深度学习加速梯度回波序列在子宫MRI中改善图像质量:女性盆腔的首次应用
这项前瞻性研究纳入61例因盆腔MRI转诊的女性患者(最终分析54例),在1.5T扫描仪上比较深度学习加速VIBE与标准VIBE序列在平扫和增强矢状位上的图像质量。三位阅片者独立评估,DL VIBE在几乎所有病例中被首选(平扫99%、增强96%),诊断信心最高(平扫98%、增强90%),图像质量、解剖 delineation 和病灶 demarcation 均显著更优(p<0.01),同时噪声和运动伪影减少。结论认为DL VIBE序列整体改善所有图像质量特征,临床实施可能提高女性盆腔MRI的诊断价值。
要点
- DL VIBE在平扫和增强序列中几乎均被三位阅片者首选(99%和96%)。
- DL VIBE图像质量评分以4分为主(平扫54%、增强78%),ST VIBE以3分为主(平扫53%、增强80%)。
- DL VIBE解剖显示更优(log[OR]=5.3;95%CI:3.7-6.8)且病灶边界更清晰(log[OR]=6.7;95%CI:4.5-8.8),均p<0.01。
核心结论
- DL VIBE序列在所有图像质量特征上对所有阅片者均显示显著整体改善,并在大多数病例中被首选;在女性盆腔MRI中临床实施DL VIBE可能提高检查的诊断价值。
研究设计与样本
- 前瞻性研究,2023年4月至12月纳入61例因盆腔MRI转诊的女性患者(年龄41±14岁),最终分析54例;所有检查使用1.5T MRI扫描仪,采集平扫和增强矢状位DL VIBE与ST VIBE序列;三位阅片者独立使用4分Likert量表评估图像质量。
关键影像表现/征象
- DL VIBE图像质量评分以4分为主(平扫54%、增强78%),ST VIBE以3分为主(平扫53%、增强80%)。
- DL VIBE同时减少噪声和运动伪影(p<0.01)。
- DL VIBE对女性盆腔解剖显示显著更优(p<0.01;log[OR]=5.3;95%CI:3.7-6.8),病灶边界更清晰(p<0.01;log[OR]=6.7;95%CI:4.5-8.8)。
诊断标准与关键数值
- 图像质量采用4分Likert量表评估(1=不可诊断;4=优秀)。
- 运动伪影和噪声采用4分评估(1=无伪影;4=严重伪影)。
- DL VIBE被三位阅片者在几乎所有病例中首选(平扫99%;增强96%),诊断信心最高(平扫98%;增强90%)。
临床应用与阅片要点
- DL VIBE在平扫和增强矢状位子宫MRI中可提供更优的整体图像质量、解剖显示和病灶边界。
- DL VIBE减少噪声和运动伪影,可能有助于提高诊断信心。
- 作者认为在女性盆腔MRI中临床实施DL VIBE可能提高检查的诊断价值。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: The aim of this study was to compare the image quality of a deep learning (DL)-accelerated volumetric interpolated breath-hold examination (VIBE) sequence with a standard (ST) VIBE sequence in assessing the uterus.
MATERIALS AND METHODS: Between April and December 2023, a total of 61 female patients (aged 41 ± 14 years) who were referred for an magnetic resonance imaging (MRI) of the pelvis were included in this prospective study, after providing informed consent. All examinations were performed with a 1.5 T MRI scanner. The DL VIBE and ST VIBE were acquired before (noncontrast [NC]) and after (contrast-enhanced [CE]) contrast administration in the sagittal orientation. Three readers independently evaluated the following aspects of the images' quality using 4-point Likert scales (1 = nondiagnostic; 4 = excellent): global image quality, anatomy delineation, and lesion detection/demarcation. Motion artifacts and noise were also assessed (1 = no artifacts; 4 = severe artifacts). In addition, all three readers selected their preferred sequence and the sequence in which they had the highest diagnostic confidence.
RESULTS: After exclusions, the data for 54 patients were analyzed. The DL VIBE was preferred by all three readers in almost all cases (NC: 99%; CE: 96%) and rated highest for diagnostic confidence (NC: 98%; CE: 90%). The image quality of the DL VIBE was rated statistically significantly better than that of the ST VIBE, with simultaneously reduced noise and motion artifacts (p < 0.01). The image quality of the DL VIBE was predominantly rated with a score of 4 (NC: 54%; CE: 78%), while the image quality of the ST VIBE was mostly rated with a score of 3 (NC: 53%; CE: 80%). The anatomy of the female pelvis was significantly better delineated by the DL VIBE (p < 0.01; log[OR] = 5.3; 95% CI: 3.7-6.8), and lesions were more clearly demarcated (p < 0.01; log[OR] = 6.7; 95% CI: 4.5-8.8).
CONCLUSION: The DL VIBE sequence showed a significant overall improvement in all image quality characteristics for all readers and was preferred in most cases. The clinical implementation of DL VIBE in MRI of the female pelvis could improve the diagnostic value of the examination.
引用
- Hausmann D, Marketin A, Rotzinger R, et al. Improved Image Quality Through Deep Learning Acceleration of Gradient-Echo Acquisitions in Uterine MRI: First Application with the Female Pelvis. Acad Radiol. 2025. PMID: 39843279. doi:10.1016/j.acra.2024.12.021
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。