Dixon MRI联合深度学习提升2型糖尿病胰腺内脂肪沉积自动监测的准确性与稳定性
本研究为回顾性研究,纳入两中心534例接受上腹部MRI及多回波与双回波Dixon序列的患者,基于双回波Dixon水图像训练nnU-Net胰腺分割模型并配准至多回波Dixon的PDFF图,构建深度学习影像组学模型区分2型糖尿病与非糖尿病及糖尿病前期,并将其与两位放射科医师基于三个胰腺感兴趣区平均PDFF的模型比较。
要点
- 胰腺分割平均Dice相似系数在总测试队列为0.958。
- 区分2型糖尿病与非糖尿病及糖尿病前期,DLR模型在训练队列AUC为0.868,外部测试队列为0.741。
- 两位放射科医师胰腺PDFF测量的组内相关系数在两中心分别为0.800和0.699,提示重复性良好与中等。
核心结论
- DLR模型表现优于放射科医师,为监测胰腺内脂肪沉积及预测2型糖尿病和糖尿病前期风险提供了更高效、准确和稳定的方法,使胰腺内脂肪沉积评估可能作为2型糖尿病的早期生物标志物。
研究设计与样本
- 回顾性研究,纳入两中心534例接受上腹部MRI并完成多回波与双回波Dixon序列的患者,以双回波Dixon水图像训练nnU-Net胰腺分割模型,将预测掩膜配准至多回波Dixon的PDFF图。
诊断标准与关键数值
- 区分2型糖尿病与非糖尿病及糖尿病前期,DLR模型AUC在训练队列为0.868,外部测试队列为0.741;两位放射科医师模型AUC在训练队列分别为0.760和0.782,外部测试队列分别为0.724和0.653。
- 区分糖尿病前期与非糖尿病,DLR模型AUC在训练队列为0.881,两位放射科医师模型AUC均为0.688,训练队列包含两中心合并数据;因糖尿病前期患者有限未进行测试。
- 胰腺分割平均Dice相似系数在总测试队列为0.958。
- 两位放射科医师胰腺PDFF测量的组内相关系数在两中心分别为0.800和0.699,提示重复性良好与中等。
局限性
- 因糖尿病前期患者有限,区分糖尿病前期与非糖尿病的模型未进行测试。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: Intra-pancreatic fat deposition (IPFD) is closely associated with the onset and progression of type 2 diabetes mellitus (T2DM). We aimed to develop an accurate and automated method for assessing IPFD on multi-echo Dixon MRI.
MATERIALS AND METHODS: In this retrospective study, 534 patients from two centers who underwent upper abdomen MRI and completed multi-echo and double-echo Dixon MRI were included. A pancreatic segmentation model was trained on double-echo Dixon water images using nnU-Net. Predicted masks were registered to the proton density fat fraction (PDFF) maps of the multi-echo Dixon sequence. Deep semantic segmentation feature-based radiomics (DSFR) and radiomics features were separately extracted on the PDFF maps and modeled using the support vector machine method with 5-fold cross-validation. The first deep learning radiomics (DLR) model was constructed to distinguish T2DM from non-diabetes and pre-diabetes by averaging the output scores of the DSFR and radiomics models. The second DLR model was then developed to distinguish pre-diabetes from non-diabetes. Two radiologist models were constructed based on the mean PDFF of three pancreatic regions of interest.
RESULTS: The mean Dice similarity coefficient for pancreas segmentation was 0.958 in the total test cohort. The AUCs of the DLR and two radiologist models in distinguishing T2DM from non-diabetes and pre-diabetes were 0.868, 0.760, and 0.782 in the training cohort, and 0.741, 0.724, and 0.653 in the external test cohort, respectively. For distinguishing pre-diabetes from non-diabetes, the AUCs were 0.881, 0.688, and 0.688 in the training cohort, which included data combined from both centers. Testing was not conducted due to limited pre-diabetic patients. Intraclass correlation coefficients between radiologists' pancreatic PDFF measurements were 0.800 and 0.699 at two centers, suggesting good and moderate reproducibility, respectively.
CONCLUSION: The DLR model demonstrated superior performance over radiologists, providing a more efficient, accurate and stable method for monitoring IPFD and predicting the risk of T2DM and pre-diabetes. This enables IPFD assessment to potentially serve as an early biomarker for T2DM, providing richer clinical information for disease progression and management.
引用
- Pan Z, Chen Q, Lin H, et al. Enhanced accuracy and stability in automated intra-pancreatic fat deposition monitoring of type 2 diabetes mellitus using Dixon MRI and deep learning. Abdom Radiol (NY). 2025. PMID: 39841227. doi:10.1007/s00261-025-04804-3
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。