文献速递乳腺MR

基于多参数磁共振成像的列线图提高BI-RADS 4类乳腺病变诊断效能:与Kaiser评分的比较研究

A nomogram based on multiparametric magnetic resonance imaging improves the diagnostic performance of breast lesions diagnosed as BI-RADS category 4: A comparative study with the Kaiser score.
PubMed 文献 · Eur J Radiol · 2025-01-03

回顾性纳入168例超声和/或乳腺X线诊断为BI-RADS 4类的乳腺病变患者,随机按7:3分为训练集117例和验证集51例。构建结合Kaiser评分、合成MRI参数、ADC和临床特征的列线图,其训练集和验证集AUC分别为0.968和0.959,高于Kaiser评分、ADC、T2和年龄。

要点

  • 列线图在训练集和验证集AUC分别为0.968和0.959,高于Kaiser评分等单独指标。
  • 年龄较大、Kaiser评分较高、ADC较低和T2弛豫时间较低是乳腺恶性的独立预测因素。
  • Kaiser评分、ADC和T2的AUC之间无显著差异。

核心结论

  • 尽管Kaiser评分、ADC和T2的AUC之间无显著差异,构建的列线图结合这些参数可显著提高区分BI-RADS 4类乳腺病变良恶性的诊断效能。

研究设计与样本

  • 回顾性队列研究,纳入2022年12月至2024年2月168例超声和/或乳腺X线诊断为BI-RADS 4类的乳腺病变患者,随机按7:3分为训练集117例和验证集51例,以组织病理学为参考标准;由两名经验丰富的放射科医师独立评估Kaiser评分并测量ADC和合成MRI参数定量值。

诊断标准与关键数值

  • 列线图预测乳腺恶性的AUC在训练集为0.968(95%CI 0.934-0.996),在验证集为0.959(95%CI 0.863-0.995)。

临床应用与阅片要点

  • 列线图纳入年龄、Kaiser评分、ADC和T2弛豫时间,可用于辅助区分BI-RADS 4类乳腺病变的良恶性。

局限性

  • 未来需要在实际应用中进行外部验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To construct a nomogram combining Kaiser score (KS), synthetic MRI (syMRI) parameters, apparent diffusion coefficient (ADC), and clinical features to distinguish benign and malignant breast lesions better.

METHODS: From December 2022 to February 2024, a retrospective cohort of 168 patients with breast lesions diagnosed as Breast Imaging Reporting and Data System (BI-RADS) category 4 by ultrasound and/or mammography was included. The research population was divided into the training set (n = 117) and the validation set (n = 51) by random sampling with a ratio of 7:3. Breast lesions' KS, ADC, relaxation time of syMRI, and clinical and imaging features were statistically analyzed and compared between malignant and benign groups. Two experienced radiologists independently assigned KS, and measured quantitative values of ADC and parameters of syMRI, and the intraclass correlation coefficient (ICC) was calculated. Independent predictors were identified by univariable and multivariable logistic regression analysis. Then, a nomogram was established, and its performance was evaluated by the area under the curve (AUC), calibration curve, and decision curve.

RESULTS: There were 168 lesions (118 malignant and 50 benign) in 168 female patients confirmed by histopathology. The interobserver agreement for each quantitative parameter was excellent. Older patient (OR = 1.091, 95 % confidence interval [CI]: 1.017-1.170, P = 0.014), higher lesions' KS (OR = 288.431, 95 % CI: 34.930-2381.654, P < 0.001), lower ADC (OR = 0.077, 95 % CI: 0.011-0.558, P = 0.011), and lower T2 relaxation time (OR = 0.918, 95 % CI: 0.868-0.972, P = 0.003) were independent predictors of breast malignancies and utilized to establish the nomogram. The accuracy of KS, ADC, T2, and patient age in predicting malignant breast lesions was 88.89 %, 79.48 %, 82.05 %, and 58.97 %, respectively. No significant differences in AUCs of KS, ADC and T2 were observed in distinguishing benign from malignant breast lesions. The nomogram yielded higher AUCs of 0.968 (0.934-0.996) and 0.959 (0.863-0.995) in training and validation sets than KS, ADC, T2, and patient age (p < 0.05).

CONCLUSION: Although there were no significant differences among the AUCs of KS, ADC, and T2, the constructed nomogram incorporating these parameters significantly improves diagnostic performance for distinguishing benign and malignant BI-RADS 4 breast lesions. Future external validation is needed in practical applications.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Yang X, Lu Z, Tan X, et al. A nomogram based on multiparametric magnetic resonance imaging improves the diagnostic performance of breast lesions diagnosed as BI-RADS category 4: A comparative study with the Kaiser score. Eur J Radiol. 2025. PMID: 39793481. doi:10.1016/j.ejrad.2025.111920

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。