指南与共识神经骨肌技术与安全CTDR

基于循证的影像转诊指南能否促进合理影像检查:它们都相同吗?

Using evidence-based imaging referral guidelines to facilitate appropriate imaging: Are they all the same?
指南 / 共识 · Eur J Radiol · 2025-01-18

本研究回顾性分析2022年10月1日至12月31日急诊科452例颈椎X线摄影和153例颈椎CT转诊,比较ACR、ESR、RCR三部影像转诊指南的适当性。颈椎X线适当率依指南不同为13.3%–75.2%,颈椎CT适当率为90.8%且三部指南一致;X线指南间一致性轻微(κ=0.135),CT指南间几乎完全一致(κ=1.000)。

要点

  • 颈椎X线转诊适当率依所用指南不同差异大(13.3%–75.2%),审核结果受指南选择影响。
  • 颈椎CT转诊适当率90.8%,三部指南评定完全一致(κ=1.000)。
  • ACR AC与ESR iGuide对X线评定中度一致(κ=0.765),RCR iRefer与两者均无一致性。

核心结论

  • 三部指南对颈椎X线评定仅轻微一致,使审核过程复杂化并影响审核输出。
  • 多学科参与对颈椎CT适当率有正向影响。
  • 需协调并优先制定常见临床场景的指南。

研究设计与样本

  • 回顾性分析电子病历,时间范围为2022年10月1日至12月31日。
  • 共评估452例X线摄影和153例CT影像转诊。
  • 每例将初始临床诊断与相应临床记录整合分析。
  • 适当性评级二分为「有指征」或「无指征」。
  • 采用Fleiss Kappa和Cohen Kappa计算指南间评定者一致性。

诊断标准与关键数值

  • 颈椎X线转诊总体适当率依所用指南不同为13.3%–75.2%。
  • 颈椎CT转诊适当率为90.8%,三部指南评定结果相同。
  • 颈椎X线指南间Fleiss Kappa为0.135(95%CI 0.088–0.183,p<0.001),一致性轻微。
  • 颈椎CT指南间Fleiss Kappa为1.000(95%CI 0.909–1.091,p<0.001),几乎完全一致。
  • X线 pairwise:ACR AC与ESR iGuide中度一致(κ=0.765,p<0.001),RCR iRefer与两者均无一致性水平。

临床应用与阅片要点

  • 原文指出多学科参与对颈椎CT适当率有正向影响。
  • 原文认为指南间一致性差异使审核过程复杂化并影响审核输出。
  • 原文提出需协调并优先制定常见临床场景的指南。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: Countries worldwide have selected, adopted, adapted, and translated evidence-based imaging referral guidelines from radiology professional bodies. This study establishes the concordance of three imaging referral guidelines from the ACR, ESR, and RCR, and examines the emergency department cervical spine imaging appropriateness rates.

MATERIALS AND METHODS: A retrospective analysis of the electronic medical records was performed between October 1st to December 31st, 2022, evaluating 452 radiography and 153 CT imaging referrals. For each case, the initial clinical diagnosis was integrated with the corresponding clinical notes for analysis. Evaluation of the appropriateness rating was dichotomised to either 'indicated' or 'not indicated' for analytical and practical purposes. The inter-rater agreement for the imaging referral guidelines was calculated using Fleiss' Kappa and Cohen's Kappa.

RESULTS: The overall appropriateness rate of X-ray cervical spine imaging referrals was 13.3 % -75.2 %, depending on the imaging referral guidelines utilised. The appropriateness rate of CT cervical spine was 90.8 %, which was an identical rate for all three of the guidelines. Fleiss' Kappa indicated the guidelines for X-ray of the cervical spine had slight agreement (κ = 0.135 (95 % CI, 0.088 to 0.183), p < 0.001) and almost perfect agreement amongst guidelines for CT cervical spine (κ = 1.000 (95 % CI, 0.909 to 1.091), p < 0.001). For pairwise comparison, ACR AC and ESR iGuide for X-ray demonstrated moderate agreement (κ = 0.765, p < 0.001); however, RCR iRefer had no level of agreement with both. For CT, there was almost perfect agreement between all the guidelines.

CONCLUSION: The guidelines demonstrated slight agreement for X-ray cervical spine and almost perfect agreement for CT cervical spine, complicating audit process and influencing audit output. Multidisciplinary buy-in positively impacts CT cervical spine appropriateness rates. Harmonising and prioritising guideline development for commonly encountered clinical scenarios is required.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Tay YX, Foley SJ, Ong ME, et al. Using evidence-based imaging referral guidelines to facilitate appropriate imaging: Are they all the same? Eur J Radiol. 2025. PMID: 39864244. doi:10.1016/j.ejrad.2025.111933

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。