探索ADC值与bp-MRI VI-RADS联合诊断模型在评估膀胱癌肌层浸润中的潜力
单中心回顾性研究纳入81例经病理确诊的膀胱癌患者,评估bp-MRI VI-RADS诊断肌层浸润的效能,并构建ADC值与VI-RADS联合的简易模型。bp-MRI VI-RADS的AUC为0.886,ADC值为0.899,联合模型AUC达0.942,DeLong检验显示联合模型与单独bp-MRI VI-RADS的AUC差异有统计学意义(P < 0.05)。
要点
- bp-MRI VI-RADS诊断膀胱癌肌层浸润的AUC为0.886,敏感度0.962,特异度0.655。
- ADC值诊断肌层浸润的AUC为0.899,敏感度0.846,特异度0.891。
- ADC值与bp-MRI VI-RADS联合模型AUC为0.942,优于单独bp-MRI VI-RADS(P < 0.05)。
核心结论
- 无对比剂bp-MRI VI-RADS对膀胱癌肌层浸润具有值得肯定的诊断效能,ADC值可补充bp-MRI VI-RADS并提升诊断表现。
研究设计与样本
- 单中心回顾性研究,纳入2019年10月至2021年11月81例经病理确诊的膀胱癌患者,两位阅片者独立依据VI-RADS标准对T2加权成像和扩散加权成像评分并得出bp-MRI VI-RADS评分,以病理为参考标准,采用logistic回归构建ADC值与bp-MRI VI-RADS的简易联合模型。
诊断标准与关键数值
- bp-MRI VI-RADS诊断肌层浸润的AUC为0.886(95%CI:0.801-0.971),诊断准确率0.753、敏感度0.962、特异度0.655;ADC值的AUC为0.899(95%CI:0.821-0.977),诊断准确率0.877、敏感度0.846、特异度0.891;简易联合模型的AUC为0.942(95%CI:0.881-0.999),诊断准确率0.889、敏感度0.885、特异度0.891;DeLong检验显示联合模型与单独bp-MRI VI-RADS的AUC差异有统计学意义(P < 0.05)。
临床应用与阅片要点
- 作者认为无对比剂bp-MRI VI-RADS对诊断膀胱癌肌层浸润具有值得肯定的诊断效能,ADC值可补充bp-MRI VI-RADS并提升诊断表现;简易联合模型经DCA和校准曲线显示具有良好的临床适用性。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: This study investigates the diagnostic value of Vesical Imaging Reporting and Data System (VI-RADS) in biparametric MRI (bp-MRI) for the detection of muscular infiltration in bladder cancer, and to investigate whether apparent diffusion coefficient (ADC) value can function as a potential indicator of bp-MRI VI-RADS for patient benefit.
MATERIALS AND METHODS: This single-center retrospective study enrolled 81 patients with pathologically confirmed bladder cancer from October 2019 to November 2021. Two readers independently scored the T2-weighted images and diffusion-weighted images of each index lesion based on the VI-RADS criteria, subsequently deriving the bp-MRI VI-RADS scores. Both ADC values and bp-MRI VI-RADS scores were utilized to develop a simple model by logistic regression. Receiver-operating characteristic curve assessed all systems, while decision curve analysis (DCA) and calibration curves evaluated the model's performance.
RESULTS: The area under the curve (AUC) of bp-MRI VI-RADS was 0.886 (95% confidence interval [CI]: 0.801-0.971), with the diagnostic accuracy, sensitivity, and specificity being 0.753, 0.962, and 0.655 respectively. Regarding the ADC value, its AUC was 0.899 (95% CI: 0.821-0.977), and the diagnostic accuracy, sensitivity, and specificity were 0.877, 0.846, and 0.891. The AUC of the simple combined model achieved 0.942 (95% CI: 0.881-0.999), and the diagnostic accuracy, sensitivity, and specificity were 0.889, 0.885, and 0.891. The DeLong test verified that there was a statistically significant difference in AUC between the model and bp-MRI VI-RADS alone (P < 0.05). The simple model demonstrated excellent clinical applicability via DCA and calibration plots.
CONCLUSIONS: The contrast-free bp-MRI VI-RADS demonstrates commendable diagnostic efficacy for diagnosing muscular infiltration in bladder cancer. Additionally, ADC values can complement bp-MRI VI-RADS, enhancing diagnostic performance.
引用
- Zhang Z, Xiao W, Wang Y, et al. Exploring the potential of the combined diagnostic model of ADC value and bp-MRI VI-RADS in the evaluation of muscle invasion in bladder Cancer. Abdom Radiol (NY). 2025. PMID: 39745530. doi:10.1007/s00261-024-04788-6
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。