文献速递腹部技术与安全CTMR

影像组学预测结直肠癌神经周围侵犯的系统评价与Meta分析

Radiomics for prediction of perineural invasion in colorectal cancer: a systematic review and meta-analysis.
PubMed 文献 · Abdom Radiol (NY) · 2025-01-22

该系统评价与Meta分析纳入12项研究共2853例患者,其中10项进入Meta分析,评估影像组学模型预测结直肠癌神经周围侵犯的诊断准确性;训练队列汇总敏感度0.74、特异度0.85、AUC 0.87,验证队列敏感度0.65、特异度0.85、AUC 0.84,提示中等至良好的诊断准确性,但研究间存在显著异质性。

要点

  • 影像组学模型预测结直肠癌神经周围侵犯的验证队列汇总敏感度0.65、特异度0.85、AUC 0.84。
  • 训练队列汇总敏感度0.74、特异度0.85、AUC 0.87,验证队列敏感度较训练队列低。
  • 纳入研究METRICS评分65.8%至85.1%,总体平均67.25%,方法学质量良好。

核心结论

  • 影像组学模型作为无创工具预测结直肠癌神经周围侵犯显示出前景,具有中等至良好的诊断准确性,但受回顾性数据、地理集中于中国及方法学差异等局限,需进一步研究。

研究设计与样本

  • 系统评价与Meta分析,检索PubMed、Embase和Web of Science截至2024年7月28日的文献,纳入12项研究共2853例患者,其中10项进入Meta分析,采用QUADAS-2和METRICS工具评估纳入研究质量。

诊断标准与关键数值

  • 训练队列汇总敏感度0.74(95%CI 0.63-0.82)、特异度0.85(95%CI 0.79-0.90)、AUC 0.87(95%CI 0.63-0.82);验证队列敏感度0.65(95%CI 0.57-0.72)、特异度0.85(95%CI 0.81-0.89)、AUC 0.84(95%CI 0.81-0.87)。

临床应用与阅片要点

  • 作者认为影像组学模型作为无创工具预测结直肠癌神经周围侵犯显示出前景,具有中等至良好的诊断准确性;作者建议未来研究应关注前瞻性设计、方法学标准化及整合先进机器学习技术。

局限性

  • 研究依赖回顾性数据。
  • 数据地理集中于中国。
  • 存在方法学差异。
  • 研究间敏感度和特异度估计存在显著异质性。
  • 作者指出需进一步研究,未来应关注前瞻性设计、方法学标准化及整合先进机器学习技术。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Perineural invasion (PNI) in colorectal cancer (CRC) is a significant prognostic factor associated with poor outcomes. Radiomics, which involves extracting quantitative features from medical imaging, has emerged as a potential tool for predicting PNI. This systematic review and meta-analysis aimed to evaluate the diagnostic accuracy of radiomics models in predicting PNI in CRC.

METHODS: A comprehensive literature search was conducted across PubMed, Embase, and Web of Science for studies published up to July 28, 2024. Inclusion criteria focused on studies using radiomics models to predict PNI in CRC with sufficient data to construct diagnostic accuracy metrics. The quality of the included studies was assessed using QUADAS-2 and METRICS tools. Pooled estimates of sensitivity, specificity, and area under the curve (AUC) were calculated. Subgroup analyses were performed based on imaging modalities, segmentation methods, and other variables.

RESULTS: Twelve studies comprising 2853 patients were included in the systematic review, with ten studies contributing to the meta-analysis. The pooled sensitivity and specificity for radiomics models in predicting PNI were 0.74 (95% CI: 0.63-0.82) and 0.85 (95% CI: 0.79-0.90), respectively, in the training cohorts. In the validation cohorts, the sensitivity was 0.65 (95% CI: 0.57-0.72), and specificity was 0.85 (95% CI: 0.81-0.89). The AUC was 0.87 (95% CI: 0.63-0.82) for the training cohorts and 0.84 (95% CI: 0.81-0.87) for the validation cohorts, indicating good diagnostic accuracy. The METRICS scores for the included studies ranged from 65.8 to 85.1%, with an overall average score of 67.25%, reflecting good methodological quality. However, significant heterogeneity was observed across studies, particularly in sensitivity and specificity estimates.

CONCLUSION: Radiomics models show promise as a non-invasive tool for predicting PNI in CRC, with moderate to good diagnostic accuracy. However, the current study's limitations, including reliance on retrospective data, geographic concentration in China, and methodological variability, suggest that further research is needed. Future studies should focus on prospective designs, standardization of methodologies, and the integration of advanced machine-learning techniques to improve the clinical applicability and reliability of radiomics models in CRC management.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Tang N, Pan S, Zhang Q, et al. Radiomics for prediction of perineural invasion in colorectal cancer: a systematic review and meta-analysis. Abdom Radiol (NY). 2025. PMID: 39841228. doi:10.1007/s00261-024-04713-x

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。