多参数MRI联合影像组学用于子宫内膜纤维化的诊断与分级
前瞻性纳入74例重度子宫内膜纤维化、41例轻中度纤维化(均经宫腔镜证实)及40例健康育龄女性,按7:3分为训练集108例和测试集47例,均行T2和DWI序列扫描。提取影像组学特征并用两种特征选择方法与四种机器学习分类器两两组合建立40个分类模型,其中无监督特征选择联合逻辑回归(UFS-LR)表现最佳,测试集平均AUC为0.92。由UFS-LR构建的五个模型中,模型1(T2+ADC+临床数据)表现最好,平均AUC、F1-score和ACC分别为0.92、0.80和0.81。T2相关特征在区分纤维化程度中最重要,其中T2_wavelet-LLL_gldm_DependenceVariance为最重要特征。
要点
- UFS-LR联合模型在测试集平均AUC达0.92,模型1(T2+ADC+临床数据)平均AUC、F1-score、ACC分别为0.92、0.80、0.81。
- T2相关特征对区分纤维化程度最重要,其中T2_wavelet-LLL_gldm_DependenceVariance为最重要特征。
- 多参数MRI影像组学联合机器学习在子宫内膜纤维化分级中表现优异,有望减少对宫腔镜的依赖。
核心结论
- 多参数MRI影像组学联合机器学习在子宫内膜纤维化分级中表现优异,该方法无创,有望减少对宫腔镜的依赖。
研究设计与样本
- 前瞻性研究,纳入74例重度子宫内膜纤维化、41例轻中度纤维化(经宫腔镜证实)及40例健康育龄女性,按7:3随机分层分为训练集108例(健康28例、轻中度29例、重度51例)和测试集47例(健康12例、轻中度12例、重度23例),所有参与者行T2和DWI序列扫描,参考标准为宫腔镜。
关键影像表现/征象
- 在三个亚组中自由勾画子宫内膜感兴趣体积(VOI)后提取并筛选影像组学特征。
- T2相关特征在区分纤维化程度中最重要,其中T2_wavelet-LLL_gldm_DependenceVariance为最重要特征。
诊断标准与关键数值
- UFS-LR模型在测试集平均AUC为0.92。
- UFS-LR构建的五个模型中,模型1(T2+ADC+临床数据)平均AUC、F1-score和ACC分别为0.92、0.80和0.81。
临床应用与阅片要点
- 多参数MRI影像组学联合机器学习可用于子宫内膜纤维化的无创分级评估。
- T2相关影像组学特征,尤其是T2_wavelet-LLL_gldm_DependenceVariance,在区分纤维化程度中价值最高。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To evaluate the application of multi-parametric MRI (MP-MRI) combined with radiomics in diagnosing and grading endometrial fibrosis (EF).
METHODS: A total of 74 patients with severe endometrial fibrosis (SEF), 41 patients with mild to moderate fibrosis (MMEF) confirmed by hysteroscopy, and 40 healthy women of reproductive age were prospectively enrolled. The enrolled data were randomly stratified and divided into a train set (108 cases: 28 healthy women, 29 with MMEF, and 51 with SEF) and a test set (47 cases: 12 healthy women, 12 MMEF and 23 SEF) at a ratio of 7:3. All participants underwent T2 and DWI sequence scans. By freely delineating the volume of interest (VOI) of the endometrium in three subgroups, radiomic features were extracted and selected. Two feature selection methods and four machine learning (ML) classifiers were combined in pairs to establish five prediction models [model1 (T2 + ADC + clinical data), model2 (T2 + ADC), model3 (T2), model4 (ADC), and model5 (clinical data)], resulting in a total of 40 classification models. The predictive performance of all models was evaluated using the area under the curve (AUC), F1-score, and accuracy (ACC).
RESULTS: The "UFS-LR" model, which combined unsupervised feature selection (UFS) with the logistic regression (LR) classifier, performed the best, with an average AUC of 0.92 on the test set. Among the five models constructed via UFS-LR, model1 exhibited the best performance, with average AUC, F1-score, and ACC values of 0.92, 0.80, and 0.81, respectively. T2-related features were the most significant in distinguishing fibrosis levels, with T2_wavelet-LLL_gldm_DependenceVariance being the most important characteristic among them.
CONCLUSION: MP-MRI radiomics analysis using ML has excellent performance in grading EF. This approach is non-invasive and has the potential to reduce the reliance on hysteroscopy.
引用
- Wang H, Zhu L, Zhu H, et al. Multi-parametric MRI combined with radiomics for the diagnosis and grading of endometrial fibrosis. Abdom Radiol (NY). 2025. PMID: 39841225. doi:10.1007/s00261-024-04785-9
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。