文献速递泌尿生殖妇产影像US

卵巢-附件报告和数据系统超声的阅片者间可靠性:系统综述与荟萃分析

Inter-reader reliability of Ovarian-Adnexal Reporting and Data System US: a systematic review and meta-analysis.
PubMed 文献 · Abdom Radiol (NY) · 2025-01-22

该系统综述与荟萃分析纳入14篇原始文献共5139个卵巢及附件病变,评估O-RADS US分类的阅片者间可靠性。汇总可靠性为0.83(95% CI 0.78-0.88),提示几乎完美可靠性,但研究间异质性显著(I²=96.9),阅片者经验是唯一相关因素;有经验阅片者汇总可靠性0.86(95% CI 0.81-0.91)高于含受训者的多阅片者0.74(95% CI 0.70-0.78;P=0.009)。

要点

  • O-RADS US分类汇总阅片者间可靠性0.83(95% CI 0.78-0.88),达几乎完美水平。
  • 有经验阅片者汇总可靠性0.86(95% CI 0.81-0.91)高于含受训者0.74(95% CI 0.70-0.78;P=0.009)。
  • 超声描述词可靠性范围0.39-0.97,腹水和腹膜结节达几乎完美(0.79-0.97)。

核心结论

  • O-RADS US风险分层系统在病变分类中显示几乎完美的阅片者间可靠性。
  • 结果强调针对性培训和描述词简化对提高阅片者间可靠性和临床采用的重要性。

研究设计与样本

  • 系统综述与荟萃分析,检索MEDLINE、EMBASE和Web of Science数据库2018年1月至2023年12月的原始文献。
  • 共纳入14篇原始文献,包含5139个卵巢及附件病变。
  • 采用DerSimonian-Laird随机效应模型确定O-RADS US分类的汇总阅片者间可靠性,并行亚组荟萃回归分析探讨异质性来源。

关键影像表现/征象

  • O-RADS US病变分类的阅片者间可靠性范围为0.71至0.99。
  • 超声描述词的阅片者间可靠性范围为0.39至0.97。
  • 腹水和腹膜结节的可靠性达几乎完美水平(0.79-0.97)。

诊断标准与关键数值

  • O-RADS US分类汇总阅片者间可靠性为0.83(95% CI 0.78-0.88),提示几乎完美可靠性。
  • 有经验阅片者研究的汇总可靠性为0.86(95% CI 0.81-0.91)。
  • 含受训者的多阅片者研究的汇总可靠性为0.74(95% CI 0.70-0.78),低于有经验阅片者研究(P=0.009)。

临床应用与阅片要点

  • 阅片者经验是影响O-RADS US分类可靠性的因素,有经验阅片者可靠性更高。
  • 作者认为针对性培训和描述词简化可提高阅片者间可靠性和临床采用。

局限性

  • 研究间异质性显著(I²=96.9)。
  • 亚组荟萃回归分析中,阅片者经验是唯一与 study heterogeneity 相关的因素。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Ovarian-Adnexal Reporting and Data System (O-RADS) US provides a standardized lexicon for ovarian and adnexal lesions, facilitating risk stratification based on morphological features for malignancy assessment, which is essential for proper management. However, systematic determination of inter-reader reliability in O-RADS US categorization remains unexplored. This study aimed to systematically determine the inter-reader reliability of O-RADS US categorization and identify the factors that affect it.

METHODS: Original articles reporting the inter-reader reliability of O-RADS US in lesion categorization were identified in the MEDLINE, EMBASE, and Web of Science databases from January 2018 to December 2023. DerSimonian-Laird random-effects models were used to determine the meta-analytic pooled inter-reader reliability of the O-RADS US categorization. Subgroup meta-regression analysis was performed to identify the factors causing study heterogeneity.

RESULTS: Fourteen original articles with 5139 ovarian and adnexal lesions were included. The inter-reader reliability of O-RADS US in lesion categorization ranged from 0.71 to 0.99, with a meta-analytic pooled estimate of 0.83 (95% CI, 0.78-0.88), indicating almost perfect reliability. Substantial study heterogeneity was observed in the inter-reader reliability of the O-RADS US categorization (I2 = 96.9). In subgroup meta-regression analysis, reader experience was the only factor associated with study heterogeneity. Pooled inter-reader reliability of the O-RADS US categorization was higher in studies with all experienced readers (0.86; 95% CI, 0.81-0.91) compared to those with multiple readers including trainees (0.74; 95% CI, 0.70-0.78; P = 0.009). The inter-reader reliability of US descriptors ranged from 0.39 to 0.97, with ascites and peritoneal nodules showing almost perfect reliability (0.79- 0.97).

CONCLUSION: The O-RADS US risk stratification system demonstrated almost perfect inter-reader reliability in lesion categorization. Our results highlight the importance of targeted training and descriptor simplification to improve inter-reader reliability and clinical adoption.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Bae SM, Kim DH, Kang JH, et al. Inter-reader reliability of Ovarian-Adnexal Reporting and Data System US: a systematic review and meta-analysis. Abdom Radiol (NY). 2025. PMID: 39841229. doi:10.1007/s00261-025-04813-2

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。