超声造影特征与肉芽肿性乳腺炎复发风险的相关性分析及预测模型构建
回顾性纳入2017至2022年510例肉芽肿性乳腺炎患者,分为未复发组389例和复发组121例,分析超声造影特征与复发风险的相关性并构建XGBoost预测模型。均匀等增强、不均匀等增强、灌注缺损及灌注缺损边缘不光滑与复发风险相关,模型AUC为0.822,外部验证AUC为0.808。
要点
- 超声造影显示均匀等增强、不均匀等增强、灌注缺损及灌注缺损边缘不光滑与肉芽肿性乳腺炎复发风险相关。
- 整合超声造影特征的XGBoost预测模型AUC为0.822,外部验证AUC为0.808。
- 灌注缺损边缘不光滑与复发风险的相关系数最高(rho=0.234,P<0.001)。
核心结论
- 超声造影可显示与肉芽肿性乳腺炎复发风险相关的特定血管和增强模式,具有诊断和预后价值;整合超声造影特征的预测模型AUC为0.822,外部验证AUC为0.808。
研究设计与样本
- 回顾性研究,纳入2017至2022年510例肉芽肿性乳腺炎患者,未复发组389例、复发组121例,采用超声造影评估病灶灌注和增强模式,使用XGBoost构建预测模型并进行外部验证。
关键影像表现/征象
- 均匀等增强与复发风险相关(rho=0.137,P=0.002)。
- 不均匀等增强与复发风险相关(rho=0.134,P=0.002)。
- 灌注缺损与复发风险相关(rho=0.127,P=0.004)。
- 灌注缺损边缘不光滑与复发风险相关(rho=0.234,P<0.001)。
诊断标准与关键数值
- 整合超声造影模式的预测模型AUC为0.822。
- 外部验证确认模型效能,AUC为0.808。
临床应用与阅片要点
- 阅片时可关注超声造影中的均匀等增强、不均匀等增强、灌注缺损及灌注缺损边缘不光滑等特征,这些特征与肉芽肿性乳腺炎复发风险相关。
- 作者构建的XGBoost预测模型整合了超声造影特征,AUC为0.822,外部验证AUC为0.808,原文认为具有较强预测效度。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: Granulomatous mastitis (GM) is an inflammatory breast condition with high recurrence risk, often complicating management. Existing imaging techniques provide limited predictive insight. This study aims to analyze the correlation between contrast-enhanced ultrasound (CEUS) features and the risk of GM recurrence, developing a predictive model.
METHODS: A retrospective review included 510 patients diagnosed with GM from 2017 to 2022, divided into non-recurrence (non-recurrence, n=389) and recurrence (recurrence, n=121) groups. CEUS was conducted to assess lesion perfusion and enhancement patterns. Key features such as isoenhancement and perfusion defects were analyzed. Correlation analyses, ROC, univariate, and multivariate analyses informed the predictive model construction using XGBoost. External validation was performed to confirm model reliability.
RESULTS: CEUS features like homogeneous (rho=0.137, P=0.002) and heterogeneous isoenhancement (rho=0.134, P=0.002) showed significant correlations with recurrence risk. Perfusion defects (rho=0.127, P=0.004) and not smooth edge lines of defects (rho=0.234, P<0.001) were also associated. The predictive model, integrating CEUS patterns, achieved an area under the curve (AUC) of 0.822, indicating strong predictive validity. External validation confirmed the model's efficacy (AUC=0.808).
CONCLUSION: CEUS imaging reveals specific vascular and enhancement patterns that correlate with the risk of GM recurrence, providing critical diagnostic and prognostic value.
引用
- Ma L, Du P, Sun X, et al. Correlation Analysis and Construction of a Predictive Model Between Contrast-Enhanced Ultrasound Features and the Risk of Recurrence in Granulomatous Mastitis. Acad Radiol. 2025. PMID: 39843281. doi:10.1016/j.acra.2025.01.002
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。