超声造影定量参数对肝移植术后缺血型胆道病变的评估价值:一项前瞻性研究

Evaluation value of contrast enhanced ultrasound quantitative parameters in ischemic-type biliary lesions after liver transplantation-a prospectively study.
PubMed 文献 · Abdom Radiol (NY) · 2025-01-25

前瞻性纳入35例肝移植患者,其中15例经MRCP/ERCP/PTC确诊缺血型胆道病变(ITBLs),30例正常胆道为对照。超声造影定量分析显示ITBLs组动态血管模式曲线为负向波,正常胆道组为正向波;ITBLs组IMAX、Rs50、AUC、WinAUC、WinR、Rs1090、WouR较低而Fs50较高。ROC曲线显示Fs50> -2.64、Rs50<7.08、AUC<39761.7050、WinR<101.7、WouR<474.52为预测ITBLs的截断值。

要点

  • ITBLs组超声造影动态血管模式曲线为负向波,正常胆道组为正向波。
  • Fs50> -2.64预测ITBLs的AUC为0.816,敏感度0.846、特异度0.607。
  • Rs50<7.08、AUC<39761.7050、WinR<101.7、WouR<474.52的AUC分别为0.853、0.911、0.756、0.700。

核心结论

  • 超声造影定量参数IMAX、Rs50、AUC、WinAUC、WinR、Rs1090、WouR和Fs50有助于预测ITBLs并提高诊断可重复性,这些参数的阈值有助于肝移植术后缺血型胆道病变的早期诊断。

研究设计与样本

  • 前瞻性研究,纳入2020年6月25日至2022年12月28日于首都医科大学附属北京友谊医院行肝移植及静脉超声造影的患者,经MRCP、ERCP或PTC诊断为ITBLs者15例,正常胆道移植肝30例为对照组,采用SonoLiver软件定量分析造影图像,SPSS 25.0分析数据。

关键影像表现/征象

  • ITBLs组动态血管模式曲线为负向波,正常胆道组为正向波。
  • 与正常胆道组相比,ITBLs组IMAX、Rs50、AUC、WinAUC、WinR、Rs1090和WouR较低,Fs50较高。
  • 两组间RT、TTP、FHT、mTT、FT、WioAUC(WinAUC+WouAUC)和WouAUC差异无统计学意义(P>0.05)。

诊断标准与关键数值

  • Fs50> -2.64预测ITBLs的AUC为0.816(95%CI: 0.683-0.949),敏感度0.846、特异度0.607。
  • Rs50<7.08预测ITBLs的AUC为0.853(95%CI: 0.728-0.979)。
  • AUC<39761.7050预测ITBLs的AUC为0.911(95%CI: 0.783-1.000)。
  • WinR<101.7预测ITBLs的AUC为0.756(95%CI: 0.615-0.896)。
  • WouR<474.52预测ITBLs的AUC为0.700(95%CI: 0.536-0.864)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To explore the evaluation value of contrast enhanced ultrasound (CEUS) quantitative parameters in ischemic-type biliary lesions after liver transplantation to assist its early-diagnosis.

METHODS: Patients who underwent liver transplantation and intravenous CEUS at Beijing Friendship Hospital, Capital Medical University from June 25, 2020 to December 28, 2022 and were diagnosed with Ischemic-type biliary lesions (ITBLs) by Magnetic Resonance Cholangiopancreatography (MRCP) or Endoscopic Retrograde Cholangiopancreatography (ERCP) or Percutaneous Transhepatic Cholangiography (PTC) were prospectively enrolled. SonoLiver software was used to quantitatively analyze the contrast images, transplanted livers with normal biliary tracts as the control group. SPSS 25.0 software was used to analyze the data.

RESULTS: There was a total of 35 patients enrolled in the study, and 15 ITBLs and 30 normal biliary tract of transplanted livers, respectively. The dynamic vascular patterns (DVP) curve of the ITBLs group was negative wave, while the DVP curve of the normal biliary tract group was positive wave. Compared with the patients with normal biliary tract, the Maximum intensity (IMAX), Rise slope 50% (Rs50), Area under curve (AUC), Area under curve in Wash-in phase (WinAUC), Wash in Rate (WinR), Rise slope 10-90% (Rs1090), and Wash out Rate (WouR) of the ITBLs group were lower, while the Fall slope (Fs50) was higher. There was no significant difference in Rise time (RT), Time to Peak (TTP), Fall half time (FHT), Mean transit time (mTT), Fall time (FT), WioAUC ((WioAUC = WinAUC + WouAUC)), and Area under curve in Wash-out phase (WouAUC) between the two groups (P > 0.05). The ROC curve results showed that Fs50 > -2.64 was the cutoff value for predicting ITBLs, with an area under the curve of 0.816 (95%CI: 0.683-0.949), and a sensitivity and specificity of 0.846 and 0.607; Rs50 < 7.08, AUC < 39761.7050, WinR < 101.7 and WouR < 474.52 were the cutoff values for predicting ITBLs, with areas under the curve of 0.853 (95%CI: 0.728-0.979), 0.911 (95%CI: 0.783-1.000), 0.756 (95%CI: 0.615-0.896) and 0.700 (95%CI: 0.536-0.864).

CONCLUSION: The quantitative parameters of CEUS imaging, such as IMAX, Rs50, AUC, WinAUC, WinR, Rs1090, WouR, and Fs50, are helpful in predicting ITBLs and improving the reproducibility of diagnosis. The threshold of these quantitative parameters will aid in the early diagnosis of ischemic-type biliary lesions after liver transplantation.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。