文献速递泌尿生殖腹部MR

直肠内线圈使用对前列腺MRI检测包膜外侵犯的影响:一项回顾性单中心研究

Impact of Endorectal Coil Use on Extraprostatic Extension Detection in Prostate MRI: A Retrospective Monocentric Study.
PubMed 文献 · Acad Radiol · 2025-01-13

该回顾性单中心研究纳入2007至2024年间接受mpMRI及根治性前列腺切除术的前列腺癌患者934例,按是否使用直肠内线圈(ERC)分组,由一名放射科医生采用NCI EPE分级系统评估。结果显示,在NCI EPE分级≥1时,ERC组敏感度(75% vs 62%)和阴性预测值(91% vs 83%)高于非ERC组;在分级=3时,ERC组阴性预测值(83% vs 75%)和准确率(80% vs 74%)更高。多因素逻辑回归显示,无论是否使用ERC,较高的NCI EPE分级均为病理学EPE的强独立预测因子。

要点

  • 在NCI EPE分级≥1时,ERC组敏感度75%、阴性预测值91%,均高于非ERC组(62%、83%)。
  • 在NCI EPE分级=3时,ERC组阴性预测值83%、准确率80%,均高于非ERC组(75%、74%)。
  • 无论是否使用ERC,较高的NCI EPE分级均为病理学EPE的独立预测因子。

核心结论

  • 使用ERC可提高mpMRI在不同NCI EPE阈值下检测EPE的敏感度、阴性预测值和准确率;无论是否使用ERC,NCI EPE分级系统仍是病理学EPE更强的独立预测因子。

研究设计与样本

  • 回顾性研究,采用前瞻性收集的数据,纳入2007至2024年间接受mpMRI及后续根治性前列腺切除术的前列腺癌患者934例,按是否使用ERC分为非ERC组(n=322)和ERC组(n=612);以全mount组织病理学为参考标准判定病理学EPE,由一名放射科医生采用本机构(美国国家癌症研究所[NCI])EPE分级系统评估mpMRI;采用逻辑回归分析病理学EPE的显著预测因子,包括ERC使用和NCI EPE分级。

诊断标准与关键数值

  • 在NCI EPE分级≥1时,ERC组敏感度75%(101/134) vs 非ERC组62%(56/90),p=0.04;ERC组阴性预测值91%(320/353) vs 非ERC组83%(166/200),p=0.01。在NCI EPE分级=3时,ERC组阴性预测值83%(452/546) vs 非ERC组75%(221/294),p=0.01;ERC组准确率80%(492/612) vs 非ERC组74%(238/322),p=0.03。多因素逻辑回归中,NCI EPE分级2级使用ERC时OR=2.01,p=0.04;未使用ERC时OR=5.63,p<0.001;NCI EPE分级3级使用ERC时OR=4.53,p<0.001;未使用ERC时OR=5.22,p=0.002。

临床应用与阅片要点

  • 作者指出,使用ERC可提高mpMRI检测EPE的敏感度、阴性预测值和准确率;无论是否使用ERC,NCI EPE分级系统仍是病理学EPE更强的独立预测因子。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: Accurate preoperative mpMRI-based detection of extraprostatic extension (EPE) in prostate cancer (PCa) is critical for surgical planning and patient outcomes. This study aims to evaluate the impact of endorectal coil (ERC) use on the diagnostic performance of mpMRI in detecting EPE.

MATERIALS AND METHODS: This retrospective study with prospectively collected data included participants who underwent mpMRI and subsequent radical prostatectomy for PCa between 2007 and 2024. Participants were divided based on ERC use on mpMRI: MRI without ERC and with ERC. Surgical pathology reports were used to determine the patients with pathologic EPE on whole-mount histopathology. One radiologist evaluated mpMRI using an in-house (National Cancer Institute [NCI]) EPE grading system. Logistic regression (LR) analyses were conducted to identify significant predictors of pathologic EPE, including ERC use and NCI EPE grades.

RESULTS: 934 men (median age: 62 years [IQR = 57-67]) were included. For NCI EPE grade≥1, ERC MRI group (n = 612) had higher NPV (91% [320/353] vs. 83% [166/200], p = 0.01) and sensitivity (75% [101/134] vs. 62% [56/90], p = 0.04) compared to non-ERC group (n = 322). For NCI EPE grade = 3, ERC MRI group had higher NPV (83% [452/546] vs. 75% [221/294], p = 0.01) and accuracy (80% [492/612] vs. 74% [238/322], p = 0.03). In multivariable LR, higher NCI EPE grades were strong independent predictors of pathologic EPE, irrespective of ERC use (NCI EPE grade 2 with ERC: odds ratio [OR] = 2.01, p = 0.04; without ERC: OR = 5.63, p<0.001, NCI EPE grade 3 with ERC: OR = 4.53, p<0.001; without ERC: OR = 5.22, p = 0.002).

CONCLUSION: ERC improves sensitivity, NPV, accuracy of EPE detection with mpMRI at different NCI EPE thresholds. NCI EPE grading system remains the stronger independent predictor of pathologic EPE regardless of ERC use.

来源:Acad Radiol,查看原文。版权归原作者所有。