视听呼吸引导用于改善肝脏T2加权和扩散加权MRI的图像质量与扫描效率
前瞻性研究纳入32例有肝脏MRI临床指征的患者,在3 T MRI上比较标准触发与磁体内视听主动呼吸引导的呼吸触发T2加权和扩散加权序列。呼吸引导组伪影更少、图像质量更优,T2和DWI扫描时间分别缩短17%和37%,表观信噪比和表观对比噪声比无显著差异。
要点
- 呼吸引导组T2和DWI伪影更少、图像质量更优。
- 呼吸引导组T2和DWI扫描时间分别缩短17%和37%。
- 两组表观信噪比和表观对比噪声比无显著差异。
核心结论
- 对呼吸触发肝脏T2加权和扩散加权序列采用主动呼吸引导,与标准采集相比可显著减少呼吸伪影、改善图像质量并缩短扫描时间。
研究设计与样本
- 前瞻性研究,随机纳入32例有肝脏MRI临床指征的患者,在3 T MRI上采集标准触发与呼吸引导的T2加权和扩散加权序列;呼吸引导应用从扫描仪接收呼吸信号,通过检查孔后方的镜子和屏幕显示动画呼吸指令,并在DWI BG和T2 BG采集前播放短片;T2 BG和DWI BG的呼吸模式参数根据患者身体呼吸能力个体化设定,即4秒呼吸后4.5秒屏气。
关键影像表现/征象
- T2 BG较T2 S伪影更少(4.5 ± 0.7 vs 4.1 ± 0.8,P < 0.001),锐利度、病灶显示度和整体图像质量更优(如整体图像质量4.6 ± 0.7 vs 4.4 ± 0.7,P = 0.004)。
- DWI BG较DWI S所有类别图像质量均改善(如整体图像质量4.5 ± 0.5 vs 4.3 ± 0.5,P = 0.005),伪影更少(4.1 ± 0.5 vs 3.8 ± 0.7,P = 0.007)。
- T2 BG扫描时间286 ± 23秒 vs T2 S 345 ± 68秒(P < 0.001),缩短17%;DWI BG扫描时间160 ± 4秒 vs DWI S 252 ± 70秒(P < 0.001),缩短37%。
- 两种序列两种方法的表观信噪比和表观对比噪声比相似(如表观信噪比:23.45 ± 11.31 [T2 BG] vs 25.84 ± 10.76 [T2 S],P = 0.079)。
临床应用与阅片要点
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: Impaired image quality and long scan times frequently occur in respiratory-triggered sequences in liver magnetic resonance imaging (MRI). We evaluated the impact of an in-bore active breathing guidance (BG) application on image quality and scan time of respiratory-triggered T2-weighted (T2) and diffusion-weighted imaging (DWI) by comparing sequences with standard triggering (T2 S and DWI S ) and with BG (T2 BG and DWI BG ).
MATERIALS AND METHODS: In this prospective study, random patients with clinical indications for liver MRI underwent 3 T MRI with standard and BG acquisitions. The audiovisual BG application received the respiratory signal from the scanner, and animated breathing instructions were displayed using a mirror and screen behind the MRI bore. Prior to the DWI BG and T2 BG acquisition, patients received a short video instruction about MRI with BG. Suitable parameters for desired breathing pattern for T2 BG and DWI BG were set individually for each patient based on the patient's physical respiratory ability (ie, 4 seconds breathing followed by 4.5 seconds breath holding). Artifacts, sharpness, lesion conspicuity, and overall image quality were assessed using a Likert scale from 1 (nondiagnostic) to 5 (excellent). Scan time, apparent contrast-to-noise ratio, and apparent signal-to-noise ratio (aSNR) for all sequences were analyzed. Paired t test and Wilcoxon test were used for statistical analysis.
RESULTS: Thirty-two patients (mean age: 55 ± 13 years, 13 female) were included. T2 BG showed less artifacts (4.5 ± 0.7 vs 4.1 ± 0.8, P < 0.001) and better sharpness, lesion conspicuity, and overall image quality (eg, overall image quality 4.6 ± 0.7 vs 4.4 ± 0.7, P = 0.004) compared with T2 S . DWI BG demonstrated improved image quality in all categories compared with DWI S (eg, overall image quality 4.5 ± 0.5 vs 4.3 ± 0.5, P = 0.005) and less artifacts (4.1 ± 0.5 vs 3.8 ± 0.7, P = 0.007). Scan times of T2 BG (286 ± 23 vs 345 ± 68 seconds, P < 0.001) and DWI BG (160 ± 4 vs 252 ± 70 seconds, P < 0.001) were reduced by 17% and 37%, respectively. aSNR and apparent contrast-to-noise ratio (eg, aSNR: 23.45 ± 11.31 [T2 BG ] vs 25.84 ± 10.76 [T2 S ]; P = 0.079) were similar for both sequences for both approaches.
CONCLUSIONS: Active BG for respiratory-triggered liver T2w and DWI sequences led to significant reduction of breathing artifacts, improved image quality, and shorter scan time compared with standard acquisitions.
引用
- Mesropyan N, Katemann C, Heuvelink-Marck A, et al. Audiovisual Breathing Guidance for Improved Image Quality and Scan Efficiency of T2- and Diffusion-Weighted Liver MRI. Invest Radiol. 2025. PMID: 39804794. doi:10.1097/RLI.0000000000001150
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。