with severe myeloma-related pathologies.

MATERIALS AND METHODS: The study cohort comprised multi-vendor, multi-protocol imaging data acquired with varying field strength across 8 different centers. In total, 210 WB-MRIs of 207 MPCD patients were included. An nnU-Net algorithm was established for segmenting the individual bone marrow spaces (BMS) of the spine, pelvis, humeri and femora (advanced segmentation model). For this task, 186 T1-weighted (T1w) WB-MRIs from center 1 were used in the training set. Test sets included 12 T1w WB-MRIs from center 2 (I) and 9 T1w WB-MRIs from centers 3-8 (II). Example cases were included to showcase segmentation performance on T1w WB-MRIs with extensive tumor load. The segmentation accuracy of the advanced segmentation model was compared to a prior established basic segmentation model by calculating Dice scores and using the Wilcoxon signed-rank test.

RESULTS: The mean Dice score on the individual BMS was 0.89±0.13 (test set I) and 0.88±0.11 (test set II), significantly higher than the Dice scores of a prior basic model (p<0.05). Dice scores for the BMS of the individual bones ranged from 0.77 to 0.96 (test set I), and 0.81 to 0.95 (test set II). BM altered by myeloma-relevant pathologies, artifacts or low imaging quality was precisely segmented.

CONCLUSION: The advanced model performed reliable, automated segmentations, even on heterogeneously acquired multicenter WB-MRIs with severe pathologies.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Bauer F, Kächele J, Bernhard J, et al. Advanced Automated Model for Robust Bone Marrow Segmentation in Whole-body MRI. Acad Radiol. 2025. PMID: 39848889. doi:10.1016/j.acra.2024.12.060

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。