文献速递妇产影像腹部MR

高分辨率器官轴位T2加权MRI联合FIGO分类用于子宫肌瘤患者的可行性

The feasibility of high-resolution organ-axial T2-weighted MRI when combined with federation of gynecology and obstetrics (FIGO) classification of uterine fibroid patients.
PubMed 文献 · Abdom Radiol (NY) · 2025-01-11

前瞻性纳入130例超声确认的子宫肌瘤患者,比较身体轴位与器官轴位T2WI对FIGO分类的准确性和可靠性,以手术结果为金标准。器官轴位T2WI的观察者间一致性和与手术描述的一致性均优于身体轴位,FIGO分类准确率达92.9%。器官轴位T2WI有助于术前FIGO分类和治疗计划。

要点

  • 器官轴位T2WI对子宫肌瘤FIGO分类的准确率为92.9%,高于身体轴位T2WI(P<0.01)。
  • 器官轴位T2WI观察者间一致性kappa值为0.877(P=0.04),与手术描述一致性kappa值为0.932(P=0.037)。
  • 32个(38.1%)肌瘤在器官轴位T2WI上显示宫腔变形,压缩角与FIGO类型呈线性相关(P<0.001)。

核心结论

  • 与身体轴位T2WI相比,器官轴位T2WI基于FIGO分类的准确性更高,且与手术结果更一致。
  • 鉴于术前FIGO分类具有优异的可靠性和准确性,器官轴位T2WI可有助于治疗计划。

研究设计与样本

  • 前瞻性研究,2023年3月至2024年5月纳入130例超声确认的子宫肌瘤患者,共170个肌瘤。
  • 患者接受MR检查,包括身体轴位T2W(矢状位和轴位)和器官轴位T2W(高分辨率斜冠状位和双斜轴位)。
  • 以手术结果为金标准,比较轴位和器官轴位T2W评估FIGO分类的准确性。
  • 采用kappa统计评估两名放射科医生间及两种MR检查与手术描述间的一致性。

关键影像表现/征象

  • 器官轴位T2WI显示32个(38.1%)肌瘤存在宫腔变形,包括FIGO 0-7型和2-5型肌瘤。
  • 肌瘤大小(S)、基底宽度(B)、压缩深度(D)、D/B、D/S和压缩角(A)在不同FIGO类型肌瘤间差异显著(P<0.05)。
  • 压缩角与FIGO类型呈线性相关(P<0.001)。

诊断标准与关键数值

  • 器官轴位T2WI评估FIGO分类的准确率为92.9%(P<0.01),高于身体轴位T2WI。
  • 器官轴位T2WI观察者间一致性kappa值为0.877(P=0.04),与手术描述一致性kappa值为0.932(P=0.037)。
  • 身体轴位T2WI的观察者间一致性和与手术描述一致性均低于器官轴位T2WI。

临床应用与阅片要点

  • 术前采用器官轴位高分辨率T2WI(斜冠状位和双斜轴位)评估子宫肌瘤,可提高FIGO分类与手术结果的一致性。
  • 关注肌瘤大小、基底宽度、压缩深度、D/B、D/S和压缩角等参数,这些参数在不同FIGO类型间存在显著差异。
  • 压缩角与FIGO类型呈线性相关,可作为辅助判断指标。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Correctly classifying uterine fibroids is essential for treatment planning. The objective of this study was to assess the accuracy and reliability of the FIGO classification system in categorizing uterine fibroids via organ-axial T2WI and to further investigate the factors associated with uterine compression.

METHODS: A total of 130 patients with ultrasound-confirmed fibroids were prospectively enrolled between March 2023 and May 2024. These patients underwent MR examinations, including body-axial T2W (sagittal and axial) and organ-axial T2W (high resolution with oblique coronal and double oblique axial). For postprocessing, the interobserver agreements between two radiologists and the interagreements between two MR examinations and operational descriptions were evaluated via kappa statistics. The accuracy of axial and organ-axial T2W assessments in the FIGO classification of uterine fibroids was compared when surgical outcomes were used as the gold standard. The Kruskal‒Wallis test was used to compare the differences in cavity deformation across various FIGO classifications. Spearman's rank correlation test was used to analyze the correlation between the FIGO classification and the parameters of uterine cavity deformation.

RESULTS: In total, 170 fibroids from 130 patients were included. Compared with body-axial T2WI, organ-axial T2WI showed better interobserver agreement and greater interagreements with operational descriptions, with kappa values of 0.877 (P = 0.04) and 0.932 (P = 0.037), respectively. The accuracy of the organ-axial T2WI assessment in determining the FIGO classification of uterine fibroids was greater than that of the body-axial T2WI assessment, with an accuracy of 92.9% (P < 0.01). Thirty-two (38.1%) fibroids showed cavity deformation according to organ-axial T2WI, including fibroids with FIGO types 0-7 and 2-5. Among these factors, the size of the fibroids (S), base width (B), depth of compression (D), D/B, D/S, and compression angle (A) significantly differed among the different FIGO types of fibroids (P < 0.05). Compression angle exhibited a linear correlation with the FIGO type (P < 0.001).

CONCLUSION: Compared with body-axial T2WI, organ-axial T2WI provides greater accuracy on the basis of the FIGO classification, which is more consistent with surgical outcomes. Given the excellent reliability and accuracy of the preoperative FIGO classification, organ-axial T2WI can contribute to treatment planning.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Liu X, Wang K, Gou X, et al. The feasibility of high-resolution organ-axial T2-weighted MRI when combined with federation of gynecology and obstetrics (FIGO) classification of uterine fibroid patients. Abdom Radiol (NY). 2025. PMID: 39794535. doi:10.1007/s00261-024-04776-w

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。