文献速递外周血管介入US

剪切波弹性成像在动静脉内瘘血栓形成中的应用:区分血栓时相并评估球囊血管成形术的临床结局

Shear Wave Elastography in AV Fistula Thrombosis: Differentiating Thrombus Age and Assessing Clinical Outcomes of Balloon Angioplasty.
PubMed 文献 · J Ultrasound Med · 2025-01-09

回顾性纳入44例动静脉内瘘血栓形成的透析患者,用剪切波弹性成像测量血栓硬度并据超声和临床病史分为急性(23例)与亚急性(21例)组,随后行球囊血管成形术。亚急性组剪切波弹性成像平均、中位及最大kPa值均显著高于急性组(P<.001),血栓时相与kPa值呈强正相关,平均截断值31.733 kPa区分急亚急性血栓的敏感度90.5%、特异度73.9%。剪切波弹性成像值与手术结局无显著相关(P>.05),作者认为其有助于血栓特征描述和治疗计划,但未预测手术成功。

要点

  • 亚急性血栓的剪切波弹性成像平均、中位及最大kPa值均显著高于急性血栓(P<.001)。
  • 平均kPa截断值31.733 kPa区分急亚急性血栓的敏感度90.5%、特异度73.9%。
  • 剪切波弹性成像值与球囊血管成形术结局无显著相关(P>.05)。

核心结论

  • 剪切波弹性成像似乎是有前景的动静脉内瘘血栓时相评估工具,能有效区分急性与亚急性血栓,虽未预测手术成功,但可补充现有影像以改善血栓特征描述和治疗计划。

研究设计与样本

  • 回顾性研究,纳入2022年6月至2024年6月44例动静脉内瘘血栓形成的透析患者,行多普勒超声和剪切波弹性成像评估血栓时相后行球囊血管成形术,据超声表现和临床病史分为急性与亚急性血栓组。

关键影像表现/征象

  • 亚急性血栓的剪切波弹性成像平均、中位及最大kPa值均显著高于急性血栓(P<.001)。
  • 血栓时相与剪切波弹性成像kPa值呈强正相关(r=.770、r=.727、r=.835)。

诊断标准与关键数值

  • 剪切波弹性成像平均截断值31.733 kPa区分急性与亚急性血栓,敏感度90.5%、特异度73.9%。

临床应用与阅片要点

  • 剪切波弹性成像可能补充现有影像用于改善动静脉内瘘血栓的特征描述和治疗计划。
  • 剪切波弹性成像值未显示与球囊血管成形术结局相关(P>.05),不能据此预测手术成功。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To evaluate the role of shear wave elastography (SWE) in distinguishing acute from subacute thrombi in thrombosed arteriovenous fistulas (AVFs) and explore the relationship between thrombus stiffness and outcomes of balloon angioplasty.

MATERIALS AND METHODS: This retrospective study included 44 dialysis patients with thrombosed AVFs from June 2022 to June 2024. Patients underwent Doppler ultrasound and SWE to assess thrombus age, followed by balloon angioplasty. Based on ultrasound findings and clinical history, patients were classified into acute and subacute thrombus groups. SWE was used to measure thrombus stiffness (kPa values). Procedural outcomes, including technical and clinical success, and primary and secondary patency, were compared between groups.

RESULTS: The study included 23 patients with acute and 21 with subacute thrombus. SWE measurements (average, median, and maximum kPa) were significantly higher in subacute thrombi (P < .001). A strong positive correlation existed between thrombus age and kPa values (r = .770, r = .727, r = .835). Receiver operating characteristic analysis showed SWE could effectively distinguish acute from subacute thrombi, with an average cut-off of 31.733 kPa (sensitivity: 90.5%, specificity: 73.9%). No significant correlation was found between SWE values and procedural outcomes (P > .05).

CONCLUSION: SWE is a promising tool for assessing thrombus age in AVF thrombosis, effectively differentiating between acute and subacute thrombi. Although it did not predict procedural success, SWE could complement existing imaging for improved thrombus characterization and treatment planning.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Dablan A, Özdemir MŞ, Karagülle M, et al. Shear Wave Elastography in AV Fistula Thrombosis: Differentiating Thrombus Age and Assessing Clinical Outcomes of Balloon Angioplasty. J Ultrasound Med. 2025. PMID: 39786149. doi:10.1002/jum.16643

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。