脐动脉搏动指数参考标准的比较
该研究为前瞻性研究的二次分析,纳入207例26至36周单胎高危妊娠,比较四种脐动脉搏动指数参考标准预测小于胎龄儿、不良新生儿结局及产科并发症的准确性。结果显示,各标准预测准确性均较差且相似(AUC 0.55–0.60),目前无法推荐某一特定标准优于其他标准,需更大规模试验进一步研究。
要点
- 四种UA-PI参考标准预测小于胎龄儿的AUC仅为0.55至0.56,准确性较差。
- 各标准预测不良新生儿结局的AUC为0.57至0.60,预测产科并发症的AUC均为0.55。
- 目前无法推荐某一特定UA-PI参考标准优于其他标准。
核心结论
- 所评估的UA-PI参考标准对小于胎龄儿、不良新生儿结局及产科并发症的预测能力均较差,目前无法推荐某一特定标准优于其他标准,需更大规模试验回答该研究问题。
研究设计与样本
- 前瞻性研究的二次分析,纳入207例26至36周经超声评估胎儿生长的单胎妊娠,估计胎儿体重或腹围小于第20百分位且有UA-PI测量值,排除染色体异常、先天畸形及无分娩信息者。
诊断标准与关键数值
- 以UA-PI大于第95百分位为异常,分别采用Acharya等、INTERGROWTH-21st项目、胎儿医学基金会及Parra-Cordero等的参考标准;预测小于胎龄儿的AUC为0.55至0.56,预测不良新生儿结局的AUC为0.57至0.60,预测产科并发症的AUC均为0.55,各标准间相似且差异有统计学意义但预测准确性差。
临床应用与阅片要点
- 作者指出目前无法推荐某一特定UA-PI参考标准优于其他标准,需更大规模试验回答该研究问题。
局限性
- 本文为前瞻性研究的二次分析。
- 需更大规模试验回答该研究问题。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To compare the accuracy of four published reference standards for the umbilical artery pulsatility index (UA-PI) in predicting small-for-gestational age (SGA), adverse neonatal outcomes and obstetric complications in pregnancies at risk for fetal growth restriction.
METHODS: This was a secondary analysis of a prospective study of singleton pregnancies that underwent fetal growth assessment by ultrasound between 26 and 36 weeks' gestation. Pregnancies with estimated fetal weight or abdominal circumference < 20th percentile with UA-PI measurements available were included. We excluded fetuses with chromosomal anomaly or congenital malformation and those without delivery information. The predictive ability of UA-PI > 95th percentile according to the reference standards of Acharya et al., the INTERGROWTH-21st Project, the Fetal Medicine Foundation and Parra-Cordero et al. for SGA, a composite of adverse neonatal outcomes and a composite of obstetric complications was compared using the area under the receiver-operating-characteristics curve (AUC). Sensitivity, specificity and positive and negative predictive values were calculated.
RESULTS: Of the 1054 pregnancies that underwent fetal growth evaluation by ultrasound, 207 were included in our analysis. SGA, adverse neonatal outcomes and obstetric complications were diagnosed in 94 (45.4%), 50 (24.2%) and 69 (33.3%) cases, respectively. All reference standards had similar and statistically significant but poor predictive accuracy for SGA (AUC of 0.55 to 0.56), adverse neonatal outcomes (AUC of 0.57 to 0.60) and obstetric complications (AUC of 0.55 for all).
CONCLUSIONS: The reference standards for UA-PI evaluated herein have poor predictive ability for SGA, adverse neonatal outcomes and obstetric complications. At present, no particular UA-PI reference standard can be recommended over others. Larger trials are needed to answer this research question. © 2024 International Society of Ultrasound in Obstetrics and Gynecology.